Bently Nevada 330500-00-04 Velomitor Piezo-velocity Sensor

  • Bently Nevada

  • 330500-00-04

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The Bently Nevada 330500-00-04 is a specialized configuration of the acclaimed 330500 Velomitor Piezo‑velocity Sensor, meticulously engineered for critical machinery monitoring applications that demand dual hazardous area certifications—both CSA (North America) and ATEX (Europe) —while offering unparalleled mounting flexibility by excluding a factory‑supplied thread adapter. This variant features no mounting adapter (suffix -00), leaving the sensor’s native 3/8‑24 UNF‑2B body thread exposed, and carries multiple approvals (suffix -04), encompassing CSA certification for the United States and Canada, as well as ATEX certification for European and international markets. It is the ultimate choice for global projects where equipment may be deployed across different regulatory jurisdictions, and where users prefer to use existing mounting holes matching the 3/8‑24 thread, custom adapters, or direct mounting without the cost of a pre‑installed adapter.

The 330500 series is a state‑of‑the‑art piezoelectric velocity sensor with embedded integrated electronics, designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration on rotating machinery. Unlike traditional velocity transducers that rely on moving coils and mechanical springs, the 330500 employs a solid‑state design with no moving parts, offering superior reliability, extended service life, and the ability to be mounted in any orientation—vertically, horizontally, or at any angle—without performance degradation.

The 330500-00-04 provides a velocity output of 100 mV/in/s (3.94 mV/mm/s) with a frequency response from 4.5 Hz to 5 kHz (±3 dB) and a velocity range of 50 in/s peak (1270 mm/s) . Its robust construction includes a hermetically sealed 316L stainless steel case, a 2‑pin MIL‑C‑5015 connector, and a wide operating temperature range from -55°C to +121°C. The sensor is case‑isolated to prevent ground loops, and it offers excellent immunity to magnetic fields and base strain. The -00-04 variant is supplied without a mounting adapter, but carries both CSA and ATEX certifications, making it suitable for Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; and Class III hazardous locations (CSA) as well as Zone 0, Zone 1, Zone 2, and Zone 22 (ATEX) with entity parameters that enable intrinsic safety operation.

This introduction focuses exclusively on the 330500-00-04 configuration, highlighting its unique value as the only adapter‑free, dual‑certified Velomitor in the Bently Nevada portfolio. It compares this variant with other adapter options (e.g., 330500-01-04 with 1/2‑20 UNF adapter) and with single‑certification versions (e.g., 330500-00-01 for CSA, 330500-00-02 for ATEX) to guide proper selection for global hazardous‑area applications where mounting flexibility and multi‑region compliance are paramount.

Functional Description and Dual Certification Significance

The 330500-00-04 accelerometer operates on the piezoelectric principle, where a piezoelectric crystal generates an electrical charge proportional to the acceleration of the sensor housing. An internal charge amplifier and integrator circuit convert this acceleration signal into a velocity signal, which is then output as a low‑impedance voltage. The output bias voltage is nominally -12 V dc (referenced to Pin A), which allows the sensor to be powered by the same two‑wire interface used for many industrial monitoring systems. The sensor requires a power supply of -24 V dc (nominal) and draws a bias current of 2 mA (typical), with the dynamic signal superimposed on the bias voltage.

The integration of the electronics within the sensor housing eliminates the need for external signal conditioning, simplifies installation, and reduces the risk of noise pickup. The solid‑state design ensures that there are no moving parts to wear out, providing long‑term stability and repeatability. The 330500-00-04 is designed to be mounted directly on the machine casing or bearing housing using the body thread. The standard sensor body incorporates a 3/8‑24 UNF‑2B mounting hole, which is a common thread size for many industrial mounting bases and adapters. By choosing the -00 adapter option, the user receives the sensor without a pre‑installed adapter, offering maximum flexibility to select a third‑party adapter or to mount the sensor directly into a threaded hole that matches the body thread.

The -04 certification adds both CSA and ATEX approvals, making it a truly global solution. The sensor carries the following markings (as per the datasheet):

  • CSA: Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III; Temperature Class T3; -55°C ≤ Tamb ≤ +121°C.

  • ATEX: Ex ia IIC T3 Ga (Zone 0/1), Ex ec IIC T3 (Zone 2), Ex tc IIC T200°C Dc (Zone 22); -55°C ≤ Ta ≤ +121°C.

