nyban1
You are here: Home » Systems » Turbine Supervisory Instrumentation » VM600 Machinery Protection Systems » MPC4 200-510-076-114 Machinery Protection Card
Leave Us A Message

loading

MPC4 200-510-076-114 Machinery Protection Card

  • VM

  • MPC4 200-510-076-114

  • $5800

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The MPC4 200-510-076-114 is the core processing unit—the Standard version Machinery Protection Card—within the Meggitt Vibro-Meter brand's VM600 series Machinery Protection System. This model number identifies its firmware version as 076 and hardware version as 114. This version belongs to the later generation of VM600 products following significant improvements implemented in 2017. Its hallmark upgrades include full compliance with the RoHS environmental directive and a redesign of key circuitry, which optimized the front-panel buffered dynamic signal output impedance from 2000Ω in earlier models to 50Ω. This significantly enhances signal output drive capability and compatibility with standard measurement instruments, reduces signal reflection and attenuation, and facilitates more precise online diagnostics.


As an online protection core designed for critical rotating machinery, the MPC4 card assumes the responsibility of real-time, continuous safety monitoring. It simultaneously processes up to 4 dynamic signal channels (e.g., vibration, displacement, dynamic pressure) and 2 speed/keyphasor signal channels, utilizing advanced Digital Signal Processing (DSP) technology to monitor and assess machine health at a millisecond level. Upon detecting an abnormal trend or a parameter exceeding a safety threshold, it can immediately initiate multi-level alarms (Alert, Danger) and drive relays to execute protective actions (e.g., audible/visual alarms, interlock shutdown), effectively preventing catastrophic failures, ensuring continuous production, extending equipment life, and optimizing maintenance strategies.


This card must be paired with a corresponding IOC4T Input/Output Card to form a complete "sensing-processing-execution" unit. Multiple such card pairs can be integrated into a VM600 Standard Rack to build a modular, scalable, and highly reliable plant-wide machinery protection network, meeting the stringent requirements of international standards like API 670 for the independence and reliability of a Machinery Protection System (MPS).

2. Core Features and Advantages

  • Exceptional Multi-Channel Independent Processing: Equipped with a high-performance DSP, it independently and simultaneously processes 4 universal dynamic channels and 2 dedicated speed channels. Channel type (acceleration/velocity/displacement), range, filtering, alarm values, etc., for each channel are independently configurable via software, providing unparalleled flexibility to accommodate various sensors and monitoring needs.

  • Comprehensive Intelligent Signal Processing Suite:

    • Programmable Filter Network: Offers broadband filtering from high-pass, low-pass to band-pass, as well as Narrowband (Order) Tracking filtering (constant-Q technology) for precise fault feature extraction. Narrowband tracking effectively isolates background noise and focuses on running speed and its harmonics, making it extremely effective for diagnosing typical faults like unbalance, misalignment, and looseness.

    • Multiple Industry-Standard Rectification Methods: Supports True RMS, Mean, True Peak, and True Peak-to-Peak rectification. True peak and true peak-to-peak measurements are critical for monitoring reciprocating machinery or impact-type faults, complying with the strictest machinery protection standards.

    • Simultaneous Order Amplitude and Phase Analysis: During speed changes, it can lock onto a specific order (e.g., 1X, 2X), simultaneously providing the vibration amplitude and phase angle relative to the keyphasor for that order, delivering key data for dynamic balance correction and precise fault localization.

  • Flexible and Powerful Protection Logic & Alarm Management System:

    • Four-Level Alarm Setpoints: Each dynamic channel can be configured with independent Alert+ (High Alert), Alert- (Low Alert), Danger+ (High Danger), and Danger- (Low Danger) setpoints, each with independently adjustable delay, hysteresis, and latching functions to effectively filter interference and prevent false trips.

    • Adaptive Monitoring: Alert and Danger limits can be automatically adjusted based on machine speed (or other external process parameters via a V/F converter). This function is particularly important during startup/shutdown, as it can automatically raise alarm thresholds in critical speed regions to avoid unnecessary protective actions.

    • Direct Trip Multiply (TM) & Danger Bypass (DB): Via external discrete signals, protection limits can be quickly multiplied by a coefficient (TM), or danger relay outputs can be temporarily inhibited (DB), providing flexible control for operation and maintenance.

    • Advanced Logic Combination Functions: Features powerful built-in programmable logic, offering up to 8 Basic Logic and 4 Advanced Logic function blocks. Users can combine conditions from any channel (alarms, dangers, sensor OK status, external inputs) using "AND", "OR", "M out of N" voting, and other logical operations to build complex redundant protection or voting shutdown logic, meeting high-safety application requirements.

