nyban1
You are here: Home » Systems » Turbine Supervisory Instrumentation » VM600 Machinery Protection Systems » CPUM 200-595-100-014 CPU Card
Leave Us A Message

loading

CPUM 200-595-100-014 CPU Card

  • VM

  • CPUM 200-595-100-014

  • $6900

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

CPUM 200-595-100-014 is a rack control and communication interface card with a specific firmware configuration within the Meggitt Vibro-Meter VM600 series rack-mounted machinery protection and condition monitoring system. This model number identifies a specific configuration combination of the CPUm/IOCN card pair, where the firmware version identifier for the CPUM card is 100 and the hardware revision is 014. Within the VM600 product sequence, this model represents a special configuration state: its firmware version "100" is described in the attachment as a specific "Standard Configuration" code (corresponding to 610-100-000), typically representing the default feature set uploaded to the card when no other special configuration is specified; while the hardware revision "014" indicates a relatively early hardware iteration. Therefore, CPUM 100-014 can be understood as a rack controller and communication gateway running on an early hardware platform, equipped with the standard basic functions of the VM600 system.


This product serves as the core control and communication hub for the VM600 rack-mounted monitoring system. It integrates standard rack management, data concentration, local display, and basic fieldbus communication functions, aiming to provide a reliable and economical control center for small to medium-sized monitoring systems using protection cards like MPC4 and AMC8. Its "100" Standard Configuration firmware ensures the card possesses out-of-the-box basic functions, including communication with external systems via the Modbus protocol, managing rack configuration, and providing a front-panel human-machine interface. The hardware revision 014 signifies that it is based on the hardware design from the early development phase of the VM600 product, and there may be differences in component selection, manufacturing details, and certain performance indicators compared to later hardware revisions (e.g., 114, 122, 332).


The CPUM 200-595-100-014 must be used paired with a compatible IOCN Input/Output card of the matching hardware revision and installed in a VM600 ABE04x standard system rack (6U). This model is primarily intended for the following scenarios: maintenance and spare part replacement for existing early VM600 systems, or for application projects with clearly defined functional needs limited to the standard configuration and high sensitivity to cost. It represents a typical configuration from the popularization phase of the VM600 platform, its value lying in providing proven basic functionality and high cost-effectiveness.

2. Core Features and Advantages

  • Standardized Basic Functions and High Cost-Effectiveness:

    • Ready-to-Use Standard Configuration: Equipped with "100" Standard Configuration firmware, providing the most core and commonly used set of functions for a VM600 CPU card. Users can put it into service without complex specific configuration, reducing engineering startup complexity and time costs.

    • Proven Early Hardware Platform: The hardware revision 014 utilizes a hardware design widely validated in the early days of the VM600 product. While it may not possess some enhanced features of later versions, it delivers stable performance in standard industrial environments and, as a mature platform, often offers better acquisition cost.

    • Basic Hot-Swap and Rack Management: Supports basic hot-swap operations for monitoring card pairs, with firmware enabling card identification. As the rack controller, it facilitates unified parameter configuration and management of protection cards via the VM600 MPSx software.

    • Practical Local Status Display: The front panel features an LCD display showing CPUM's own basic information (e.g., IP address) and key measurement data and alarm statuses for protection cards in each slot, meeting basic on-site monitoring needs.

  • Basic Industrial Communication Connectivity:

    • Core Modbus Protocol Support: As the core of the standard configuration, it reliably supports both Modbus RTU (serial) and Modbus TCP (Ethernet) communication protocols, capable of integrating VM600 system data into the vast majority of plant control systems (DCS/PLC) using Modbus.

    • Clarification on PROFINET Support: According to explicit information in the attachment, standard PROFINET support began with later CPUM cards running firmware version 081 or higher. Therefore, the Standard Configuration firmware identified as "100" (whose base version likely predates 081) does not include native, standardized support for the PROFINET protocol. If PROFINET is required, a specific model with firmware version 081 or above must be selected.

    • Basic Communication Interfaces: Provides standard dual Ethernet ports (Primary/Secondary) and serial communication interfaces (RS-232/RS-485), meeting typical network connection needs.

  • Essential System Management and Security Functions:

    • Centralized Configuration Management: Achieves centralized upload, download, and monitoring of configurations for all rack protection cards via VM600 MPSx software (must be compatible with the corresponding firmware version).

    • Basic Security Mechanism: Supports the basic implementation of VM600 MPS Rack (CPUM) Security functionality, allowing access restrictions to be set via front-panel operations and software, providing basic protection for core protection logic.

    • System Event Logging: Possesses the capability to log system operational events, providing basic data support for troubleshooting and operational history tracing.

