The MPC4 200-510-076-115 is a core component—the Standard version Machinery Protection Card—within the Meggitt Sensing Systems Vibro-Meter VM600 series Machinery Protection System. The product code precisely indicates its attributes: firmware version 076 and hardware version 115. This model represents the next generation in the ongoing evolution of the VM600 system, with the hardware version increment (the "H" value increased from 4 to 5 compared to version 114) signifying optimizations and improvements in internal circuit design, component selection, or manufacturing processes aimed at enhancing reliability and long-term stability. It inherits all the key advantages of later-generation models following the 2017 improvements: full compliance with the RoHS environmental directive and an optimized circuit design delivering a low output impedance of 50 Ω, ensuring excellent drive capability at the signal output and compatibility with test equipment.


As a benchmark product in the field of industrial rotating machinery protection, the MPC4 card acts as a "guardian angel" for equipment safety. Leveraging its powerful real-time processing capabilities, it performs continuous acquisition, precise analysis, and intelligent judgment of signals from various sensors (e.g., vibration probes, displacement sensors, dynamic pressure transmitters, tachometer probes). The system can simultaneously and independently monitor 4 dynamic signal channels and 2 speed/keyphasor signal channels, utilizing advanced digital signal processing algorithms to complete the entire process from raw signal to protection decision within milliseconds. When monitored parameters deviate from the normal range or reach preset safety red lines, it immediately activates a multi-level alarm system and executes predetermined protective actions via relay outputs, effectively preventing equipment damage, ensuring production safety, and improving operational efficiency.


This card must be used in conjunction with an IOC4T Input/Output Card, forming a functionally complete monitoring channel unit. Multiple such units can be integrated into a VM600 Standard Rack to build a modular, scalable, centralized machinery protection system that meets international standards such as API 670, providing a highly reliable safety barrier for a plant's critical rotating equipment.

2. Core Features and Advantages

  • High-Performance Multi-Channel Parallel Processing Architecture: Equipped with a powerful Digital Signal Processor, enabling true parallel processing of 4 dynamic measurement channels and 2 speed channels. Parameters for each channel (signal type, range, filtering characteristics, alarm values, etc.) can be independently and flexibly configured via software, meeting diverse application needs from simple vibration monitoring to complex shaft train analysis.

  • Professional-Grade Signal Processing and Analysis Toolkit:

    • Programmable Filter Bank: Provides broadband filters such as high-pass, low-pass, and band-pass, as well as Narrowband (Order) Tracking filters for precise fault diagnosis (employing constant-Q technology, Q=28). Narrowband tracking effectively suppresses non-synchronous vibrations, accurately extracting running speed and its harmonic components, making it a powerful tool for diagnosing faults like unbalance, misalignment, and blade-pass frequency.

    • Industry-Standard Rectification Algorithms: Supports True RMS, Mean, True Peak, and True Peak-to-Peak rectification. True peak and peak-to-peak measurements are crucial for capturing transient events like impacts and rubbing, meeting the most stringent machinery protection standards.

    • Simultaneous Order Amplitude and Phase Measurement: During speed changes, it can lock onto and extract vibration components of specific orders (e.g., 1X, 2X), simultaneously providing the amplitude and phase angle relative to the keyphasor for that component, offering direct data for on-site dynamic balancing correction and fault source localization.

  • Intelligent, Configurable Protection Logic Engine:

    • Four-Level Alarm Threshold Management: Each dynamic channel can be independently configured with Alert+ (High Alert), Alert- (Low Alert), Danger+ (High Danger), and Danger- (Low Danger) thresholds, each with independent delay, hysteresis, and latching functions to effectively prevent false alarms caused by signal fluctuations and enhance system reliability.

    • Adaptive Monitoring Strategy: Allows Alert and Danger limits to be automatically adjusted based on the machine's operating speed (or other process parameters via voltage-to-frequency conversion). This feature is particularly important during unit start-up and shutdown, allowing automatic adaptation to critical speed regions and avoiding unnecessary protective actions.