  • Integrated Power Supply & Active Diagnostics System:

    • The card integrates isolated +27.2V, -27.2V, +15V multi-channel power supplies to directly power various industrial sensors such as IEPE accelerometers, eddy current probes, and magnetic speed sensors, simplifying external wiring and power management.

    • The unique "OK System" continuously monitors each sensor signal chain, reliably diagnosing faults such as sensor open circuit, short circuit, broken signal wire, or power supply abnormality. It reports these promptly via independent channel OK alarms and a common card OK alarm, ensuring the reliability of the monitoring system itself.

  • Convenient Engineering Implementation & Maintenance Features:

    • Front-Panel Diagnostic Interface: Provides 6 high-quality BNC connectors (4 dynamic + 2 speed) for direct connection to an oscilloscope or portable data collector, allowing engineers to perform online signal verification, fault diagnosis, and system performance testing without interrupting the protection function.

    • Intuitive Multi-Level Status Indication: The front panel is equipped with a complete set of color LED indicators. A global DIAG/STATUS light displays the overall health of the card pair, while six channel status lights indicate the signal validity, alarm status, and channel inhibit status for each corresponding channel, providing clear on-site operational status at a glance.

    • Hot-Swappable: Allows installation or replacement of the card in a powered-on VM600 system, greatly enhancing system availability and supporting online maintenance and rapid recovery.

  • Rich Output Interfaces & System Integration Capabilities:

    • Analog Outputs: Through the paired IOC4T card, it provides 4 isolated 0-10V or 4-20mA analog outputs, sending processed continuous signals like vibration values or gap voltage to the plant DCS, PLC, or historical database for trend analysis and process monitoring.

    • Relay Control: Alarm logic can directly drive the 4 Form C relays on the IOC4T card or, via the rack's backplane Open Collector (OC) Bus, drive expansion relay cards (e.g., the 16-channel RLC16 or the 8-channel IRC4), enabling flexible shutdown and alarm logic.

    • Dual-Path Configuration: Supports local configuration via the front-panel RS-232 serial port and remote networked configuration, monitoring, and data communication via the VME bus (requires a CPUx controller card installed in the rack), easily integrating into the plant-wide monitoring network.

  • Strict Adherence to Safety & Quality Standards: The design and manufacturing of this "Standard" version MPC4 card comply with international standards IEC 61508 (Functional Safety) and ISO 13849 (Safety of Machinery), making it suitable for applications requiring up to SIL 1 / PL c Safety Integrity Levels. It has obtained the relevant certifications, providing trustworthy safety assurance for critical equipment.

3. Typical Application Areas

The MPC4 card pair is an indispensable key safety component in the energy, process industry, and major equipment sectors, widely used in:

  • Power Industry: Coal/gas-fired steam turbines, turbo-generators, hydro-generators, large feedwater pumps, forced/induced draft fans.

  • Oil, Gas & Chemicals: Natural gas pipeline centrifugal compressors, refinery wet gas compressors, offshore platform gas turbines, high-speed reciprocating compressors.

  • Basic Industries & Manufacturing: Large air compressors, sintering fans, blast furnace blowers, turbo-expanders, critical process pumps.

  • Marine & Offshore Engineering: Ship main propulsion turbine sets, marine diesel or gas turbine generators, reduction gearboxes.

Its core function is to provide independent, continuous, fail-safe machinery protection while also serving as a reliable data source for implementing predictive maintenance.

4. Brief Operating Principle

The MPC4 card follows a precise real-time processing pipeline:

  1. Signal Acquisition & Primary Conditioning: Analog signals from field sensors (via IOC4T) are received. Current signals are converted to voltage via a precision sampling resistor. The signal then undergoes programmable gain amplification/attenuation and is split into AC (dynamic variable) and DC (static offset) paths.

  2. Digitization & Core Processing:

    • AC Path: The signal passes through anti-aliasing filtering and is digitized by a high-speed ADC. The DSP, according to user configuration, performs digital integration/differentiation, optional broadband or narrowband digital filtering, and the specified rectification operation (e.g., calculating RMS value).

    • DC Path: The signal undergoes low-pass filtering and ADC sampling, after which the static value (e.g., probe gap voltage) is calculated by the DSP.

  3. Monitoring Comparison & Logic Decision: The processed AC dynamic value (e.g., overall vibration) and DC static value are compared in real-time against user-preset multi-level alarm/danger limits. Simultaneously, the DC value is continuously monitored by the "OK System" to ensure sensor chain integrity. All comparison results (alarm, danger, OK status) are updated in real-time.

