GSI127 Model 244-127-000-017-A2-B03 is Meggitt's top-tier configured galvanic separation unit launched for vibration monitoring applications in high-risk explosive environments that demand extremely high signal accuracy and system diagnostic capabilities. This model represents the perfect fusion of the A2 explosion-proof certification system and the B03 high-sensitivity current transmission mode, embodying the highest safety and technical standards for achieving intelligent, precise predictive maintenance in critical hazardous areas such as oil, chemical, and natural gas industries.
In potentially explosive atmospheres, traditional safety strategies often compromise some measurement performance. The GSI127 A2-B03 completely this notion. On one hand, through the stringent explosion-proof certification implied by the A2 option (such as intrinsic safety [ia Ga] or other high-level protection types), it ensures that neither the device itself nor the associated sensor loop can become an ignition source under any fault condition, meeting the safety requirements for powering equipment in Zone 2 and even Zone 0/1 areas. On the other hand, its B03 configuration provides an industry-leading conversion sensitivity of 3.2 V/mA, dramatically "amplifying" weak sensor current signals. This ensures high signal-to-noise ratio and high-resolution voltage signals are delivered to the monitoring system even after long-distance transmission, which is crucial for detecting the faint early signs of mechanical faults.
In short, the GSI127 A2-B03 merges the mandatory requirement for safety compliance with the forward-thinking need for monitoring precision. It is not only the "operating license" ensuring a plant's safe and legal operation but also the "performance accelerator" for enhancing equipment reliability and achieving intelligent predictive maintenance upgrades. Choosing this model equips the operational status of your most critical rotating equipment in the most dangerous areas with a "nerve ending" that combines the highest safety rating with optimal monitoring performance.
Every field in the model number 244-127-000-017-A2-B03 carries specific technical and safety commitments:
GSI127: Series base code, indicating its core functions: galvanic separation, power supply, and signal conversion.
A2: Environmental Safety Grade Code. This is the mandatory safety passport for entering hazardous areas.
Legal Implication: "A2" indicates the product has been designed and manufactured according to specific international standards (e.g., ATEX, IECEx) and has obtained formal certification for use in potentially explosive atmospheres.
Key Difference: Unlike general industrial versions or basic explosion-proof versions (which may have other codes), the certification certificate corresponding to A2 clearly specifies its type of protection (e.g., Ex nA, Ex ic, or Ex ia), Equipment Protection Level, temperature class, and strict conditions for safe use. Users must obtain and adhere to this certificate before installation.
Physical Identification: According to the data, the housing of the A2 version is completely grey, distinguishing it from the A1 version which has blue sensor-side terminals.
B03: High-Performance Electrical Configuration Code. This is the technical core enabling precise and intelligent monitoring.
Operating Mode: Provides a 20 VDC constant voltage source to the sensor side, operating in current input/voltage output mode.
Ultra-High Sensitivity: Conversion sensitivity is 3.2 V/mA ±1%. This is 3.2 times that of standard models (1 V/mA). For the same current change, the output voltage change is greater, maximizing the use of the backend acquisition card's range and significantly improving signal-to-noise ratio and the ability to detect minor fault signals.
Intelligent Diagnostic Zero Point: The output zero-point voltage is 8.00 VDC ±200 mV, corresponding to a 17.50 mA quiescent current on the sensor side. This zero-point design is specifically matched to the vibro-meter® IPC707 charge amplifier with diagnostics. This diagnostic IPC707 outputs 13 mA under normal conditions, resulting in a 8 VDC output from the GSI127 B03, establishing an accurate baseline for vibration monitoring. Simultaneously, its design reserves ample dynamic range for diagnostic alarm signals (where the current may surge towards 20mA or drop).
The GSI127 A2-B03 is the hub for "high-safety" and "high-intelligence" monitoring chains, typically applied in: Vibration protection and predictive maintenance systems for critical units like gas turbines and high-speed compressors on offshore platforms, in refineries, and natural gas compressor stations.
System Architecture Breakdown:
Perception Layer (Hazardous Area Zone 1):
Device: CAxxx series high-temperature accelerometer.
Function: Senses bearing vibration, outputs charge signal.
Intelligent Conversion Layer (Hazardous Area Zone 1 or Boundary):
Signal Conversion: Converts charge signal to 4-20mA current signal.
Health Diagnostics: Monitors sensor and cable integrity in real-time. Outputs 13 mA normally; outputs a specific current value (e.g., 3.8 mA or 21 mA) as an alarm code upon fault (e.g., open or short circuit).