Entity Parameters (identical for both certifications):

Parameter

Value

Ui (maximum input voltage)

28 V

Ii (maximum input current)

100 mA

Pi (maximum input power)

0.84 W

Ci (internal capacitance)

10.8 nF

Li (internal inductance)

0 μH

The dual certification eliminates the need to stock separate sensors for North American and European hazardous areas, simplifying inventory management and reducing the risk of using the wrong sensor in a given location. For global OEMs, EPCs, and end‑users with facilities on multiple continents, the 330500-00-04 offers a single part number that meets the most common intrinsic safety requirements worldwide.

The sensor’s frequency response covers the range from 4.5 Hz to 5 kHz (270 cpm to 300,000 cpm) within ±3 dB, and from 6.0 Hz to 2.5 kHz (360 cpm to 150,000 cpm) within ±0.9 dB. This wide bandwidth makes it suitable for both low‑speed and high‑speed machinery, including gearboxes and turbines with high blade‑pass frequencies. The velocity output is particularly advantageous for machinery protection because it provides a direct measure of vibration severity, which is often the parameter used in international standards (e.g., ISO 10816) for evaluating machine health.

The sensor's amplitude linearity is ±2% up to 6 in/s peak, and its transverse sensitivity is less than 5% of the axial sensitivity. The mounted resonant frequency exceeds 12 kHz, ensuring that the sensor's natural resonance does not interfere with the measurement band. The case‑isolated design prevents ground loops, and the hermetically sealed construction protects the electronics from moisture and contaminants.

Detailed Comparison with Other 330500 Configurations – Adapter and Approval Options

To assist in proper sensor selection, the following table compares the 330500-00-04 with other common configurations: the 330500-00-00 (no adapter, no approvals), the 330500-00-01 (no adapter, CSA), the 330500-00-02 (no adapter, ATEX), and the 330500-01-04 (1/2‑20 UNF adapter, multiple approvals). This comparison highlights the unique value of the -00-04 for flexible, dual‑certified installations.

Selection Guide – Key Differences

Feature / Option

330500-00-04

330500-00-00

330500-00-01

330500-00-02

330500-01-04

Mounting Adapter

None (body thread 3/8‑24 UNF‑2B)

None

None

None

1/2‑20 UNF

Agency Approvals

Multiple (CSA, ATEX)

None

CSA

ATEX

Multiple (CSA, ATEX)

Hazardous Area Suitability

Yes (CSA Div 1/2/Class II/III & ATEX Zone 0/1/2/22)

No

Yes (CSA)

Yes (ATEX)

Yes

Entity Parameters

Ui=28V, Ii=100mA, Pi=0.84W, Ci=10.8nF, Li=0µH

N/A

Same

Same

Same

Sensitivity

100 mV/in/s

Same

Same

Same

Same

Frequency Response

4.5 Hz – 5 kHz (±3 dB)

Same

Same

Same

Same

Velocity Range

50 in/s peak

Same

Same

Same

Same

Output Bias Voltage

-12 V dc ±3 V

Same

Same

Same

Same

Connector

2‑pin MIL‑C‑5015

Same

Same

Same

Same

Case Material

316L stainless steel

Same

Same

Same

Same

Temperature Range

-55°C to +121°C

Same

Same

Same

Same

Base Strain Sensitivity

0.005 in/s/mstrain

Same

Same

Same

Same

Typical Application

Flexible mounting in global hazardous areas with custom adapters or direct 3/8‑24 mounting

Flexible mounting in safe areas

Flexible mounting in North American hazardous areas

Flexible mounting in European hazardous areas

Global hazardous areas with 1/2‑20 mounting

Certifications

CSA, ATEX, FCC, EMC, RoHS, ABS

FCC, EMC, RoHS, ABS

CSA, FCC, EMC, RoHS, ABS

ATEX, FCC, EMC, RoHS, ABS

CSA, ATEX, FCC, EMC, RoHS, ABS

Ordering Part Number

330500-00-04

330500-00-00

330500-00-01

330500-00-02

330500-01-04

The 330500-00-04 is the most flexible dual‑certified configuration in the 330500 series. Choose this variant when:

  • You need both CSA and ATEX certifications for global hazardous area deployments.

  • You have an existing mounting hole that matches the 3/8‑24 UNF‑2B thread, or you plan to use a custom adapter not offered by Bently Nevada.

  • You want to minimize cost by omitting the adapter while still meeting multiple safety standards.

  • You prefer the body thread for direct mounting without an extra adapter.

