GSI127 Model 244-127-000-017-A1-B02 is a highly specialized Galvanic Separation and Signal Conversion Unit optimized for specific industrial vibration monitoring signal chains. This model is not a generic configuration but is precisely calibrated for "plug-and-play" compatibility with standard current-output sensors and signal conditioners featuring a 12mA quiescent current. Its core value lies in providing a terminal solution—integrating safe isolation, precise power supply, linear signal conversion, and hazardous area certification—for measurement chains represented by the vibro-meter non-diagnostics IPC707 charge amplifier.


This product is a precision interface device within Meggitt's sensing systems portfolio, designed to meet the stringent electrical environmental and safety standards of industrial sites. It addresses core challenges in long-distance signal transmission, including ground loop interference, high-voltage threats, and safe power supply for equipment in hazardous areas, ensuring the highest integrity and reliability of the signal path from sensor to monitoring system. Choosing the B02 model means selecting a standardized component tailored for standard vibration monitoring links, significantly reducing system integration complexity and guaranteeing measurement baseline accuracy.

2. Model Decoding and Exclusive Configuration Details

Each field in the model number 244-127-000-017-A1-B02 defines its irreplaceable application characteristics:

  • GSI127: Base product family code, representing "Galvanic Separation Unit Type 127".

  • A1: Environmental Safety Certification Code. This indicates the unit is an Explosion-Proof Certified Version. The main housing is grey, but the top pluggable screw-terminal connector for the sensor side is a conspicuous blue, clearly identifying its connection interface to equipment in hazardous areas, complying with explosion-proof installation standards.

  • B02: Core Electrical Function Code. This is the soul of this model, precisely defining the following exclusive parameter set:

    1. Sensor-Side Power Supply Mode: Provides a 20 VDC ±1% precision regulated power supply, specifically designed to drive vibro-meter® charge amplifiers and similar electronic conditioners.

    2. Signal Transfer Function: Employs Current-to-Voltage (I/V) Conversion mode, suitable for long-distance, noise-immune transmission of 2-wire 4-20mA current signals.

    3. Conversion Sensitivity: Fixed at 1.000 V/mA, with an accuracy of ±1%. This means for every 1mA change in sensor-side current, the monitor side produces a precise 1.000V voltage change.

    4. Critical Zero-Point Configuration: The output offset voltage (zero point) is preset to 7.00 VDC ±200 mV. This voltage precisely corresponds to a quiescent current of 12.00 mA DC on the sensor-side signal loop. This setting is optimized for the standard operating point of the non-diagnostics IPC707 charge amplifier. When the IPC707 has zero acceleration input, its standard output current is 12mA, at which point the GSI127 B02 output is exactly 7VDC, establishing an accurate zero-reference for the monitoring system.

3. Typical Application Scenarios & System Integration Scheme

The GSI127 Model 244-127-000-017-A1-B02 is the designated and optimal interface unit for the following standard measurement chain:

Application Scenario: Absolute bearing vibration monitoring for industrial rotating machinery (turbines, compressors, pumps, fans).

Standard Signal Chain Composition:

  1. Vibration Sensing End: CAxxx series piezoelectric accelerometer (e.g., CA134, CA201) mounted on the bearing housing.

  2. Signal Local Conversion End: Non-diagnostics IPC707 Charge Amplifier. It converts the high-impedance charge signal from the accelerometer into a noise-immune 2-wire 4-20mA current signal. Its nominal zero-acceleration output current is 12mA.

  3. Long-Distance Transmission & Interface End: GSI127 A1-B02 Unit. Located in the control cabinet within the safe area.

    • Function 1 (Power Supply): Provides 20 VDC operating power to the remote IPC707 via a two-wire cable.

    • Function 2 (Signal Reception & Conversion): Receives the 4-20mA current signal from the IPC707 and linearly converts it to a 2-10 VDC voltage signal (corresponding to vibration amplitude).

    • Function 3 (Isolation & Safety): Provides 4 kV electrical isolation and, with its [ia Ga] level intrinsically safe output, acts as a safety barrier, ensuring energy limitation for the hazardous area (sensor location).

  4. Monitoring System End: VM600, MMS, or other DCS/PLC system analog input cards receive the 2-10 VDC voltage signal from the GSI127.


Why B02 Must Be Chosen Over Other Models?

  • Compared to B01 (Zero @5mA): If B01 is used for a standard IPC707 chain, the GSI127 would output 5V instead of 7V at rest. The monitoring system would misinterpret this as a negative vibration offset equivalent to 2mA (i.e., 2V), causing all readings to be erroneous.

  • Compared to B03 (Zero @17.5mA): This is designed for the IPC707 with diagnostics (its quiescent output is 13mA, corresponding to 8V). Using it with a standard IPC707 would create a larger baseline error.

  • Compared to B04/B21 (Voltage-to-Voltage Mode): Suitable for voltage-output sensors (e.g., some IQSxxx or IPC707 with voltage output), completely incompatible with current transmission chains.

Therefore, 244-127-000-017-A1-B02 is the standardized, high-precision matching interface for the classic vibration monitoring combination: "CAxxx Accelerometer + Non-Diagnostics IPC707".

4. Installation, Wiring & Commissioning Guide

  1. Installation: Clip the unit onto a standard TH35 DIN rail inside the control cabinet. Orient the blue-marked top terminal area towards the incoming sensor cables.