Device: IPC707 Charge Amplifier with Diagnostics.
Function:
Safety Interface & Performance Enhancement Layer (Safe Area or Zone 2 Control Cabinet):
Safety Isolation: Provides 4 kV isolation and acts as an intrinsically safe associated apparatus. Its certified [ia Ga] output ensures absolute safety of energy delivered to the hazardous area.
High-Precision Conversion: With 3.2 V/mA sensitivity, converts the 13 mA zero-point to 8 VDC and the 20 mA full scale to ≈17.6 VDC, maximizing the use of the acquisition card's range.
Diagnostic Compatibility: Its zero-point design and wide dynamic range can clearly and unambiguously transmit the IPC707's diagnostic codes, enabling the monitoring system to distinguish between "high vibration" and "sensor fault".
Device: GSI127 244-127-000-017-A2-B03.
Function:
Monitoring Layer (Safe Area):
Device: VM600, MMS, or other systems.
Function: Receives high-quality voltage signals for vibration analysis, alarm generation, and interpretation of diagnostic information.
Why Must the A2-B03 Combination Be Chosen?
Only B03 (Not A2): Cannot meet the regulatory mandatory certification requirements for hazardous areas; system installation would be non-compliant.
Only A2 (Not B03): For example, using A2-B01, while safety compliant, would not match the diagnostic IPC707's 13mA zero-point (causing the 8V zero-vibration signal to be misinterpreted as an offset) and would have only 1 V/mA sensitivity, significantly degrading signal quality and diagnostic compatibility.
A2-B03: Is the only model that simultaneously satisfies the三位一体 requirements of hazardous area safety regulations, matching the diagnostic sensor's zero-point, and providing high-precision signals.
Documents First: Upon receiving the device, immediately verify the consistency between the product nameplate and the Explosion-Proof Certificate. The certificate is the legal and technical basis for installation; it must be archived and studied by the site engineer.
Installation Environment: Confirm that the explosion-proof rating (e.g., Ex d, Ex p) or zone classification (Zone 2) of the installation cabinet complies with the requirements of the GSI127 A2 certificate.
Safety Wiring (Top Priority):
Cables: The type of signal cable (e.g., intrinsically safe) connecting to the hazardous area must comply with certificate stipulations.
Grounding & Shielding: Strictly follow the "special conditions for safe use" in the certificate. Typically, the shield of the signal cable on the safety barrier (GSI127) side should be grounded at a single point via a dedicated grounding busbar, with the grounding resistance meeting requirements.
Entity Parameter Matching: Verify that all the output parameters (Uo, Io, Po, Lo, Co) of the diagnostic IPC707 are less than the allowed input parameters (Ui, Ii, Pi, Li, Ci) specified in the GSI127 A2-B03 certificate. This is the iron rule of intrinsic safety system design.
Power-on Commissioning:
First power-on only after confirming all safety conditions are met.
Zero-Point Verification: With the system stationary, measure the GSI127 output; it should be 8.00 VDC ±0.2V. This step verifies that the entire intelligent sensing chain (IPC707) is functioning correctly and the model is properly matched.
Diagnostic Function Test: Simulate a sensor fault to confirm the monitoring system receives the correct diagnostic alarm signal, not a vibration over-limit alarm.
GSI127 Model 244-127-000-017-A2-B03 is Meggitt's top-tier configured galvanic separation unit launched for vibration monitoring applications in high-risk explosive environments that demand extremely high signal accuracy and system diagnostic capabilities. This model represents the perfect fusion of the A2 explosion-proof certification system and the B03 high-sensitivity current transmission mode, embodying the highest safety and technical standards for achieving intelligent, precise predictive maintenance in critical hazardous areas such as oil, chemical, and natural gas industries.
In potentially explosive atmospheres, traditional safety strategies often compromise some measurement performance. The GSI127 A2-B03 completely this notion. On one hand, through the stringent explosion-proof certification implied by the A2 option (such as intrinsic safety [ia Ga] or other high-level protection types), it ensures that neither the device itself nor the associated sensor loop can become an ignition source under any fault condition, meeting the safety requirements for powering equipment in Zone 2 and even Zone 0/1 areas. On the other hand, its B03 configuration provides an industry-leading conversion sensitivity of 3.2 V/mA, dramatically "amplifying" weak sensor current signals. This ensures high signal-to-noise ratio and high-resolution voltage signals are delivered to the monitoring system even after long-distance transmission, which is crucial for detecting the faint early signs of mechanical faults.