  4. Logic Combination & Final Output: The raw statuses of individual channels are fed into the programmable logic unit, combined according to preset strategies (e.g., 1-out-of-2 shutdown logic), generating the final protection command. Based on these commands:

    • Relay contacts on the IOC4T or external relay cards are controlled.

    • Processed engineering values are converted into standard analog signals via DAC for output.

    • The status of all front-panel LEDs is updated in real-time, providing intuitive local indication.

5. Status Indicator Interpretation

The MPC4 front-panel LEDs serve as an important local HMI:

  • DIAG/STATUS (Card Diagnostic Light): Multi-color light. Green Continuous = Normal operation; Yellow Continuous = TM function active; Red Continuous = DB function active; Green Blinking = Configuring or channel has input signal error; Yellow/Red Blinking = Configuration error or card hardware/firmware fault (red blinking has highest priority).

  • Channel Status Lights (RAW OUT 1-4, TACHO OUT 1-2): One multi-color light per channel.

    • Measurement Channels: Green Continuous = Normal; Green Blinking = Sensor OK fault; Yellow Continuous/Blinking = Alert alarm active; Red Continuous/Blinking = Danger alarm active; Slow Green Blink (~1Hz) = Channel is "Inhibited".

    • Speed Channels: Green Continuous = Normal; Green Blinking = Sensor OK fault or invalid signal; Yellow Continuous = Alert alarm active; Slow Green Blink = Channel is "Inhibited".

6. System Integration & Selection Guidance

As a mainstream "Standard" version, the typical system configuration for the MPC4 200-510-076-114 is as follows:

  1. Essential Core: 1 x MPC4 Card + 1 x matching IOC4T Card (recommended PNR 200-560-000-114 or newer), forming one card pair.

  2. Installation Carrier: The card pair is installed in the designated slots of a VM600 Series Rack (e.g., ABE04x).

  3. Function Expansion:

    • If more relay outputs are needed, add RLC16 or IRC4 relay cards.

    • For network connectivity and advanced data handling, a CPUx Series Communication Controller Card (e.g., CPUUR, CPUUM) must be installed in the rack.

  4. Software Tool: Use the official Meggitt VM600 MPSx series configuration software to set, commission, and monitor all parameters of the card pair via RS-232 or Ethernet.

Version Identification: The Standard version MPC4 card's front-panel lower handle label features white "MPC 4" text on a blue background. In the VM600 MPSx software (v2.6.x and above) project tree, this card appears as an "MPC4" device node.


Important Note: The MPC4 200-510-076-114 is a recommended model with full functionality, RoHS compliance, and 50Ω output impedance, suitable for most new and retrofit projects. For scenarios requiring a mix of safety protection cards and advanced diagnostic cards (e.g., XMx16) in the same rack with strict functional safety (SIL) certification requirements, the functionally trimmed MPC4SIL (Safety version) should be selected. For specific selection, always refer to the latest official documentation and consult Meggitt technical support.


Specification Category Detailed Parameter Detailed Description & Notes
Dynamic Signal Inputs
Channels: 4 (CH1-CH4), Fully Isolated & Programmable
Input Type Voltage or Current Software selectable, supports AC+DC coupled signals.
Voltage Range (DC) 0 to +20 V or 0 to -20 V
Voltage Range (AC) ±10 V (peak, maximum)
Common Mode Voltage Range -50 V to +50 V
Common Mode Rejection Ratio ≥ 60 dB @ 50 Hz
Input Impedance 200 kΩ (for voltage input)
Current Input Range (DC) 0 to 25 mA
Current Input Range (AC) ±8 mA (maximum)
Analog Bandwidth (-3dB) DC to 60 kHz Applicable in Raw Bus sharing mode.
AC Freq. Range (No Integration) 0.1 Hz to 10 kHz For direct velocity or displacement measurement.
AC Freq. Range (With Integration) 2.5 Hz to 10 kHz For integrating acceleration to velocity.
Current Measuring Resistor 324.5 Ω For current-to-voltage conversion.
Speed/Keyphasor Inputs*
Channels: 2 (TACHO 1, 2)
Triggering Method Rising / Falling Edge Threshold Trigger Software configurable.
Dynamic Trigger Thresholds Rising = (2/3) × Vpp, Falling = (1/3) × Vpp Automatically adapts based on signal amplitude.
Tachometer Range Raw Input: 0.016 Hz to 50 kHz
Processed Output: 0.016 Hz to 1092 Hz (1 to 65,535 RPM)
Supports gear tooth pulse input.
Input Voltage Range 0.3 Hz - 10 kHz: 0.4 - 500 Vpp
10 kHz - 50 kHz: 2.0 - 500 Vpp
Compatible with proximity switches, magnetic pickups, TTL signal sources.
Min. Reliable Trigger Voltage Square Wave (10 Hz-10 kHz): 0.8 Vpp
Sine Wave (1 Hz-10 Hz): 2.0 Vpp