    • External Control Interfaces: Provides Direct Trip Multiply and Danger Bypass functions, enabling rapid adjustment of protection thresholds or temporary masking of danger outputs via external discrete signals, offering great flexibility for operation and maintenance.

    • Powerful Logic Combination Functions: Features a built-in programmable logic unit, providing up to 8 Basic Logic blocks and 4 Advanced Logic blocks. Users can perform "AND," "OR," "M out of N," and other logical operations on signals such as alarms, dangers, sensor OK status, and external digital inputs from any channel to construct complex redundant protection, voting shutdown, or process interlock logic, meeting high-safety application requirements.

  • Integrated Power Supply and Health Diagnostics System:

    • The card integrates isolated DC power supplies such as +27.2V, -27.2V, +15V, which can directly power sensors like IEPE accelerometers, eddy current probes, and magnetic speed sensors, simplifying external power configuration and wiring.

    • The unique "OK System" continuously performs online diagnostics on the health of each sensor signal chain, reliably detecting faults such as sensor open circuit, short circuit, cable damage, and power supply abnormalities. It promptly reports these via independent channel OK alarms and a global card OK alarm, ensuring the integrity of the monitoring system itself and achieving "self-monitoring."

  • Engineering and Maintenance-Friendly Design:

    • Convenient Front-Panel Diagnostic Ports: Equipped with 6 standard BNC connectors (4 dynamic + 2 speed) for direct connection to portable devices like oscilloscopes and spectrum analyzers, facilitating online signal verification, in-depth fault analysis, and system performance testing without interrupting the protection function.

    • Intuitive Multi-Level Status Visualization: The front panel features a complete set of color LED indicators. A global DIAG/STATUS light reflects the overall operating status of the card in real time, while six independent channel status lights clearly display the sensor validity, alarm/danger status, and channel inhibit status for each channel, providing clear on-site information at a glance.

    • Hot-Swappable Operation: Allows card installation or replacement in a powered-on VM600 system, greatly improving system availability, supporting online maintenance and rapid fault recovery, and reducing unplanned downtime.

  • Rich Interfaces and Powerful System Integration Capabilities:

    • Analog Outputs: Through the paired IOC4T card, it provides 4 isolated 0-10V or 4-20mA analog outputs, continuously sending key processed parameters like overall vibration and shaft position to the plant DCS, PLC, or asset management system for process monitoring, trend analysis, and historical data recording.

    • Relay Control Outputs: Generated alarm and danger signals can directly drive the 4 relays on the IOC4T card or, via the rack's backplane Open Collector Bus, drive expansion relay cards (e.g., RLC16 or IRC4), enabling flexible and reliable shutdown, alarm, and pre-alarm outputs.

    • Flexible Configuration and Communication Paths: Supports local configuration and debugging via the front-panel RS-232 serial port, while also supporting remote networked configuration, real-time data monitoring, and communication via the VME bus (requires installation of a CPUx series controller card in the rack), easily integrating into a plant-wide digital monitoring network.

  • Strict Adherence to International Safety and Quality Standards: The design and manufacturing of this "Standard" version MPC4 card comply with international standards IEC 61508 (Functional Safety) and ISO 13849 (Safety of Machinery), making it suitable for applications requiring up to SIL 1 / PL c Safety Integrity Levels. It has obtained relevant certifications, providing users' critical assets with verifiable safety assurance.

3. Typical Application Areas

The MPC4 card pair is an indispensable core safety component in the energy, heavy industry, and critical infrastructure sectors, widely used in:

  • Power Industry: Various steam turbines, gas turbines, combined cycle units, hydro-generator sets, major auxiliary equipment (e.g., feedwater pumps, fans).