  • Focus on Compatibility and Cost-Effectiveness:

    • Broad Rack Compatibility: Compatible with VM600 ABE04x system racks, ensuring integration into standard VM600 systems.

    • Clear Functional Boundaries: As a Standard Configuration product, its functional scope is clear and fixed, helping users perform accurate technical selection and cost assessment at the project's outset, avoiding payment for unused features.

    • Suited for Standard Environments: Its hardware design targets common industrial control cabinet environments, meeting standard requirements for temperature, humidity, vibration, etc., suitable for most in-plant installation scenarios.

3. Typical Application Areas

The CPUM 200-595-100-014, with its standardized functions and economic positioning, is suitable for the following specific areas:

  • Maintenance and Spare Parts Supply for Early VM600 Systems: Serves as a direct, compatibility-guaranteed maintenance spare part or replacement unit for production lines or equipment still utilizing VM600 systems with hardware revision 014 or compatible early firmware standard configurations. This is its primary application scenario.

  • Monitoring Projects with Simple Functional Requirements: For new, small to medium-sized machinery protection or condition monitoring projects with a moderate number of monitoring points, where the higher-level system only requires data acquisition via the Modbus protocol (TCP or RTU). This standard configuration can be considered if the budget is limited and there are no special requirements for the latest features.

  • Monitoring of Non-Critical Equipment: Applicable for monitoring systems on auxiliary equipment in non-continuous production processes or where reliability requirements are not extremely stringent.

  • Education and Training Systems: Due to its standard functions, typical configuration, and relatively low cost, it can be used to build teaching demonstration or operational training platforms for industrial monitoring systems.

4. Operating Principle and System Integration

As the rack control core with Standard Configuration, the CPUM 200-595-100-014 operates according to the basic architecture of the VM600 system:

  1. VME Bus Communication: Acts as the master device, communicating via the rack backplane VME bus with various protection cards (MPC4, AMC8) to collect data and status.

  2. Data Concentration and Standard Mapping: The CPU centrally processes data and maps internal variables to Modbus addresses based on predefined, generic mapping relationships within the "100" Standard Configuration.

  3. Modbus Gateway Service: Acts as a Modbus TCP Server and/or Modbus RTU Slave, responding to requests from external masters, providing measurement values, alarm statuses, etc.

  4. Basic System Services: Executes local display updates, basic event logging, and fundamental configuration and security management via the front panel and software.


Important Integration Considerations:

  1. Protocol Compatibility Confirmation: Confirm the project only requires Modbus integration and definitively does not need PROFINET. This is a prerequisite for selecting this model.

  2. Software Version Matching: Must use a VM600 MPSx software version capable of recognizing and compatible with this specific hardware revision (014) and the "100" Standard Configuration. Using too new or incompatible software may cause communication or configuration failures.

  3. Hardware Compatibility and Mixing: Avoid mixing with later-produced monitoring cards or rack accessories with significantly different hardware revisions, as untested compatibility issues may arise. It is recommended to maintain the entire system with hardware of similar generations.

  4. Environmental and Regulatory Compliance: Ensure to confirm the environmental status (e.g., RoHS) of hardware revision 014, guaranteeing it complies with the environmental regulations of the project location or end-user to avoid subsequent risks.

5. Version Positioning and Selection Advice

  • Positioning within the VM600 Product Family:
    The CPUM 100-014 is the "Basic Standard Configuration Model" within the VM600 series. It represents a standardized, economical solution from a specific period in the product's evolution (hardware revision 014, Standard Configuration software). Its value lies in its clear functionality and cost optimization, but its technical characteristics are fixed at the level of its release.

  • Comparison with Other Versions and Selection Decision:

    Consideration Dimension Choosing CPUM 100-014 Choosing a Newer Version (e.g., CPUM 072-122, 082-332)
    Primary Drivers 1. Spare part replacement for an existing early system (using 014 hardware/100 configuration).
    2. New projects with extreme cost sensitivity and functional requirements perfectly matching this Standard Configuration.
    1. The mainstream choice for new construction projects.
    2. Need for PROFINET support.
    3. Need for newer firmware features (e.g., enhanced diagnostics, optimized performance).
    4. Need for higher hardware reliability (e.g., 122, 332 platform) or latest environmental compliance.
    Advantages - Lowest compatibility risk as a spare part for compatible legacy systems.
    - Potentially lower acquisition cost.
    - Richer or more advanced functionality.
    - Long-term technical support and product lifecycle are more favorable.
    - Better hardware reliability and environmental compliance.
    Disadvantages/Risks - Limited functionality, cannot access enhanced features of later versions.
    - May not comply with latest environmental regulations (e.g., RoHS).
    - Long-term supply and technical support may be limited.
    - Potentially higher initial investment.
    - For pure spare part replacement, there may be minor compatibility verification work.
  • Final Recommendations:

    • It is strongly recommended to use the CPUM 200-595-100-014 only for direct spare part replacement and maintenance of already deployed systems, to maintain system consistency and stability.