If you need a specific adapter (e.g., 1/2‑20 UNF for quick‑connect mounts) with dual approvals, choose 330500-01-04. If you only need CSA or ATEX individually, choose -00-01 or -00-02 respectively.

Hardware Characteristics – Specific to 330500-00-04

Physical Dimensions and Mounting

  • Body Thread (exposed): 3/8‑24 UNF‑2B, with a minimum threaded depth of 6.4 mm (0.250 in) and a maximum drill depth of 14.0 mm (0.550 in). The sensor body includes a 15/16 inch hexagonal feature for tightening.

  • Diameter: 25.3 mm (0.995 in)

  • Height: 63.2 mm (2.49 in) (without adapter; with an adapter, the height increases)

  • Weight: 142 grams (5.0 oz) typical (without adapter)

  • Case Material: 316L stainless steel, hermetically sealed

  • Connector: 2‑pin MIL‑C‑5015 hermetically sealed receptacle, 316L stainless steel shell

  • Mounting Torque: 32‑46 kg·cm (24‑40 in‑lb) maximum (for the sensor body when tightened into a mounting hole)

Polarity and Wiring

The sensor has a 2‑pin connector. The pin assignment is:

  • Pin A: Signal + (positive output when the sensor case moves toward the connector)

  • Pin B: Common (return) and power supply negative (shield)

The output bias voltage is -12 V dc (±3 V) referenced to Pin A. The sensor requires a -24 V dc supply (nominal) with a bias current of 2 mA (typical). The dynamic signal is a velocity output superimposed on the bias voltage.

Cables and Maximum Length

The 330500-00-04 is compatible with the same two‑conductor shielded cables as all 330500 variants. For hazardous area installations, the cable must be suitable for intrinsic safety and must meet the entity parameter limits per both CSA and ATEX requirements. The recommended cable (part number 02173006) is 18 AWG twisted shielded bulk cable. For pre‑terminated cables, the following options are available (custom lengths in 1.0 ft increments):

Cable Part Number

Description

Min/Max Length

9571-NN

22 AWG twisted shielded with 2‑socket female connector and terminal lugs

2.0 – 99 ft

84661-NN

22 AWG armored cable with 2‑socket connector and terminal lugs

3.0 – 96 ft

89477-NN

18 AWG right‑angle 2‑socket plug and terminal lugs (compatible with 21128 housing)

2.0 – 99 ft

125065-NN

18 AWG with fluorosilicone elastomer boot, 2‑socket plug, terminal lugs

2.0 – 99 ft

Maximum cable length: 305 meters (1,000 ft) of cable (part number 02173006) with no signal degradation, provided the cable capacitance is within limits. For longer lengths, contact Bently Nevada Tech Support. The recommended cable length for a 50 g vibration at 10 kHz and cable capacitance of 200 pF/m is 208 ft (63 m). In hazardous areas, cable capacitance and inductance must be added to the sensor's Ci and Li, and the total must not exceed the barrier's limits for both CSA and ATEX.

Environmental and Electrical Specifications

  • Power Requirements: -24 V dc nominal, 2 mA bias current typical

  • Output Bias Voltage: -12 V dc ±3 V

  • Dynamic Output Impedance: < 2400 Ω

  • Operating Temperature: -55°C to +121°C (-67°F to +250°F)

  • Shock Survivability: 5,000 g peak maximum

  • Relative Humidity: 100% condensing (non‑submerged); case is hermetically sealed

  • Base Strain Sensitivity: 0.005 in/s/mstrain (very low, minimising errors from mounting surface flexure)

  • Magnetic Field Susceptibility: < 51 in/s/gauss at 50 gauss, 50‑60 Hz

  • Grounding: Case isolated (housing isolated from signal common)

Hazardous Area Compliance – CSA and ATEX Dual Certification

The 330500-00-04 is certified to both CSA and ATEX standards, as detailed below.

CSA Certification (North America):

  • Class I, Division 1, Groups A, B, C, D (flammable gases/vapors)

  • Class II, Groups E, F, G (combustible dusts)

  • Class III (ignitable fibers/flyings)

  • Temperature Class T3, with ambient temperature range -55°C ≤ Tamb ≤ +121°C.

  • Install per drawing 167537.

ATEX Certification (Europe):

  • Ex ia IIC T3 Ga – Intrinsic safety for Zone 0 (continuous presence of explosive gas) and Zone 1, Gas Group IIC (hydrogen, acetylene), Temperature Class T3 (≤200°C surface temperature).