  • Oil, Gas & Petrochemicals: Long-distance pipeline compressors, offshore platform turbo machinery, refinery large compressor sets, high-speed reciprocating compressors.

  • Basic Industries: Large industrial air compressors, metallurgical blast furnace blowers, chemical process compressors, turbo-expanders.

  • Marine & Offshore Engineering: Ship main propulsion turbines, shipboard prime movers for power generation, reduction gearboxes, and propulsion shafting.

Its core mission is to provide independent, continuous, and highly reliable machinery protection while also serving as a solid data foundation for implementing condition early warning and predictive maintenance.

4. Operating Principle and Workflow

The MPC4 card operates according to an efficient, deterministic real-time signal processing chain:

  1. Signal Acquisition & Preprocessing: Analog signals from field sensors are received via the IOC4T card. Current signals are converted to voltage signals via a precision sampling resistor. All signals undergo programmable gain/attenuation adjustment and are then split into two processing branches: Alternating Current (AC, representing dynamic quantities like vibration) and Direct Current (DC, representing static quantities like gap, position).

  2. Digitization & Core Computation:

    • AC Path: The signal passes through anti-aliasing filtering and is digitized by a high-speed Analog-to-Digital Converter. The DSP, based on user configuration, performs required digital integration or differentiation, applies optional broadband or narrowband digital filters, and finally performs the specified rectification calculation (e.g., RMS, Peak).

    • DC Path: The signal undergoes low-pass filtering and sampling, after which the static engineering value is calculated by the DSP.

  3. Monitoring Comparison & Status Decision: The processed AC dynamic value (e.g., overall vibration) and DC static value are compared in real-time against user-preset multi-level Alert and Danger limits. Simultaneously, the DC component of the signal is continuously monitored by the "OK System" to verify sensor chain integrity. All comparison results are updated in real-time.

  4. Logic Synthesis & Final Execution: The raw alarm, danger, and OK statuses from individual channels are fed into programmable logic function blocks, where they are synthetically judged according to preset complex strategies to generate final protection commands. Based on these commands:

    • Relay contacts on the IOC4T card or expansion relay cards are controlled.

    • Processed standard engineering values are output as analog signals via Digital-to-Analog Converters.

    • All front-panel LED indicators are driven in real-time, providing clear local status display.

5. Status Indicator Description

The MPC4 card's front-panel LEDs serve as an important human-machine interface:

  • DIAG/STATUS (Card Diagnostic Light): Multi-color indicator. Green Continuous = Normal operation; Yellow Continuous = Trip Multiply (TM) function active; Red Continuous = Danger Bypass (DB) function active; Green Blinking = Configuring or channel has input signal error; Yellow or Red Blinking = Indicates configuration error or internal card hardware/firmware fault (red blinking indicates the highest priority fault).

  • Channel Status Indicators (RAW OUT 1-4, TACHO OUT 1-2): One multi-color light per channel.

    • Measurement Channels: Green Continuous = Channel configured normally and signal valid; Green Blinking = Sensor OK system detected a fault; Yellow Continuous/Blinking = Alert status active; Red Continuous/Blinking = Danger status active; Slow Green Blink (~1Hz) = Channel is "Inhibited."

    • Speed Channels: Green Continuous = Normal; Green Blinking = Sensor OK fault or invalid input signal; Yellow Continuous = Alert status active; Slow Green Blink = Channel is "Inhibited."

6. System Integration and Selection Guidance

As the currently promoted "Standard" version model, the typical system configuration for the MPC4 200-510-076-115 is as follows:

  1. Core Unit: One MPC4 Card must be paired with one corresponding version IOC4T Card (it is recommended to order PNR 200-560-000-115 or a compatible version).

  2. System Platform: The card pair must be installed in the designated slots of a VM600 Series Standard Rack (e.g., ABE04x).

  3. Function Expansion:

    • If more relay output points are needed, add RLC16 (16 relays) or IRC4 (8 intelligent relays) expansion cards.