    • For any new construction project, system upgrade, or retrofit project, even if the functional requirements seem simple, it is strongly advised NOT to select this legacy model. Current models with newer hardware revisions (e.g., 122 and above), explicit firmware versions (e.g., 072, 081, 082), and full support should be selected to ensure the project's long-term reliability, functional scalability, and compliance security.


Specification Category Parameter Details Explanation and Notes (for 100-014 version)
Product Model & Version

Model CPUM 200-595-100-014 Key Identifiers: "100" is the Standard Configuration firmware code, "014" is the early hardware revision.
Card Pair Composition CPUM (CPU Card) + IOCN (I/O Card) Must be used as a pair; the IOCN card should be of the corresponding early hardware revision.
Configuration/Firmware Identifier 100 "Standard Configuration" identifier. According to the attachment, this code (corresponding to 610-100-000) represents the standard default functional configuration set uploaded to the CPUM card, containing the factory basic functions. It does not refer to a specific firmware serial number (e.g., 072, 081).
Hardware Revision 014 Early Hardware Revision. Indicates its hardware design is based on the technical scheme from the initial phase of the VM600 product, and may differ from subsequent versions (e.g., hardware post-100 series) in components, manufacturing, and some performance parameters.
Rack Compatibility

Compatible Rack VM600 ABE04x System Rack (6U) Compatible.
Occupied Slots CPUM: Slot 0 and 1 (front, double-width)
IOCN: Slot 0 (rear, single-width)

CPU Module (Based on HW 014)

Module Type PFM-5411 or equivalent module from that period
Processor AMD Geode™ LX800 or contemporary processor
Processor Speed 500 MHz
Memory 256 MB DRAM (early specification)
Operating System QNX
Communication Interfaces - Ethernet

Number of Interfaces 2 (Primary, Secondary)
Network Standard 10/100BASE-TX
Data Transfer Rate Up to 100 Mbps
Supported Protocols • Primary Interface: Meggitt proprietary protocol (for VM600 MPSx software), Modbus TCP
• Secondary Interface: Modbus TCP
Core Communication Capability: Standard configuration focuses on Modbus TCP.
Communication Interfaces - Serial

Number of Interfaces 2 (Primary, Secondary)
Network Interface • Primary: RS-232
• Secondary: RS-485 (isolated)

Data Transfer Rate Up to 115.2 kbps
Supported Protocols • Primary: Meggitt proprietary protocol (for MPSx software)
• Secondary: Modbus RTU

Fieldbus Interface Overview
Typical support for the "100" Standard Configuration
Standard Support Modbus RTU, Modbus TCP Meets basic data integration needs.
PROFINET Support Not Supported. The attachment states standard PROFINET support requires firmware version 081 or above. The Standard Configuration "100" does not fall into this category. Key Limitation.
Front Panel Display & Control

Display LCD Display Displays information supported by the standard configuration.
Control Buttons SLOT+/-, OUT+/-, ALARM RESET
Status Indicators (LEDs)

DIAG, OK, A, D Basic status indication functions.
System Functions
Feature set based on the Standard Configuration
Configuration Management Via VM600 MPSx software (compatible version).
Event Logging Supports basic system event logging.
Security Function Supports basic implementation of VM600 MPS Rack Security.
Electrical Characteristics

Power Input +5 VDC (from rack)
Power Consumption Typical consumption level per early hardware design.
Environmental Specifications
Standard environmental ratings for early hardware revision
Operating Temperature -20°C to +65°C (typical)
Storage Temperature -25°C to +80°C
Humidity 0-90% RH, non-condensing
Compliance & Certification (Historical Status)
Certifications for hardware revision 014 likely based on early standards
Environmental (RoHS) Most likely does not comply with current RoHS directives, being a product from before or during the transition phase of the directive's enactment. Must verify before procurement; involves environmental compliance risk.
Safety & EMC Should conform to the applicable safety and EMC standards at the time of product manufacture (e.g., CE directives of that time).
Physical Attributes

Dimensions CPUM: 6U x 40mm x 187mm; IOCN: 6U x 20mm x 125mm
Weight Approx. CPUM: 0.40kg; IOCN: 0.25kg
Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.