nyban1
You are here: Home » Systems » Emergency Shutdown System » Electrical Protection and Control » Schneider A9F79116 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 16A, C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Leave Us A Message

loading

Schneider A9F79116 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 16A, C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

  • Schneider

  • A9F79116

  • IN STOCK

  • T/T

  • XIAMEN

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The A9F79116 is a 16‑ampere, single‑pole miniature circuit breaker from Schneider Electric’s Acti9 iC60N range, designed with a C‑curve tripping characteristic (magnetic threshold at 8 × In). The C‑curve strikes a practical balance between overload protection and immunity to moderate inrush currents, making it a natural fit for general‑purpose distribution circuits – including lighting networks, receptacle outlets, small power tools, and control panels – across commercial buildings, light industrial sites, and residential complexes. This MCB is certified to both the industrial standard EN/IEC 60947‑2 and the residential standard EN/IEC 60898‑1, offering a versatile solution for projects that require cross‑standard acceptance. It delivers a dependable ultimate breaking capacity of 10 kA at 220‑240 V AC (per IEC 60947‑2) and 6 kA at 230 V AC (per IEC 60898‑1), ensuring robust fault interruption in diverse grid conditions. The device incorporates the well‑known VisiTrip indicator window, which visually flags the tripped pole to accelerate fault diagnosis, and the VisiSafe green strip that provides a visible and unambiguous confirmation of contact opening – an essential safety feature for any downstream maintenance activity. Its quick‑make/quick‑break mechanism, independent of the toggle position, guarantees consistent performance over 10,000 electrical and 20,000 mechanical cycles. With a compact 18 mm width (2 modular pitches) and DIN‑rail clip‑on mounting, it optimises panel space. The double‑tunnel terminals accept rigid conductors up to 25 mm² and flexible up to 16 mm², with a 2 N·m tightening torque. The breaker offers IP20 protection at the terminals and IP40 when housed in an enclosure, operates from -35 °C to +70 °C, and is built with halogen‑free plastics and PVC‑free materials, achieving a 54% recyclability rate and a total lifecycle carbon footprint of 14 kg CO₂ eq.

Parameter

Details

General

Product Model

A9F79116

Range

Acti9

Product Name

Acti9 iC60

Device Short Name

iC60N

Device Application

Distribution

Poles Description

1P

Number of Protected Poles

1

Rated Current (In)

16 A

Network Type

AC / DC

Trip Unit Technology

Thermal‑magnetic

Tripping Curve

C

Magnetic Tripping Limit

8 x In ± 20%

Suitability for Isolation

Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2)

Utilisation Category

Category A (EN/IEC 60947‑2)

Breaking Capacity (Icu)

– EN/IEC 60947‑2 (AC)

36 kA at 12…60 V AC 50/60 Hz
20 kA at 100…133 V AC 50/60 Hz
10 kA at 220…240 V AC 50/60 Hz

– EN/IEC 60947‑2 (DC)

15 kA at 12…60 V DC
10 kA at 60…72 V DC

– EN/IEC 60898‑1 (AC)

6,000 A at 230 V AC 50/60 Hz

Service Breaking Capacity (Ics)

– EN/IEC 60947‑2 (AC)

27 kA (75% x Icu) at 12…60 V AC
15 kA (75% x Icu) at 100…133 V AC
7.5 kA (75% x Icu) at 220…240 V AC

– EN/IEC 60947‑2 (DC)

15 kA (100% x Icu) at 12…60 V DC
10 kA (100% x Icu) at 60…72 V DC

Limitation Class

Class 3 (EN/IEC 60898‑1)

Rated Operational Voltage (Ue)

12…60 V AC 50/60 Hz
100…133 V AC 50/60 Hz
220…240 V AC 50/60 Hz
12…60 V DC
60…72 V DC

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz (EN/IEC 60947‑2)

Rated Impulse Withstand Voltage (Uimp)

6 kV (EN/IEC 60947‑2)

Network Frequency

50/60 Hz

Durability

Mechanical Durability

20,000 cycles

Electrical Durability

10,000 cycles

Contact Position Indicator

Yes (toggle)

Local Signalling

Trip indicator (VisiTrip)

Mounting & Physical

Mounting Mode

Clip‑on (35 mm DIN rail)

Removable Comb Busbar

Installed; compatible top or bottom

Connection Pitch

18 mm between devices

Number of Pitches

2 (18 mm total width)

Width

18 mm

Height

85 mm

Depth

78.5 mm

Product Weight

0.215 kg

Colour

White (RAL9003)

Terminals & Connections

Connection Type

Single terminal (top or bottom), double tunnel

Rigid Conductor (copper)

1…25 mm²

Flexible Conductor (copper)

1…16 mm²

Flexible with Ferrule (copper)

1…10 mm²

With Ring Terminal (Cu/Al)

Via accessory

Wire Stripping Length

14 mm (top or bottom)

Tightening Torque

2 N·m (top or bottom)

Earth‑leakage Protection

Without (separate add‑on block required)

Environmental & Protection Ratings

Standards Compliance

EN/IEC 60947‑2, EN/IEC 60898‑1

IP Degree (terminals)

IP20 (IEC 60529)

IP in Enclosure

IP40 (Insulation class II)

Pollution Degree

3 (EN/IEC 60947‑2)

Overvoltage Category

IV

Tropicalisation

2 (IEC 60068‑1)

Relative Humidity

95% at 55°C

Operating Altitude

0…2000 m

Operating Temperature

-35°C … +70°C

Storage Temperature

-40°C … +85°C

Sustainability & Compliance

Halogen‑free (plastic parts)

Yes

PVC‑free

Yes

Silicone‑free

Not specified (assumed No based on typical series)

Recyclability Potential

54%

EU RoHS Directive

Compliant

REACH SVHC

Contains SVHC above threshold

SCIP Number

26F71d1‑98cf‑4280‑8725‑455b9a6b2fb9

Packaging with recycled cardboard

Yes

Packaging without single‑use plastic

Yes

WEEE Label

Required for EU disposal (separate collection)

Repair / Take‑back

No / No

Logistics

Country of Origin

Not specified (typically Bulgaria for iC60 series)

Warranty

18 months

Package 1 (Single unit)

1 pc; H 1.8 cm × W 7.5 cm × L 9.5 cm; weight 109 g

Package 2 (Box of 12)

12 units; H 8.0 cm × W 9.5 cm × L 22.0 cm; weight 1.369 kg

Package 3 (Pallet of 132)

H 30 cm × W 30 cm × L 40 cm; weight 15.64 kg

Carbon Footprint (Lifecycle)

Total

14 kg CO₂ eq.

Manufacturing (A1‑A3)

0.8 kg CO₂ eq.

Distribution (A4)

0 kg CO₂ eq.

Installation (A5)

0 kg CO₂ eq.

Use Phase (B2, B3, B4, B6)

13 kg CO₂ eq.

End‑of‑life (C1‑C4)

0.3 kg CO₂ eq.

Environmental Disclosure

Product Environmental Profile available


Previous: 
Next: 

Related Products

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.