In short, the GSI127 A2-B03 merges the mandatory requirement for safety compliance with the forward-thinking need for monitoring precision. It is not only the "operating license" ensuring a plant's safe and legal operation but also the "performance accelerator" for enhancing equipment reliability and achieving intelligent predictive maintenance upgrades. Choosing this model equips the operational status of your most critical rotating equipment in the most dangerous areas with a "nerve ending" that combines the highest safety rating with optimal monitoring performance.
Every field in the model number 244-127-000-017-A2-B03 carries specific technical and safety commitments:
GSI127: Series base code, indicating its core functions: galvanic separation, power supply, and signal conversion.
A2: Environmental Safety Grade Code. This is the mandatory safety passport for entering hazardous areas.
Legal Implication: "A2" indicates the product has been designed and manufactured according to specific international standards (e.g., ATEX, IECEx) and has obtained formal certification for use in potentially explosive atmospheres.
Key Difference: Unlike general industrial versions or basic explosion-proof versions (which may have other codes), the certification certificate corresponding to A2 clearly specifies its type of protection (e.g., Ex nA, Ex ic, or Ex ia), Equipment Protection Level, temperature class, and strict conditions for safe use. Users must obtain and adhere to this certificate before installation.
Physical Identification: According to the data, the housing of the A2 version is completely grey, distinguishing it from the A1 version which has blue sensor-side terminals.
B03: High-Performance Electrical Configuration Code. This is the technical core enabling precise and intelligent monitoring.
Operating Mode: Provides a 20 VDC constant voltage source to the sensor side, operating in current input/voltage output mode.
Ultra-High Sensitivity: Conversion sensitivity is 3.2 V/mA ±1%. This is 3.2 times that of standard models (1 V/mA). For the same current change, the output voltage change is greater, maximizing the use of the backend acquisition card's range and significantly improving signal-to-noise ratio and the ability to detect minor fault signals.
Intelligent Diagnostic Zero Point: The output zero-point voltage is 8.00 VDC ±200 mV, corresponding to a 17.50 mA quiescent current on the sensor side. This zero-point design is specifically matched to the vibro-meter® IPC707 charge amplifier with diagnostics. This diagnostic IPC707 outputs 13 mA under normal conditions, resulting in a 8 VDC output from the GSI127 B03, establishing an accurate baseline for vibration monitoring. Simultaneously, its design reserves ample dynamic range for diagnostic alarm signals (where the current may surge towards 20mA or drop).
The GSI127 A2-B03 is the hub for "high-safety" and "high-intelligence" monitoring chains, typically applied in: Vibration protection and predictive maintenance systems for critical units like gas turbines and high-speed compressors on offshore platforms, in refineries, and natural gas compressor stations.
System Architecture Breakdown:
Perception Layer (Hazardous Area Zone 1):
Device: CAxxx series high-temperature accelerometer.
Function: Senses bearing vibration, outputs charge signal.
Intelligent Conversion Layer (Hazardous Area Zone 1 or Boundary):
Signal Conversion: Converts charge signal to 4-20mA current signal.
Health Diagnostics: Monitors sensor and cable integrity in real-time. Outputs 13 mA normally; outputs a specific current value (e.g., 3.8 mA or 21 mA) as an alarm code upon fault (e.g., open or short circuit).
Device: IPC707 Charge Amplifier with Diagnostics.
Function:
Safety Interface & Performance Enhancement Layer (Safe Area or Zone 2 Control Cabinet):
Safety Isolation: Provides 4 kV isolation and acts as an intrinsically safe associated apparatus. Its certified [ia Ga] output ensures absolute safety of energy delivered to the hazardous area.
High-Precision Conversion: With 3.2 V/mA sensitivity, converts the 13 mA zero-point to 8 VDC and the 20 mA full scale to ≈17.6 VDC, maximizing the use of the acquisition card's range.
Diagnostic Compatibility: Its zero-point design and wide dynamic range can clearly and unambiguously transmit the IPC707's diagnostic codes, enabling the monitoring system to distinguish between "high vibration" and "sensor fault".
Device: GSI127 244-127-000-017-A2-B03.
Function:
Monitoring Layer (Safe Area):
Device: VM600, MMS, or other systems.
