Schneider
A9F95240
IN STOCK
T/T
XIAMEN
| Availability: | |
|---|---|
| Quantity: | |
The A9F95240 is a two‑pole (2P) miniature circuit breaker from Schneider Electric’s Acti9 iC60L series, featuring a K‑curve tripping characteristic (magnetic threshold at 12 × In). The K‑curve is specifically engineered for circuits that experience pronounced inrush currents – such as transformers, solenoid valves, motor starters, and capacitive loads – where standard B‑ or C‑curve breakers would be prone to nuisance tripping. With both poles protected, this 2‑pole device ensures simultaneous disconnection of both lines, providing complete isolation and enhanced safety for single‑phase AC or DC installations. Rated at 40 A, this MCB delivers a robust ultimate breaking capacity of 36 kA at 220‑240 V AC (per IEC 60947‑2) and 15 kA at 400 V AC (per IEC 60898‑1), guaranteeing reliable fault clearing even in demanding industrial environments. It is dual‑certified to both industrial and residential standards, offering flexible deployment across control panels, distribution boards, and specialised equipment protection. The breaker features the intuitive VisiTrip indicator, which instantly identifies the tripped pole for fast fault diagnosis, and the VisiSafe green strip that provides clear visual proof of contact opening – a critical safety feature for maintenance work. Its quick‑make/quick‑break mechanism, independent of handle position, ensures consistent performance over 10,000 electrical and 20,000 mechanical cycles. With a compact 36 mm width (4 modular pitches) and DIN‑rail mounting, it saves panel space, while the double‑tunnel terminals accept rigid conductors up to 35 mm² and flexible up to 25 mm² with a 3.5 N·m tightening torque. Operating reliably from -35 °C to +70 °C, this MCB is built with PVC‑free materials and achieves 54% recyclability, though it contains halogen above thresholds. Its total lifecycle carbon footprint is quantified at 41 kg CO₂ eq., reflecting Schneider Electric’s commitment to transparent environmental reporting.
Parameter | Details |
|---|---|
General | |
Product Model | A9F95240 |
Range | Acti9 |
Product Name | Acti9 iC60 |
Device Short Name | iC60L |
Device Application | Distribution |
Poles Description | 2P |
Number of Protected Poles | 2 |
Rated Current (In) | 40 A |
Network Type | AC / DC |
Trip Unit Technology | Thermal‑magnetic |
Tripping Curve | K |
Magnetic Tripping Limit | 12 x In ± 20% |
Suitability for Isolation | Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2) |
Utilisation Category | Category A (EN/IEC 60947‑2) |
Breaking Capacity (Icu) – EN/IEC 60947‑2 | |
– 12…133 V AC 50/60 Hz | 70 kA |
– 220…240 V AC 50/60 Hz | 36 kA (as per product image) |
– 380…415 V AC 50/60 Hz | < 20 kA |
– 440 V AC 50/60 Hz | 15 kA |
– < 125 V DC | < 20 kA |
Breaking Capacity (Icu) – EN/IEC 60898‑1 | |
– 400 V AC 50/60 Hz | 15,000 A |
Service Breaking Capacity (Ics) – EN/IEC 60947‑2 | |
– 12…133 V AC | 35 kA (50% x Icu) |
– 220…240 V AC | 18 kA (50% x Icu) |
– 380…415 V AC | 10 kA (50% x Icu) |
– 440 V AC | 7.5 kA (50% x Icu) |
– < 125 V DC | 20 kA (100% x Icu) |
Limitation Class | Class 3 (EN/IEC 60898‑1) |
Rated Operational Voltage (Ue) | 12…133 V AC 50/60 Hz |
Rated Insulation Voltage (Ui) | 500 V AC 50/60 Hz (EN/IEC 60947‑2) |
Rated Impulse Withstand Voltage (Uimp) | 6 kV (EN/IEC 60947‑2) |
Network Frequency | 50/60 Hz |
Durability | |
Mechanical Durability | 20,000 cycles |
Electrical Durability | 10,000 cycles |
Contact Position Indicator | Yes (toggle) |
Local Signalling | Trip indicator (VisiTrip) |
Mounting & Physical | |
Mounting Mode | Clip‑on (35 mm DIN rail) |
Removable Comb Busbar | Installed; compatible top or bottom |
Connection Pitch | 18 mm between phases |
Number of Pitches | 4 (36 mm total width) |
Width | 36 mm |
Height | 85 mm |
Depth | 78.5 mm |
Net Weight | 0.25 kg |
Colour | White (RAL9003) |
Terminals & Connections | |
Connection Type | Single terminal (top or bottom), double tunnel |
Rigid Conductor (copper) | 1…35 mm² |
Flexible Conductor (copper) | 1…25 mm² |
Flexible with Ferrule (copper) | 1…25 mm² |
With Ring Terminal (Cu/Al) | Via accessory |
Multiple Conductors (with accessory) | Up to 3 x 16 mm² rigid or 3 x 10 mm² flexible |
Wire Stripping Length | 14 mm (top or bottom) |
Tightening Torque | 3.5 N·m (top or bottom) |
Earth‑leakage Protection | Separate add‑on block (Vigi iC60) required |
Environmental & Protection Ratings | |
Standards Compliance | EN/IEC 60947‑2, EN/IEC 60898‑1 |
IP Degree (terminals) | IP20 (IEC 60529) |
IP in Enclosure | IP40 (Insulation class II) |
Pollution Degree | 3 (EN/IEC 60947‑2) |
Overvoltage Category | IV |
Tropicalisation | 2 (IEC 60068‑1) |
Relative Humidity | 95% at 55°C |
Operating Altitude | 0…2000 m |
Operating Temperature | -35°C … +70°C |
Storage Temperature | -40°C … +85°C |
Sustainability & Compliance | |
Halogen‑free status | Product contains halogen above thresholds (not halogen‑free) |
PVC‑free | Yes |
Silicone‑free | No |
Recyclability Potential | 54% |
EU RoHS Directive | Compliant |
REACH SVHC | Contains SVHC above threshold |
SCIP Number | 26F71d1‑98cf‑4280‑8725‑455b9a6b2fb9 |
Packaging with recycled cardboard | Yes |
Packaging without single‑use plastic | Yes |
WEEE Label | Required for EU disposal (separate collection) |
Repair / Take‑back | No / No |
Logistics | |
Country of Origin | France (FR) |
Warranty | 18 months |
EAN Code | 3606480084805 |
Package 1 (Single unit) | 1 pc; H 7.5 cm × W 3.5 cm × L 9.4 cm; weight 259 g |
Package 2 (Box of 6) | 6 units; H 7.8 cm × W 9.8 cm × L 22.0 cm; weight 1.614 kg |
Package 3 (Pallet of 66) | 66 units; H 30.0 cm × W 30.0 cm × L 40.0 cm; weight 18.241 kg |
Carbon Footprint (Lifecycle) | |
Total | 41 kg CO₂ eq. |
Manufacturing (A1‑A3) | 2 kg CO₂ eq. |
Distribution (A4) | 0 kg CO₂ eq. |
Installation (A5) | 0 kg CO₂ eq. |
Use Phase (B2, B3, B4, B6) | 39 kg CO₂ eq. |
End‑of‑life (C1‑C4) | 0.7 kg CO₂ eq. |
Environmental Disclosure | Product Environmental Profile available |