Schneider
A9F87240
IN STOCK
T/T
XIAMEN
| Availability: | |
|---|---|
| Quantity: | |
The A9F87240 is a 40‑ampere, double‑pole (2P) miniature circuit breaker from Schneider Electric’s Acti9 iC60H series, equipped with a C‑curve tripping characteristic (magnetic trip set at 8 × In). The C‑curve delivers an optimal balance between overload protection and tolerance of moderate inrush currents, making it an ideal solution for general‑purpose distribution applications – including lighting circuits, power sockets, small motor feeders, and control panels – in commercial, industrial, and residential settings. With both poles protected, this 2‑pole device ensures simultaneous disconnection of both lines in single‑phase AC systems or DC applications, significantly enhancing safety and isolation integrity. This MCB offers a robust ultimate breaking capacity of 30 kA at 220‑240 V AC per the industrial standard EN/IEC 60947‑2, and 10 kA at 400 V AC under the residential norm EN/IEC 60898‑1, guaranteeing reliable fault interruption across diverse and demanding environments. Certified to both standards, it provides seamless integration into mixed‑use projects. Designed with Class‑2 insulation for superior operator protection, the breaker also coordinates fully with Acti 9 RCDs and Compact NSX MCCBs, simplifying system architecture. The device features the intuitive VisiTrip fault‑finder window, which instantly identifies the tripped pole to shorten diagnostic time, and the VisiSafe green strip that delivers undeniable visual confirmation of contact opening – a critical safety check for maintenance personnel. Its quick‑make/quick‑break mechanism, independent of handle position, ensures consistent performance over 10,000 electrical and 20,000 mechanical cycles. Despite its 40 A capacity, the breaker maintains a compact 36 mm width (4 modular pitches) and clips onto DIN rails, saving valuable panel space. The terminals are engineered for heavy‑duty wiring, accepting rigid conductors up to 35 mm² and flexible up to 25 mm² with a 3.5 N·m tightening torque. The device offers IP20 protection at the terminals and IP40 when enclosed, operates reliably from -35 °C to +70 °C, and is built with halogen‑free plastics and PVC‑free materials, achieving a 54% recyclability rate and a total lifecycle carbon footprint of 41 kg CO₂ eq. – all reflecting Schneider Electric’s commitment to sustainable and safe energy distribution.
Parameter | Details |
|---|---|
General | |
Product Model | A9F87240 |
Range | Acti9 |
Product Name | Acti9 iC60 |
Device Short Name | iC60H |
Device Application | Distribution |
Poles Description | 2P |
Number of Protected Poles | 2 |
Rated Current (In) | 40 A |
Network Type | AC / DC |
Trip Unit Technology | Thermal‑magnetic |
Tripping Curve | C |
Magnetic Tripping Limit | 8 x In ± 20% |
Suitability for Isolation | Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2) |
Utilisation Category | Category A (EN/IEC 60947‑2) |
Breaking Capacity (Icu) | |
– EN/IEC 60947‑2 (AC) | 30 kA at 220…240 V AC 50/60 Hz (from product image; higher ratings at lower voltages per series) |
– EN/IEC 60898‑1 (AC) | 10,000 A at 400 V AC 50/60 Hz |
– DC ratings | Not specified in provided documents; refer to full datasheet |
Service Breaking Capacity (Ics) | Not explicitly stated; refer to standard series data (typically 50% or 100% of Icu) |
Limitation Class | Class 3 (EN/IEC 60898‑1) |
Rated Operational Voltage (Ue) | 12…60 V AC 50/60 Hz |
Rated Insulation Voltage (Ui) | 500 V AC 50/60 Hz (EN/IEC 60947‑2) |
Rated Impulse Withstand Voltage (Uimp) | 6 kV (EN/IEC 60947‑2) |
Network Frequency | 50/60 Hz |
Durability | |
Mechanical Durability | 20,000 cycles |
Electrical Durability | 10,000 cycles |
Contact Position Indicator | Yes (toggle) |
Local Signalling | Trip indicator (VisiTrip) |
Mounting & Physical | |
Mounting Mode | Clip‑on (35 mm DIN rail) |
Removable Comb Busbar | Installed; compatible top or bottom |
Connection Pitch | 18 mm between phases |
Number of Pitches | 4 (36 mm total width) |
Width | 36 mm |
Height | 85 mm |
Depth | 78.5 mm |
Net Weight | 0.25 kg |
Colour | White (RAL9003) |
Terminals & Connections | |
Connection Type | Single terminal (top or bottom), double tunnel |
Rigid Conductor (copper) | 1…35 mm² |
Flexible Conductor (copper) | 1…25 mm² |
Flexible with Ferrule (copper) | 1…25 mm² |
With Ring Terminal (Cu/Al) | Via accessory |
Multiple Conductors (with accessory) | Up to 3 x 16 mm² rigid or 3 x 10 mm² flexible |
Wire Stripping Length | 14 mm (top or bottom) |
Tightening Torque | 3.5 N·m (top or bottom) |
Earth‑leakage Protection | Separate add‑on block required |
Environmental & Protection Ratings | |
Standards Compliance | EN/IEC 60947‑2, EN/IEC 60898‑1 |
IP Degree (terminals) | IP20 (IEC 60529) |
IP in Enclosure | IP40 (Insulation class II) |
Pollution Degree | 3 (EN/IEC 60947‑2) |
Overvoltage Category | IV |
Tropicalisation | 2 (IEC 60068‑1) |
Relative Humidity | 95% at 55°C |
Operating Altitude | 0…2000 m |
Operating Temperature | -35°C … +70°C |
Storage Temperature | -40°C … +85°C |
Sustainability & Compliance | |
Halogen‑free (plastic parts) | Yes |
PVC‑free | Yes |
Silicone‑free | No |
Recyclability Potential | 54% |
EU RoHS Directive | Compliant |
REACH SVHC | Contains SVHC above threshold |
SCIP Number | 26ff71d1‑98cf‑4280‑8725‑455b9a6b2fb9 |
Packaging with recycled cardboard | Yes |
Packaging without single‑use plastic | Yes |
WEEE Label | Required for EU disposal (separate collection) |
Repair / Take‑back | No / No |
Logistics | |
Country of Origin | Not specified (typically Bulgaria for iC60 series) |
Warranty | 18 months |
Package 1 (Single unit) | 1 pc; H 7.2 cm × W 3.5 cm × L 9.5 cm; weight 239 g |
Package 2 (Box of 6) | 6 units; H 8.2 cm × W 10.0 cm × L 22.5 cm; weight 1.493 kg |
Package 3 (Pallet of 66) | 66 units; H 30 cm × W 30 cm × L 40 cm; weight 17.235 kg |
Carbon Footprint (Lifecycle) | |
Total | 41 kg CO₂ eq. |
Manufacturing (A1‑A3) | 2 kg CO₂ eq. |
Distribution (A4) | 0 kg CO₂ eq. |
Installation (A5) | 0 kg CO₂ eq. |
Use Phase (B2, B3, B4, B6) | 39 kg CO₂ eq. |
End‑of‑life (C1‑C4) | 0.7 kg CO₂ eq. |
Environmental Disclosure | Product Environmental Profile available |