Function: Receives high-quality voltage signals for vibration analysis, alarm generation, and interpretation of diagnostic information.
Why Must the A2-B03 Combination Be Chosen?
Only B03 (Not A2): Cannot meet the regulatory mandatory certification requirements for hazardous areas; system installation would be non-compliant.
Only A2 (Not B03): For example, using A2-B01, while safety compliant, would not match the diagnostic IPC707's 13mA zero-point (causing the 8V zero-vibration signal to be misinterpreted as an offset) and would have only 1 V/mA sensitivity, significantly degrading signal quality and diagnostic compatibility.
A2-B03: Is the only model that simultaneously satisfies the三位一体 requirements of hazardous area safety regulations, matching the diagnostic sensor's zero-point, and providing high-precision signals.
Documents First: Upon receiving the device, immediately verify the consistency between the product nameplate and the Explosion-Proof Certificate. The certificate is the legal and technical basis for installation; it must be archived and studied by the site engineer.
Installation Environment: Confirm that the explosion-proof rating (e.g., Ex d, Ex p) or zone classification (Zone 2) of the installation cabinet complies with the requirements of the GSI127 A2 certificate.
Safety Wiring (Top Priority):
Cables: The type of signal cable (e.g., intrinsically safe) connecting to the hazardous area must comply with certificate stipulations.
Grounding & Shielding: Strictly follow the "special conditions for safe use" in the certificate. Typically, the shield of the signal cable on the safety barrier (GSI127) side should be grounded at a single point via a dedicated grounding busbar, with the grounding resistance meeting requirements.
Entity Parameter Matching: Verify that all the output parameters (Uo, Io, Po, Lo, Co) of the diagnostic IPC707 are less than the allowed input parameters (Ui, Ii, Pi, Li, Ci) specified in the GSI127 A2-B03 certificate. This is the iron rule of intrinsic safety system design.
Power-on Commissioning:
First power-on only after confirming all safety conditions are met.
Zero-Point Verification: With the system stationary, measure the GSI127 output; it should be 8.00 VDC ±0.2V. This step verifies that the entire intelligent sensing chain (IPC707) is functioning correctly and the model is properly matched.
Diagnostic Function Test: Simulate a sensor fault to confirm the monitoring system receives the correct diagnostic alarm signal, not a vibration over-limit alarm.
| Item | Specification | Technical Significance & Value Interpretation |
|---|---|---|
| General Power Input | ||
| Input Voltage Range | 18 - 30 VDC | Operating power for the GSI127 itself, compatible with industrial standard 24VDC systems. |
| Quiescent Current Consumption | ≤ 80 mA (@24VDC, no load) | Low power consumption design. |
| Sensor-Side Interface (B03 Mode) | ||
| Supply Output | 20 VDC ±1 VDC | Provides stable power for front-end devices like the diagnostic IPC707. |
| Output Impedance | ≤ 30 Ω | Ensures load capacity and voltage stability. |
| Signal Input Range | 0 - 20 mA | Covers the 4-20mA standard signal and diagnostic alarm over-range. |
| Input Overload Protection | 26 mA | Protects internal input circuitry from accidental surges. |
| Monitor-Side Output Interface | ||
| Output Voltage Range | 2 - 20 VDC (load ≥10 kΩ) | Wide output range, adaptable to various PLC/DCS cards. |
| Output Impedance | 20 Ω (short-circuit protected) | Strong driving capability, noise-resistant. |
| Power Supply Rejection Ratio (PSRR) | ≥60 dB (10-400 Hz) ≥30 dB (400 Hz-100 kHz) | Excellent power supply noise rejection, ensuring signal purity. |
| Zero-Point Temp. Drift | ≤ 2 mV/°C | High stability, prevents monitoring baseline drift due to ambient temperature changes. |
| Sensitivity Temp. Drift | ≤ 50 ppm/°C | Ultra-high precision, ensures long-term monitoring data consistency. |
| Output Noise | ≤ 3.5 μV RMS/√Hz | Extremely low inherent noise, ensures resolution of weak vibration signals. |
| B03 Core Conversion Characteristics | ||
| Transfer Sensitivity | 3.2 V/mA ±1% | Core advantage. Amplifies signals, improving overall system signal-to-noise ratio and resolution. |