    • To connect to the plant network and for centralized configuration management, a CPUx Series Communication and Controller Card must be installed in the rack.

  4. Software Tool: Use the official Meggitt VM600 MPSx series engineering software to perform comprehensive parameter configuration, online monitoring, and data analysis for the card pair via serial port or network.

Version Identification: The Standard version MPC4 card's front-panel lower handle label has white "MPC 4" text on a blue background. In the VM600 MPSx configuration software (v2.6.x and above), this card appears as the "MPC4" type in the device list.


Important Note: The MPC4 200-510-076-115 is a recommended model with full functionality, RoHS compliance, and a 50Ω output impedance, suitable for the vast majority of new and upgrade machinery protection projects. For special applications with strict functional safety (SIL) certification requirements that plan to deploy both safety protection cards and advanced condition monitoring cards (e.g., XMx16) within the same rack, the specifically designed and certified MPC4SIL (Safety version) card should be selected. Before final selection, always refer to the latest official technical documentation and consult the Meggitt technical support team for accurate guidance.


Specification Category Parameter Details Description & Notes
Dynamic Signal Inputs
Number of Channels: 4, Fully Isolated & Independently Programmable
Signal Type Voltage or Current Software selectable, supports AC+DC coupled signal input.
DC Voltage Range 0 to +20 V or 0 to -20 V
AC Voltage Range ±10 V (peak, maximum)
Common Mode Voltage Range -50 V to +50 V
Common Mode Rejection Ratio ≥ 60 dB @ 50 Hz
Input Impedance 200 kΩ (for voltage input)
DC Current Range 0 to 25 mA
AC Current Range ±8 mA (maximum)
Analog Bandwidth (-3dB) DC to 60 kHz Applicable in Raw Bus sharing mode.
AC Frequency Response (No Integration) 0.1 Hz to 10 kHz For velocity or displacement sensors.
AC Frequency Response (With Integration) 2.5 Hz to 10 kHz For integrating acceleration from accelerometers to velocity.
Current Measuring Resistor 324.5 Ω For current-to-voltage signal conversion.
Speed/Keyphasor Inputs*
Number of Channels: 2
Triggering Method Rising / Falling Edge Threshold Trigger Software configurable.
Dynamic Trigger Thresholds Rising = (2/3) × Peak-to-Peak, Falling = (1/3) × Peak-to-Peak Calculated automatically based on input signal amplitude.
Tachometer Range Raw Input: 0.016 Hz to 50 kHz
Displayed Output: 0.016 Hz to 1092 Hz (1 to 65,535 RPM)
Supports multi-pulse gear tooth input.
Input Voltage Range 0.3 Hz - 10 kHz: 0.4 - 500 Vpp
10 kHz - 50 kHz: 2.0 - 500 Vpp
Compatible with eddy current, magnetic, photoelectric, and TTL signal sources.
Min. Reliable Trigger Voltage Square Wave (10 Hz-10 kHz): 0.8 Vpp
Sine Wave (1 Hz-10 Hz): 2.0 Vpp

Buffered Signal Outputs

Output Content Sensor "Raw" signals (Analog/Digital) For external advanced diagnostics and recording.
Output Interface MPC4 Front-Panel BNC, IOC4T Rear-Panel Screw Terminals Dual access points for convenient connection.
Output Impedance 50 Ω Standard configuration for model 076-115, providing excellent signal fidelity and drive capability.
Dynamic Channel Transfer Ratio Voltage Input: 1 V/V
Current Input: 0.3245 V/mA
Output is a buffered mirror of the input signal.
Speed Channel Output 0 to 5 V, TTL-compatible level Front-panel BNC output.
Analog Outputs (IOC4T)