Buffered Signal Outputs

Output Signals Sensor "Raw" analog/digital signals For external diagnostics and analysis.
Output Interface MPC4 Front-Panel BNC, IOC4T Rear-Panel Screw Terminals Dual access, convenient and flexible.
Output Impedance 50 Ω Important characteristic of model 076-114 and later, providing excellent signal integrity.
Dynamic Channel Transfer Ratio Voltage Input: 1 V/V
Current Input: 0.3245 V/mA
Output is a buffered mirror of the input signal.
Speed Channel Output 0 to 5 V, TTL-compatible level Front-panel BNC output.
Analog Outputs (IOC4T)

Output Channels 4 channels (DC OUT 1-4) Represent final processed engineering values.
Output Type & Range 4 to 20 mA or 0 to 10 V Selected independently per channel via IOC4T jumpers.
Over-Range Linear Output Supports linear output beyond 4-20mA/0-10V range Current: ~0-23.1 mA; Voltage: ~-2.5-11.9 V.
Signal Processing Functions

Broadband Processing High-pass, Low-pass, Band-pass filters selectable Attenuation slope: 6 to 60 dB/octave (programmable).
Narrowband Tracking Processing* Constant Q filter (Q = 28) Frequency Range: 0.15 Hz to 10 kHz

Order Extraction: 1/3X, 1/2X, 1X, 2X, 3X, 4X

Phase Error: ≤ ±6° (max), ≤ ±1° (typical, 1X order)
Relative Shaft Vibration Proc. Vibration Freq.: 0.1 Hz - 10 kHz; Gap/Position: DC - 1 Hz Features initial electrical gap compensation.
Amplitude Accuracy ±1% of full scale (typical, broadband processing)
Linearity Error ≤ ±1%
Alarm & Logic

Alarm Setpoints (Measurement) Alert+, Alert-, Danger+, Danger- Each point independently programmable.
Alarm Setpoints (Speed) Alert+, Alert-
Adjustable Parameters Limit, Delay, Hysteresis, Latching
Adaptive Monitoring Supported Automatically adjusts alarm limits based on speed or other parameters.
Direct Trip Multiply (TM)* Supported External TM signal controls coefficient (0.1-5.0) switching.
Danger Bypass (DB)* Supported External DB signal temporarily inhibits danger relay action.
Channel Inhibit* Supported Software-controlled temporary masking of a specified channel's protection output.
Logic Combinations 8 Basic Logic + 4 Advanced Logic Supports AND, OR, "M out of N" voting, etc.
OK System Diagnostics

Monitoring Principle Checks DC level of the sensor signal chain
Diagnostic Thresholds Configurable Upper and Lower Limits
Voltage Input OK Range ±20 V DC
Current Input OK Range 0 to 23 mA
Fault Confirmation Time 250 ms (fixed) Prevents noise false alarms.
System Response Time < 100 ms
Electrical Characteristics

Card Operating Power +5 VDC, ±12 VDC Supplied by the VM600 rack.
Typical Power Consumption +5V: 12.5W (typical) + ~1W per sensor
±12V: Max 2.5W

Sensor Power Supply Output +27.2 V (±5%), -27.2 V (±5%), +15.0 V (±5%) Max output current per channel: 25 mA.
Overcurrent Protection +5 V line: 11.0 A
Environmental Specifications

Operating Temperature -25°C to +65°C
Storage Temperature -40°C to +85°C
Operating Humidity 0 to 90% RH, non-condensing
Communications & Configuration

Configuration Interface RS-232 Serial Port (MPC4 front panel)
VME Bus (via CPUx card)
076-114 supports dual configuration modes.
MPC4 ↔ IOC4T Bus Dedicated high-speed parallel bus similar to Industry Pack (IP)
Host Communication Supports Ethernet and mainstream fieldbus protocols via CPUx card
Physical Attributes

Dimensions (H x W x D) 6U x 20 mm x 187 mm Standard VME Eurocard size.
Weight Approx. 0.40 kg
Certifications & Compliance

EMC IEC/EN 61000-6-2, IEC/EN 61000-6-4
Electrical Safety IEC/EN 61010-1
Functional Safety Compliant with IEC 61508 (SIL 1) & ISO 13849-1 (PL c) "Standard" version certification.
Environmental RoHS Compliant Core compliance mark for version 076-114.
Other Certifications CE, EAC (Eurasian Union)
Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.