| Output Zero-Point Voltage | 8 VDC ±200 mV | Intelligent matching point. Corresponds to 17.5mA sensor-side current, perfectly interfacing with the diagnostic IPC707's 13mA healthy zero-point. |
| Bandwidth (-0.5 dB) | DC - 20 kHz | Meets the requirements of the vast majority of mechanical vibration monitoring. |
| Typical -3 dB Frequency | 30 kHz | |
| Linearity Error | < 0.2% of F.S. | High linearity across the full scale, ensures measurement accuracy. |
| Isolation & Safety Characteristics | ||
| Channel Isolation | 4 kV RMS (sensor/monitor side) | Eliminates ground loops, blocks dangerous potential differences, protects backend systems. |
| Internal Isolation | 50 V RMS (power supply/output) | Achieves a "floating" output signal, simplifying system design. |
| Item | Specification | Notes |
|---|---|---|
| Operating Temperature | 0 to +70°C | Standard operating range inside control cabinets. |
| Storage Temperature | -40 to +85°C | Broad storage adaptability. |
| Operating/Storage Humidity | ≤90% / ≤95% RH, non-condensing | Complies with IEC 60068-2-30. |
| Vibration Resistance | 1 g peak, 5-35 Hz | Complies with IEC 60068-2-6, suitable for industrial environments. |
| Shock Resistance | 6 g peak, 11 ms half-sine | Complies with IEC 60068-2-27, robust and reliable. |
| Housing Material/Color | Polyamide (PA 66 GF 30) / Fully Grey | Signature appearance of the A2 version, flame-retardant and high-strength material. |
| Mounting Method | TH 35 DIN Rail | Quick, standard industrial mounting method. |
| Terminal Connections | Pluggable screw-clamp terminals | Facilitates wiring, maintenance, and replacement. |
| Wire Specifications | IEC: 0.2 - 2.5 mm²; UL: 26 - 12 AWG | Broad compatibility. |
| Weight | Approx. 140 grams | Lightweight and compact. |
| Item | Explanation & Requirements |
|---|---|
| Electromagnetic Compatibility (EMC) | Compliant with EN 61000-6-2 (immunity) and EN 61000-6-4 (emission) standards, ensures stable operation in complex electromagnetic environments. |
| Electrical Safety | Compliant with EN 61010-1:2010 standard, ensures operator and equipment safety. |
| Environmental Directive | RoHS (2011/65/EU) compliant, free of hazardous substances. |
| General Market Access | Holds Declarations of Conformity for CE, UKCA, EAC, etc., meeting major market requirements. |
| Explosion-Proof Certification (A2 Core) | Must be based on the accompanying valid explosion-proof certificate. • Certificate Nature: Type Examination Certificate issued by a notified body (e.g., LCIE, IECEx). • Key Content: The certificate will clearly specify: - Explosion-Proof Marking: e.g., Ex nA [ia Ga] IIC T4 Gc, where [ia Ga] indicates its use as an intrinsically safe associated apparatus for powering Zone 0/1 equipment.- Applicable Zone: e.g., "II 3 (1) G (Zone 2)", indicating this apparatus can be installed in Zone 2. - Associated Apparatus Parameters: The crucial Ui, Ii, Pi, Li, Ci values used for "entity parameter" matching with front-end sensors/conditioners. This is the mathematical foundation for ensuring system intrinsic safety. - Special Conditions for Safe Use: Specific requirements for installation, wiring, and grounding. • User Responsibility: Must obtain, understand, and strictly adhere to all clauses of the certificate before installation. |
| Item | Specification | Technical Significance & Value Interpretation |
|---|---|---|
| General Power Input | ||
| Input Voltage Range | 18 - 30 VDC | Operating power for the GSI127 itself, compatible with industrial standard 24VDC systems. |
| Quiescent Current Consumption | ≤ 80 mA (@24VDC, no load) | Low power consumption design. |
| Sensor-Side Interface (B03 Mode) | ||
| Supply Output | 20 VDC ±1 VDC | Provides stable power for front-end devices like the diagnostic IPC707. |
| Output Impedance | ≤ 30 Ω | Ensures load capacity and voltage stability. |
| Signal Input Range | 0 - 20 mA | Covers the 4-20mA standard signal and diagnostic alarm over-range. |
| Input Overload Protection | 26 mA | Protects internal input circuitry from accidental surges. |
| Monitor-Side Output Interface | ||