Output Channels 4 channels (DC OUT 1 to 4) Correspond to processed engineering values (e.g., vibration severity, position).
Output Type & Range 4 to 20 mA or 0 to 10 V Can be selected independently per channel via jumpers on the IOC4T card.
Over-Range Linearity Supports linear output beyond the nominal range Current: ~0-23.1 mA; Voltage: ~-2.5-11.9 V.
Signal Processing Functions

Broadband Processing High-pass, Low-pass, Band-pass filters selectable Attenuation slope: 6 to 60 dB/octave (programmable).
Narrowband Tracking Processing* Constant Q filter (Q = 28) Frequency Range: 0.15 Hz to 10 kHz

Extractable Orders: 1/3X, 1/2X, 1X, 2X, 3X, 4X

Phase Error: ≤ ±6° (max), ≤ ±1° (typical, 1X order)
Relative Shaft Vibration Proc. Vibration Frequency: 0.1 Hz - 10 kHz; Gap/Position: DC - 1 Hz Features initial electrical gap compensation.
Amplitude Measurement Accuracy ±1% of full scale (typical, broadband processing)
Linearity Error ≤ ±1%
Alarm & Logic Control

Measurement Channel Setpoints Alert+ (High), Alert- (Low), Danger+ (High), Danger- (Low) Each point independently programmable.
Speed Channel Setpoints Alert+ (High), Alert- (Low)
Adjustable Parameters Limit, Delay Time, Hysteresis Value, Latching Mode
Adaptive Monitoring Supported Automatically adjusts alarm limits based on speed or other external parameters.
Direct Trip Multiply (TM)* Supported External TM signal controls limit multiplier coefficient (0.1-5.0) switching.
Danger Bypass (DB)* Supported External DB signal temporarily inhibits danger relay action.
Channel Inhibit* Supported Software-controlled temporary masking of a specified channel's protection output.
Logic Combination Functions 8 Basic Logic + 4 Advanced Logic Supports complex logic like AND, OR, "M out of N" voting.
OK System Diagnostics

Monitoring Principle Monitors sensor chain via DC signal component
Diagnostic Thresholds User-configurable Upper and Lower Limits
Voltage Input OK Range ±20 V DC
Current Input OK Range 0 to 23 mA
Fault Confirmation Time 250 ms (firmware set) Prevents false alarms from noise or transient interference.
System Response Time < 100 ms Time from fault confirmation to alarm output generation.
Electrical Characteristics

Card Operating Power +5 VDC, ±12 VDC Supplied by the VM600 rack backplane.
Typical Power Consumption +5V: 12.5W (typical) + ~1W per sensor
±12V: Max 2.5W

Sensor Power Supply Output +27.2 V (±5%), -27.2 V (±5%), +15.0 V (±5%) Max output current per channel: 25 mA.
Overcurrent Protection +5 V line: 11.0 A
Environmental Specifications

Operating Temperature -25°C to +65°C
Storage Temperature -40°C to +85°C
Operating Humidity 0 to 90% Relative Humidity, non-condensing
Communications & Configuration

Configuration Interface RS-232 Serial Port (MPC4 front panel)
VME Bus (via CPUx card in rack)
076-115 supports dual configuration modes.
MPC4 ↔ IOC4T Internal Bus Dedicated high-speed parallel bus similar to Industry Pack (IP)
Host Communication Supports Ethernet and mainstream fieldbus protocols (e.g., Modbus TCP, PROFIBUS) via CPUx card
Physical Attributes

Dimensions (H x W x D) 6U x 20 mm x 187 mm Compliant with VME Eurocard standard.
Weight Approx. 0.40 kg
Certifications & Compliance

EMC IEC/EN 61000-6-2, IEC/EN 61000-6-4
Electrical Safety IEC/EN 61010-1
Functional Safety Compliant with IEC 61508 (SIL 1) & ISO 13849-1 (PL c) "Standard" version product certification.
Environmental RoHS Compliant Core compliance for version 076-115.
Other Certifications CE Marking, EAC (Eurasian Economic Union) Conformity Marking
Previous: 