  • Ex ec IIC T3 – Increased safety for Zone 2.

  • Ex tc IIC T200°C Dc – Dust protection for Zone 22.

  • Ambient temperature range: -55°C ≤ Ta ≤ +121°C.

Entity Parameters (identical for both):

Parameter

Value

Ui (maximum input voltage)

28 V

Ii (maximum input current)

100 mA

Pi (maximum input power)

0.84 W

Ci (internal capacitance)

10.8 nF

Li (internal inductance)

0 μH

Conditions of Safe Use:

  • For Zone 0/1 (ATEX) and Division 1 (CSA): The sensor must be connected to an associated intrinsically safe apparatus that meets the entity parameters. Cable type A or B per EN 60079‑25 (for ATEX) and appropriate cable parameters for CSA must be respected.

  • For Zone 2 (ATEX) and Division 2 (CSA): The supply electrical parameters shall not exceed the values in the table above.

  • The mating connector must provide at least IP54 ingress protection per applicable standards.

  • Transient protection shall be provided at a level not exceeding 140% of the peak rated voltage.

The dual certification allows the same sensor to be used in hazardous areas under both North American and European regulatory frameworks, simplifying logistics and reducing the risk of using uncertified equipment.

Installation Best Practices for 330500-00-04 in Global Hazardous Areas

  1. Intrinsic Safety Barrier – Always connect the sensor through a certified intrinsic safety barrier that meets the requirements of both CSA and ATEX (if used in respective jurisdictions). Ensure the barrier’s output parameters (Uo, Io, Po) do not exceed Ui, Ii, and Pi.

  2. Cable Selection and Length Calculation – The sensor’s Ci (10.8 nF) and Li (0 μH) must be added to the cable’s capacitance and inductance. The total must not exceed the barrier’s allowable cable parameters. Consult the barrier manufacturer’s documentation and ensure compliance with both CSA and ATEX cable parameter limits.

  3. Mounting Surface Preparation – Clean the mounting surface to remove paint, rust, or debris. Achieve a surface finish of 32 µin rms or better. Ensure the threaded hole matches the 3/8‑24 UNF‑2B thread and is perpendicular to the measurement axis. Apply anti‑seize compound if required, and torque the sensor body to 32‑46 kg·cm (24‑40 in‑lb). Do not use the connector body to apply torque; use a wrench on the 15/16 inch hex flats.

  4. Cable Connection – Align the 2‑pin connector (Pin A and Pin B) and tighten the coupling nut securely. In hazardous areas, ensure the connector is properly mated and sealed (IP54 or better) to prevent ingress.

  5. Grounding – The case is isolated, so grounding is not required for the sensor body. However, the cable shield should be grounded at the power supply end (typically at the barrier) to minimize noise. Do not ground the shield at both ends to avoid ground loops.

  6. Environmental Protection – Although the sensor is IP68, the cable termination and connectors require additional protection (splash boots, conduit, etc.) for outdoor or wet locations.

Comparison with Other Dual‑Certified Options – Why Choose 330500-00-04?

  • vs. 330500-01-04 (with 1/2‑20 UNF adapter) – The -01-04 includes a 1/2‑20 UNF adapter, which is convenient for quick‑connect mounts (e.g., 46122-01). If you do not need this specific adapter, the -00-04 saves cost and provides the flexibility to use any adapter you choose, or to mount directly into a 3/8‑24 hole.

  • vs. 330500-00-01 (CSA only) and 330500-00-02 (ATEX only) – These single‑certification versions are suitable for installations in a single region. If your equipment moves between regions or you supply global projects, the -00-04 eliminates the need to maintain two separate part numbers and reduces the risk of using the wrong sensor.

  • vs. 330500-00-00 (no approvals) – The -00-04 adds critical safety compliance for hazardous areas, which is mandatory in many industries.

