The Acti9 iC60L A9F94302 is a three-pole miniature circuit breaker from Schneider Electric's Acti9 range, designed for low-voltage distribution systems. It is rated at 2 A with a C-characteristic thermal-magnetic trip unit, making it suitable for circuits with moderate inrush currents. The breaker delivers a short-circuit breaking capacity of up to 100 kA at 220–240 V AC under EN/IEC 60947-2 and 15,000 A at 400 V AC under EN/IEC 60898-1. It complies with both industrial and residential standards. Key features include the VisiTrip fault indicator, which helps locate the faulted circuit quickly, and the VisiSafe green strip, which confirms that contacts are physically open for safe downstream maintenance. Its fast-closing mechanism, independent of the toggle, extends service life, with ratings of 10,000 electrical and 20,000 mechanical cycles. The device has a 500 V AC rated insulation voltage, a limitation class of 3, and a pollution degree of 3. It clips onto a 35 mm DIN rail and occupies six 9 mm pitches (54 mm width). Dimensions are 85 mm (H) × 54 mm (W) × 78.5 mm (D), with a net weight of 0.375 kg. It offers IP20 terminal protection (IP40 when enclosed), operates from -35 °C to +70 °C, and comes in white (RAL9003). With overvoltage category IV and a 54% recyclability potential, it is a durable and sustainable choice for three-phase protection.

Parameter

Details

General

Product Model

A9F94302

Range

Acti9

Product Name

Acti9 iC60

Product or Component Type

Miniature circuit-breaker (MCB)

Device Short Name

iC60L

Device Application

Distribution

Poles Description

3P

Number of Protected Poles

3

Rated Current (In)

2 A

Network Type

AC / DC

Trip Unit Technology

Thermal-magnetic

Curve Code

C

Utilisation Category

Category A conforming to EN/IEC 60947-2

Standards

EN/IEC 60947-2, EN/IEC 60898-1

Breaking Capacity

– EN/IEC 60947-2 (AC)

100 kA at 220…240 V AC 50/60 Hz

– EN/IEC 60898-1 (AC)

15,000 A at 400 V AC 50/60 Hz

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz conforming to EN/IEC 60947-2

Rated Impulse Withstand Voltage (Uimp)

6 kV conforming to EN/IEC 60947-2

Limitation Class

3 conforming to EN/IEC 60898-1

Durability & Signalling

Mechanical Durability

20,000 cycles

Electrical Durability

10,000 cycles

Contact Position Indicator

Yes

Control Type

Toggle

Local Signalling

Trip indicator

Mounting & Physical

Mounting Mode

Clip-on

Removable Comb Busbar

Installed

Mounting Support

35 mm DIN rail

Comb Busbar and Distribution Block Compatibility

Top or bottom: Yes

Connection Pitch

18 mm between phases

Number of 9 mm Pitches

6

Height

85 mm

Width

54 mm

Depth

78.5 mm

Net Weight

0.375 kg

Colour

White (RAL9003)

Terminals & Connections

Connection Type

Single terminal (top or bottom)

Rigid Conductor (copper)

1…25 mm²

Flexible Conductor (copper)

1…16 mm²

Flexible with Ferrule (copper)

1…16 mm²

Flexible (copper or aluminium, with ring terminal and accessory)

1.0 cable

Wire Stripping Length

14 mm for top or bottom connection

Tightening Torque

2 N·m top or bottom

Earth-leakage Protection

Separate block

Environmental & Protection Ratings

IP Degree of Protection

IP20 conforming to IEC 60529
IP40 in modular enclosure (Insulation class II) conforming to IEC 60529

Pollution Degree

3 conforming to EN/IEC 60947-2

Overvoltage Category

IV

Tropicalisation

2 conforming to IEC 60068-1

Relative Humidity

95% at 55 °C

Operating Altitude

0…2000 m

Ambient Air Temperature for Operation

-35…70 °C

Ambient Air Temperature for Storage

-40…85 °C

Sustainability & Compliance

Halogen-free (plastic parts)

Halogen free plastic parts product

PVC-free

Yes

Silicone-free

No

PFAS

Item contains PFAS Chemicals

Recyclability Potential

54%

EU RoHS Directive

Compliant

REACH Regulation

Reference contains SVHC above threshold

SCIP Number

26ff71d1-98cf-4280-8725-455b9a6b2fb9

Packaging with Recycled Cardboard

Yes

Packaging without Single-use Plastic

Yes

WEEE Label

Required for EU disposal (separate collection)

Logistics & Packaging

Package 1 (PCE)

1 pc; H 5.5 cm × W 7.5 cm × L 9.0 cm; weight 337.3 g

Package 2 (BB1)

4 units; H 8.5 cm × W 10.0 cm × L 22.0 cm; weight 1.413 kg

Package 3 (S03)

44 units; H 30.0 cm × W 30.0 cm × L 40.0 cm; weight 15.951 kg

Carbon Footprint (Lifecycle)

Total

34 kg CO₂ eq.

Manufacturing (A1-A3)

2 kg CO₂ eq.

Distribution (A4)

0 kg CO₂ eq.

Installation (A5)

0 kg CO₂ eq.

Use Phase (B2, B3, B4, B6)

31 kg CO₂ eq.

End-of-life (C1-C4)

1 kg CO₂ eq.

Environmental Disclosure

Product Environmental Profile available

Previous: 
Next: 

Related Products

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.