nyban1
You are here: Home » Systems » Emergency Shutdown System » Electrical Protection and Control » Schneider A9F79150 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 50A, C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Leave Us A Message

loading

Schneider A9F79150 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 50A, C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

  • Schneider

  • A9F79150

  • IN STOCK

  • T/T

  • XIAMEN

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The A9F79150 is a 50‑ampere, single‑pole miniature circuit breaker from Schneider Electric’s Acti9 iC60N series, engineered with a C‑curve tripping characteristic (magnetic threshold at 8 × In). This C‑curve design makes it an excellent choice for protecting circuits with moderate inrush currents – such as lighting banks, general socket outlets, control panels, and small motor feeders – where a balance between overload protection and nuisance‑trip avoidance is critical. As part of the iC60N family, this MCB delivers reliable breaking capacities: 10 kA at 220‑240 V AC per the industrial EN/IEC 60947‑2 standard, and 6 kA at 230 V AC for residential applications under EN/IEC 60898‑1, making it equally suitable for commercial distribution boards and industrial sub‑distribution. The device incorporates the intuitive VisiTrip fault‑finder, which highlights the tripped pole to accelerate troubleshooting, and the VisiSafe green strip that gives unequivocal visual proof of contact separation – an essential safety feature before performing downstream maintenance. Its fast‑make/quick‑break mechanism, independent of handle position, ensures consistent performance over 10,000 electrical and 20,000 mechanical cycles. Despite its high 50 A rating, the breaker maintains a compact 18 mm width (2 modular pitches) and clips onto DIN rails, optimising panel density. The terminals accept rigid conductors up to 35 mm² and flexible up to 25 mm², with a robust 3.5 N·m torque for secure connections. It offers IP20 protection at the terminals and IP40 when enclosed in a modular cabinet, with a wide operating temperature range from -35 °C to +70 °C. On the sustainability front, the product is PVC‑free and achieves 54% recyclability, though it does contain halogen above thresholds; its full lifecycle carbon footprint is quantified at 23 kg CO₂ eq., reflecting Schneider Electric’s transparent environmental reporting.

Parameter

Details

General

Product Model

A9F79150

Range

Acti9

Product Name

Acti9 iC60

Device Short Name

iC60N

Device Application

Distribution

Poles Description

1P

Number of Protected Poles

1

Rated Current (In)

50 A

Network Type

AC / DC

Trip Unit Technology

Thermal‑magnetic

Tripping Curve

C

Magnetic Tripping Limit

8 x In ± 20%

Suitability for Isolation

Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2)

Utilisation Category

Category A (EN/IEC 60947‑2)

Breaking Capacity (Icu)

– EN/IEC 60947‑2 (AC)

36 kA at 12…60 V AC 50/60 Hz
20 kA at 100…133 V AC 50/60 Hz
10 kA at 220…240 V AC 50/60 Hz

– EN/IEC 60947‑2 (DC)

15 kA at 12…60 V DC
10 kA at 60…72 V DC

– EN/IEC 60898‑1 (AC)

6,000 A at 230 V AC 50/60 Hz

Service Breaking Capacity (Ics)

– EN/IEC 60947‑2 (AC)

27 kA (75% x Icu) at 12…60 V AC
15 kA (75% x Icu) at 100…133 V AC
7.5 kA (75% x Icu) at 220…240 V AC

– EN/IEC 60947‑2 (DC)

15 kA (100% x Icu) at 12…60 V DC
10 kA (100% x Icu) at 60…72 V DC

Limitation Class

Class 3 (EN/IEC 60898‑1)

Rated Operational Voltage (Ue)

12…60 V AC 50/60 Hz
100…133 V AC 50/60 Hz
220…240 V AC 50/60 Hz
12…60 V DC
60…72 V DC

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz (EN/IEC 60947‑2)

Rated Impulse Withstand Voltage (Uimp)

6 kV (EN/IEC 60947‑2)

Network Frequency

50/60 Hz

Durability

Mechanical Durability

20,000 cycles

Electrical Durability

10,000 cycles

Contact Position Indicator

Yes (toggle)

Local Signalling

Trip indicator (VisiTrip)

Mounting & Physical

Mounting Mode

Clip‑on (35 mm DIN rail)

Removable Comb Busbar

Installed; compatible top or bottom

Connection Pitch

18 mm between devices

Number of Pitches

2 (18 mm total width)

Width

18 mm

Height

85 mm

Depth

78.5 mm

Product Weight

0.215 kg

Colour

White (RAL9003)

Terminals & Connections

Connection Type

Single terminal (top or bottom), double tunnel

Rigid Conductor (copper)

1…35 mm²

Flexible Conductor (copper)

1…25 mm²

Flexible with Ferrule (copper)

1…25 mm²

With Ring Terminal (Cu/Al)

Via accessory

Multiple Conductors (with accessory)

Up to 3 x 16 mm² rigid or 3 x 10 mm² flexible

Wire Stripping Length

14 mm (top or bottom)

Tightening Torque

3.5 N·m (top or bottom)

Earth‑leakage Protection

Without (separate block required)

Environmental & Protection Ratings

Standards Compliance

EN/IEC 60947‑2, EN/IEC 60898‑1

IP Degree (terminals)

IP20 (IEC 60529)

IP in Enclosure

IP40 (Insulation class II)

Pollution Degree

3 (EN/IEC 60947‑2)

Overvoltage Category

IV

Tropicalisation

2 (IEC 60068‑1)

Relative Humidity

95% at 55°C

Operating Altitude

0…2000 m

Operating Temperature

-35°C … +70°C

Storage Temperature

-40°C … +85°C

Sustainability & Compliance

Halogen‑free status

Product contains halogen above thresholds (not halogen‑free)

PVC‑free

Yes

Silicone‑free

No

Recyclability Potential

54%

EU RoHS Directive

Compliant

REACH SVHC

Contains SVHC above threshold

SCIP Number

26ff71d1‑98cf‑4280‑8725‑455b9a6b2fb9

Packaging with recycled cardboard

Yes

Packaging without single‑use plastic

Yes

WEEE Label

Required for EU disposal (separate collection)

Repair / Take‑back

No / No

Logistics

Country of Origin

Not specified (typically BG for iC60 series)

Warranty

18 months

Package 1 (Single unit)

1 pc; H 7.5 cm × W 1.8 cm × L 9.5 cm; weight 129 g

Package 2 (Box of 12)

12 units; H 8.5 cm × W 10.0 cm × L 22.0 cm; weight 1.600 kg

Package 3 (Pallet)

36 units; H 30 cm × W 30 cm × L 40 cm; weight 5.291 kg

Carbon Footprint (Lifecycle)

Total

23 kg CO₂ eq.

Manufacturing (A1‑A3)

0.8 kg CO₂ eq.

Distribution (A4)

0 kg CO₂ eq.

Installation (A5)

0 kg CO₂ eq.

Use Phase (B2, B3, B4, B6)

22 kg CO₂ eq.

End‑of‑life (C1‑C4)

0.4 kg CO₂ eq.

Environmental Disclosure

Product Environmental Profile available


Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.