Ordering Information

When ordering the 330500-00-04, use the full part number exactly as shown:

  • 330500 – Base model (Velomitor Piezo‑velocity Sensor)

  • -00 – Mounting Thread Adapter: None (body thread 3/8‑24 UNF‑2B exposed)

  • -04 – Agency Approval: Multiple (CSA, ATEX)

Compatible Cables and Accessories for Hazardous Areas

Part Number

Description

02173006

Bulk cable (2 conductor 18 AWG twisted shielded) – specify length in feet

9571-NN

22 AWG cable with 2‑socket connector and terminal lugs

84661-NN

22 AWG armored cable

89477-NN

18 AWG right‑angle cable (compatible with 21128 housing)

125065-NN

18 AWG cable with fluorosilicone elastomer boot

100076

User Guide

89409-01

1/2‑20 UNF mounting adapter (spare)

89410-01

M8 x 1 mounting adapter

89411-01

1/4‑28 UNF mounting adapter

89412-01

1/4‑20 UNC mounting adapter

89413-01

1/4‑18 NPT mounting adapter (spares only)

46000-01

Magnetic Base (for temporary use, non‑hazardous)

46122-01

Quick Connect (for semi‑permanent mounting, uses 1/2‑20 adapter)

Note: The 330500-00-04 does not include a cable or adapter; order separately. Ensure cables and barriers are certified for both CSA and ATEX if used in respective jurisdictions.

Certifications and Compliance – Special Note

The 330500-00-04 carries both CSA and ATEX certifications, making it compliant with North American and European hazardous area requirements. It also complies with FCC Part 15, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU, China RoHS (EFUP 15 years), and ABS Marine. It is NOT certified to IECEx separately, but ATEX is harmonized with IECEx; for IECEx specific requirements, consult the factory.

Warranty and Support

The Bently Nevada 330500-00-04 is covered under the standard manufacturer’s warranty. For technical support, application assistance, or help with certification documentation, contact your local Bently Nevada representative or access the Bently Nevada Media Library at bntechsupport.com.

Specification Category

Details

Part Number

330500-00-04

Product Type

Velomitor Piezo‑velocity Sensor

Mounting Adapter

None (body thread 3/8‑24 UNF‑2B exposed)

Agency Approval Option

Multiple (CSA, ATEX)

Hazardous Area Certifications

CSA: Class I Div 1 Groups A‑D, Class II Groups E‑G, Class III; T3; -55°C ≤ Tamb ≤ +121°C. ATEX: Ex ia IIC T3 Ga, Ex ec IIC T3, Ex tc IIC T200°C Dc; -55°C ≤ Ta ≤ +121°C.

Entity Parameters

Ui=28 V, Ii=100 mA, Pi=0.84 W, Ci=10.8 nF, Li=0 μH

Sensitivity

3.94 mV/mm/s (100 mV/in/s) ±5%

Frequency Response

4.5 Hz – 5 kHz (270 – 300,000 cpm) ±3.0 dB; 6.0 Hz – 2.5 kHz (360 – 150,000 cpm) ±0.9 dB

Velocity Range

1270 mm/s (50 in/s) peak

Amplitude Linearity

±2% to 152 mm/s (6 in/s) peak

Transverse Sensitivity

< 5% of axial sensitivity

Mounted Resonant Frequency

> 12 kHz

Output Bias Voltage

-12 V dc ±3 V (referenced to Pin A)

Dynamic Output Impedance

< 2400 Ω

Broadband Noise Floor

0.004 mm/s (160 μin/s) rms nominal (4.5 Hz – 5 kHz)

Temperature Sensitivity

-14% to +7.5% typical over operating temperature range

Power Supply Voltage

-24 V dc nominal

Bias Current

2 mA typical

Grounding

Case isolated

Maximum Cable Length

305 m (1,000 ft) with recommended cable (02173006); derate for hazardous area

Operating Temperature

-55°C to +121°C (-67°F to +250°F)

Shock Survivability

5,000 g peak

Relative Humidity

100% condensing (hermetically sealed)

Base Strain Sensitivity

0.005 in/s/mstrain

Magnetic Field Susceptibility

< 51 in/s/gauss (50 gauss, 50‑60 Hz)

Case Material

316L stainless steel

Connector

2‑pin MIL‑C‑5015 hermetically sealed, 316L stainless steel shell

Weight (no adapter)

142 g (5.0 oz) typical

Diameter

25.3 mm (0.995 in)

Height (no adapter)

63.2 mm (2.49 in)

Body Mounting Thread

3/8‑24 UNF‑2B

Mounting Torque

32‑46 kg·cm (24‑40 in‑lb) max

Polarity

Pin A positive when case moves toward connector

Maximum Use Altitude

2000 m (typical for industrial sensors)

IP Rating

Equivalent to IP68 (hermetically sealed case, dust‑tight and watertight for sensor only)

Compliance

CSA, ATEX 2014/34/EU, FCC Part 15, EMC 2014/30/EU, RoHS 2011/65/EU, China RoHS (EFUP 15 years), ABS Marine Vessels

Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.