  2. Power Wiring: Connect the 18-30 VDC power supply to the designated power pins on the unit's bottom "Monitor Side" terminals (refer to specific wiring diagram).

  3. Sensor-Side Wiring (Critical):

    • Use twisted-pair shielded cable to connect the IPC707 to the GSI127's blue top terminals.

    • The cable shield must be properly grounded at a single point only, at the IPC707 housing. At the GSI127 end, the shield must be trimmed flush and insulated with tape; it must absolutely NOT be connected to the terminals or touch the housing. This is the golden rule to prevent ground loop noise.

    • Tighten the screws on the pluggable terminal block.

  4. Monitor-Side Wiring: Use ordinary twisted-pair wire to connect the signal output (2-10 VDC) from the bottom terminals to the monitoring system card. Shield handling should follow the monitoring system side requirements.

  5. Commissioning Verification:

    • Power up the system. With the machine at rest, measure the GSI127 monitor-side output with a multimeter.

    • The correct result should be: 7.00 VDC ±0.2V. This step is the primary standard for verifying the entire sensor chain (IPC707) is functioning correctly and the B02 model is the proper choice.

    • If the reading deviates significantly, check if the IPC707 is the "non-diagnostics" version corresponding to this model, or if there are issues with the sensor cable.


1. Electrical Characteristics & Performance Parameters

Item Specification Notes & B02 Model Analysis
General Power Input

Input Voltage Range 18 to 30 VDC 24 VDC operation recommended
No-Load Current Consumption ≤ 80 mA @24VDC
Full-Load Current Consumption ≤ 120 mA @24VDC (20mA load on sensor side)
Sensor-Side Interface (B02 Exclusive)

Supply Output 20 VDC ±1 VDC Constant Voltage Source (CP), powers signal conditioner
Output Impedance ≤ 30 Ω Low impedance output, suitable for driving current-type loads
Signal Input Dynamic Range 0 to 20 mA Covers standard 4-20mA signal with overhead/margin
Input Overload Protection Threshold 26 mA Provides safety margin, protects internal circuitry
Monitor-Side Output Interface

Output Voltage Range 2 to 20 VDC (load ≥10 kΩ) Corresponds to 0-20mA input; output is 7VDC for 12mA input
Output Impedance 20 Ω (short-circuit protected) Low impedance voltage output, strong drive capability
Power Supply Rejection Ratio (PSRR) ≥60 dB (10-400 Hz); ≥30 dB (400 Hz-100 kHz) Effectively suppresses power line noise
Output Offset Drift vs. Temp. ≤ 2 mV/°C Ensures long-term zero-point temperature stability
Output Sensitivity Drift vs. Temp. ≤ 50 ppm/°C Ensures temperature stability of conversion ratio
Output Residual Noise ≤ 3.5 μV RMS/√Hz Very low noise, ensures signal resolution
B02 Core Conversion Characteristics

Transfer Sensitivity 1 V/mA ±1% Precise current-to-voltage conversion ratio
Output Offset Voltage (Zero Point) 7 VDC ±200 mVDC Corresponds to 12.00 mA quiescent current on sensor side
Bandwidth (within ±0.5 dB) DC to 20 kHz Meets requirements of vast majority of mechanical vibration monitoring
Typical -3 dB Cut-off Frequency 30 kHz
Linearity Error < 0.2% of F.S. High linearity ensures conversion accuracy across full scale
Isolation & Safety Characteristics

Channel Isolation (Sensor/Monitor Side) 4 kV RMS (1 minute) Core feature to eliminate ground loops and block high-voltage hazards
Internal Isolation (Power Supply/Output) 50 V RMS Enables floating output, no external isolation power supply needed

2. Physical & Environmental Specifications

Item Specification
Operating Temperature Range 0 to +70°C
Storage Temperature Range -40 to +85°C
Operating/Storage Humidity ≤90%/≤95% RH, non-condensing (IEC 60068-2-30)
Vibration Resistance 1 g peak (5-35 Hz, 90 min/axis, IEC 60068-2-6)
Shock Resistance 6 g peak, 11ms half-sine, 3 shocks/axis (IEC 60068-2-27)
Housing Material & Color Polyamide (PA 66 GF 30). A1 Version: Grey housing, top (sensor-side) terminals in blue
Mounting Method Standard TH 35 (7.5 or 15) DIN Rail (EN 50022/IEC 60715)
Terminal Connections One pluggable screw-clamp terminal block (4 contacts each) on top and bottom
Wire Specifications IEC: 0.2 – 2.5 mm²; UL: 26 – 12 AWG
Weight Approx. 140 grams

3. Compliance & Certifications (A1 Explosion-Proof Version Exclusive)

Item Certification Details
Electromagnetic Compatibility (EMC) EN 61000-6-2:2005 (Immunity), EN 61000-6-4:2007+A1:2011 (Emission)
Electrical Safety EN 61010-1:2010
Environmental RoHS (2011/65/EU) Compliant
Market Access CE (EU), UKCA (UK), EAC (Eurasian Union) Declarations of Conformity
Explosion-Proof Certification (Core Advantage) ATEX: II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
IECEx: Ex nA [ia Ga] IIC T4 Gc
cCSAus (North America): Class I, Div. 2, Gr. A,B,C,D & Zone 2 AEx nA [ia Ga] IIC T4 Gc
KGS (Korea): Ex nA [ia] IIC T4
EAC (Russia): Ex nA [ia Ga] IIC T4 Gc
Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.