| Output Voltage Range | 2 - 20 VDC (load ≥10 kΩ) | Wide output range, adaptable to various PLC/DCS cards. |
| Output Impedance | 20 Ω (short-circuit protected) | Strong driving capability, noise-resistant. |
| Power Supply Rejection Ratio (PSRR) | ≥60 dB (10-400 Hz) ≥30 dB (400 Hz-100 kHz) | Excellent power supply noise rejection, ensuring signal purity. |
| Zero-Point Temp. Drift | ≤ 2 mV/°C | High stability, prevents monitoring baseline drift due to ambient temperature changes. |
| Sensitivity Temp. Drift | ≤ 50 ppm/°C | Ultra-high precision, ensures long-term monitoring data consistency. |
| Output Noise | ≤ 3.5 μV RMS/√Hz | Extremely low inherent noise, ensures resolution of weak vibration signals. |
| B03 Core Conversion Characteristics | ||
| Transfer Sensitivity | 3.2 V/mA ±1% | Core advantage. Amplifies signals, improving overall system signal-to-noise ratio and resolution. |
| Output Zero-Point Voltage | 8 VDC ±200 mV | Intelligent matching point. Corresponds to 17.5mA sensor-side current, perfectly interfacing with the diagnostic IPC707's 13mA healthy zero-point. |
| Bandwidth (-0.5 dB) | DC - 20 kHz | Meets the requirements of the vast majority of mechanical vibration monitoring. |
| Typical -3 dB Frequency | 30 kHz | |
| Linearity Error | < 0.2% of F.S. | High linearity across the full scale, ensures measurement accuracy. |
| Isolation & Safety Characteristics | ||
| Channel Isolation | 4 kV RMS (sensor/monitor side) | Eliminates ground loops, blocks dangerous potential differences, protects backend systems. |
| Internal Isolation | 50 V RMS (power supply/output) | Achieves a "floating" output signal, simplifying system design. |
| Item | Specification | Notes |
|---|---|---|
| Operating Temperature | 0 to +70°C | Standard operating range inside control cabinets. |
| Storage Temperature | -40 to +85°C | Broad storage adaptability. |
| Operating/Storage Humidity | ≤90% / ≤95% RH, non-condensing | Complies with IEC 60068-2-30. |
| Vibration Resistance | 1 g peak, 5-35 Hz | Complies with IEC 60068-2-6, suitable for industrial environments. |
| Shock Resistance | 6 g peak, 11 ms half-sine | Complies with IEC 60068-2-27, robust and reliable. |
| Housing Material/Color | Polyamide (PA 66 GF 30) / Fully Grey | Signature appearance of the A2 version, flame-retardant and high-strength material. |
| Mounting Method | TH 35 DIN Rail | Quick, standard industrial mounting method. |
| Terminal Connections | Pluggable screw-clamp terminals | Facilitates wiring, maintenance, and replacement. |
| Wire Specifications | IEC: 0.2 - 2.5 mm²; UL: 26 - 12 AWG | Broad compatibility. |
| Weight | Approx. 140 grams | Lightweight and compact. |
| Item | Explanation & Requirements |
|---|---|
| Electromagnetic Compatibility (EMC) | Compliant with EN 61000-6-2 (immunity) and EN 61000-6-4 (emission) standards, ensures stable operation in complex electromagnetic environments. |
| Electrical Safety | Compliant with EN 61010-1:2010 standard, ensures operator and equipment safety. |
| Environmental Directive | RoHS (2011/65/EU) compliant, free of hazardous substances. |
| General Market Access | Holds Declarations of Conformity for CE, UKCA, EAC, etc., meeting major market requirements. |
| Explosion-Proof Certification (A2 Core) | Must be based on the accompanying valid explosion-proof certificate. • Certificate Nature: Type Examination Certificate issued by a notified body (e.g., LCIE, IECEx). • Key Content: The certificate will clearly specify: - Explosion-Proof Marking: e.g., Ex nA [ia Ga] IIC T4 Gc, where [ia Ga] indicates its use as an intrinsically safe associated apparatus for powering Zone 0/1 equipment.- Applicable Zone: e.g., "II 3 (1) G (Zone 2)", indicating this apparatus can be installed in Zone 2. - Associated Apparatus Parameters: The crucial Ui, Ii, Pi, Li, Ci values used for "entity parameter" matching with front-end sensors/conditioners. This is the mathematical foundation for ensuring system intrinsic safety. - Special Conditions for Safe Use: Specific requirements for installation, wiring, and grounding. • User Responsibility: Must obtain, understand, and strictly adhere to all clauses of the certificate before installation. |