  • Schneider

  • A9V31263

  • IN STOCK

  • T/T

  • XIAMEN

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The A9V31263 is a 2‑pole add‑on residual current device (RCD) from Schneider Electric’s Acti9 Vigi iC60 range, designed to be mounted alongside Acti9 iC60 or Reflex iC60 miniature circuit breakers (MCBs) to provide comprehensive earth‑leakage protection in final distribution circuits. Rated at 63 A with a sensitivity of 30 mA and instantaneous tripping, this unit offers fast and reliable disconnection in the event of a ground fault, greatly enhancing personnel safety and equipment protection against indirect contact. Its A‑SI type (Super Immunised) classification ensures high immunity to unwanted tripping caused by transient currents, such as those from lightning surges or switching events, making it particularly suitable for environments with frequent electrical disturbances. Operating at 230‑240 V AC (50/60 Hz) and compliant with both EN/IEC 61009‑1 and 61009‑2‑1 standards, the device is voltage‑independent, meaning it does not rely on the supply voltage for tripping, ensuring operation even in degraded grid conditions. The unit clips onto a DIN rail and connects directly to the MCB via screw terminals, simplifying panel assembly. With a compact 72 mm width (4 modular pitches) and a height of 91 mm, it fits neatly into standard distribution boards. The integrated trip indicator provides clear local signalling for rapid fault identification. The A9V31263 is built with halogen‑free plastic parts, is PVC‑free, and carries Green Premium compliance, reflecting Schneider Electric’s environmental stewardship. Its total lifecycle carbon footprint is quantified at 6 kg CO₂ eq., with a recyclability potential of 28%, and the product is eligible for take‑back at end‑of‑life.

Parameter

Details

General

Product Range

Acti9

Product Name

Acti9 Vigi iC60

Device Short Name

Vigi iC60

Product Type

Add‑on residual current device (RCD)

Poles Description

2P

Rated Current (In)

63 A

Earth‑leakage Sensitivity

30 mA

Earth‑leakage Protection Time Delay

Instantaneous

Earth‑leakage Protection Type

Type A‑SI (Super Immunised)

Electrical

Network Type

AC

Network Frequency

50/60 Hz

Rated Operational Voltage (Ue)

230…240 V AC 50/60 Hz (conforming to EN/IEC 61009‑1 and 61009‑2‑1)

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz (IEC 60947‑2)

Rated Impulse Withstand Voltage (Uimp)

6 kV (IEC 60947‑2)

Residual Current Tripping Technology

Voltage‑independent

Electromagnetic Compatibility

8/20 μs impulse withstand, 3000 A (IEC 61009‑1)

Standards & Compliance

Standards

EN/IEC 61009‑1, EN/IEC 61009‑2‑1

Green Premium

Yes (RoHS compliant by exemption, REACh SVHC above threshold)

SCIP Number

B078722f‑7853‑4e1e‑a05b‑29638f57b0ab

POPs

No POPs

Halogen‑free (plastic parts)

Yes

PVC‑free

Yes

Compatibility & Mounting

Compatible Ranges

Acti9 iC60, Acti9 Reflex iC60

Device Location in System

Outgoer

Mounting Mode

Clip‑on (DIN rail)

Electrical Connection to MCB

By screws

Comb Busbar Compatibility

Bottom: YES

Modular Pitches

4 (72 mm width)

Physical Dimensions

Width

72 mm (4 pitches of 9 mm)

Height

91 mm

Depth

Not specified, but typical for series

Terminals & Wiring

Connection Type

Single terminal (bottom)

Rigid Conductor (without cable end)

1…35 mm² (from PDF: 1.35 mm² but likely 1…35)

Flexible Conductor (without cable end)

1…25 mm²

Flexible with Ferrule

1…25 mm²

Wire Stripping Length

14 mm (bottom)

Tightening Torque

3.5 N·m (bottom)

Environmental Ratings

IP Degree of Protection

IP20 (terminals) / IP40 (in modular enclosure) (IEC 60529)

Pollution Degree

3 (IEC 60947‑2)

Operating Temperature

-25…60 °C

Storage Temperature

-40…85 °C

Packaging & Logistics

Package 1 (Single Unit)

1 pc; H 8.5 cm × W 7.8 cm × L 11.5 cm; weight 188 g

Package 2 (Box of 27)

27 units; H 30 cm × W 30 cm × L 40 cm; weight 5.574 kg

Sustainability Metrics

Total Lifecycle Carbon Footprint

6 kg CO₂ eq.

– Manufacturing (A1‑A3)

1 kg CO₂ eq.

– Distribution (A4)

0 kg CO₂ eq.

– Installation (A5)

0 kg CO₂ eq.

– Use Phase (B2, B3, B4, B6)

4 kg CO₂ eq.

– End‑of‑life (C1‑C4)

0.3 kg CO₂ eq.

Recyclability Potential

28%

End‑of‑life Take‑back

Yes

WEEE Label

Required (separate collection in EU)


Previous: 
Next: 

Related Products

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.