Schneider
A9F94263
IN STOCK
T/T
XIAMEN
| Availability: | |
|---|---|
| Quantity: | |
The A9F94263 is a two‑pole (2P) miniature circuit breaker from Schneider Electric’s Acti9 iC60L range, designed specifically for high‑current industrial and commercial applications. Rated at 63 A with a C‑curve tripping characteristic (magnetic threshold at 8 × In), this device delivers robust protection against overloads and short‑circuits while tolerating moderate inrush currents, making it well‑suited for large motor feeders, lighting distribution, HVAC systems, and industrial control panels. As a 2‑pole device, it ensures simultaneous disconnection of both lines, providing complete isolation and enhanced safety in single‑phase AC or DC installations. This MCB complies with the industrial standard EN/IEC 60947‑2, offering a breaking capacity of up to 15 kA at 380‑415 V AC and 30 kA at 220‑240 V AC, ensuring reliable fault clearing in demanding environments. The breaker incorporates Schneider’s signature VisiTrip indicator, which visually pinpoints the tripped pole to reduce fault‑finding time, and the VisiSafe green strip that provides undeniable proof of contact separation – a vital safety feature for downstream maintenance. Its quick‑make/quick‑break mechanism, independent of handle position, ensures consistent performance over 10,000 electrical and 20,000 mechanical cycles. With a compact 36 mm width (4 modular pitches) and DIN‑rail clip‑on mounting, it optimises panel space. The double‑tunnel terminals accept conductors up to 35 mm² (rigid) and 25 mm² (flexible) with a 3.5 N·m tightening torque. Operating reliably from -35 °C to +70 °C, this MCB is built with PVC‑free materials and achieves 54% recyclability, though it contains halogen above thresholds. Its total lifecycle carbon footprint is quantified at 63 kg CO₂ eq., reflecting Schneider Electric’s transparent environmental reporting.
Parameter | Details |
|---|---|
General | |
Product Model | A9F94263 |
Range | Acti9 |
Product Name | Acti9 iC60 |
Device Short Name | iC60L |
Device Application | Distribution |
Poles Description | 2P |
Number of Protected Poles | 2 |
Rated Current (In) | 63 A |
Network Type | AC / DC |
Trip Unit Technology | Thermal‑magnetic |
Tripping Curve | C |
Magnetic Tripping Limit | 8 x In ± 20% |
Suitability for Isolation | Yes (conforming to EN/IEC 60947‑2) |
Utilisation Category | Category A (EN/IEC 60947‑2) |
Breaking Capacity (Icu) – EN/IEC 60947‑2 | |
– 12…133 V AC 50/60 Hz | 70 kA |
– 220…240 V AC 50/60 Hz | 30 kA |
– 380…415 V AC 50/60 Hz | ≤ 15 kA |
– 440 V AC 50/60 Hz | ≤ 10 kA |
– ≤125 V DC | ≤ 20 kA |
Service Breaking Capacity (Ics) – EN/IEC 60947‑2 | |
– 12…133 V AC | 35 kA (50% x Icu) |
– 220…240 V AC | ≤ 15 kA (50% x Icu) |
– 380…415 V AC | ≤ 7.5 kA (50% x Icu) |
– 440 V AC | ≤ 5 kA (50% x Icu) |
– ≤125 V DC | ≤ 20 kA (100% x Icu) |
Limitation Class | Not applicable (standard does not include limitation class) |
Rated Operational Voltage (Ue) | 12…133 V AC 50/60 Hz |
Rated Insulation Voltage (Ui) | 500 V AC 50/60 Hz (EN/IEC 60947‑2) |
Rated Impulse Withstand Voltage (Uimp) | 6 kV (EN/IEC 60947‑2) |
Network Frequency | 50/60 Hz |
Durability | |
Mechanical Durability | 20,000 cycles |
Electrical Durability | 10,000 cycles |
Contact Position Indicator | Yes (toggle) |
Local Signalling | Trip indicator (VisiTrip) |
Mounting & Physical | |
Mounting Mode | Clip‑on (35 mm DIN rail) |
Removable Comb Busbar | Installed; compatible top or bottom |
Connection Pitch | 18 mm between phases |
Number of Pitches | 4 (36 mm total width) |
Width | 36 mm |
Height | 85 mm |
Depth | 78.5 mm |
Net Weight | 0.25 kg |
Colour | White (RAL9003) |
Terminals & Connections | |
Connection Type | Single terminal (top or bottom), double tunnel |
Rigid Conductor (copper) | 1…35 mm² |
Flexible Conductor (copper) | 1…25 mm² |
Flexible with Ferrule (copper) | 1…25 mm² |
With Ring Terminal (Cu/Al) | Via accessory |
Multiple Conductors (with accessory) | Up to 3 x 16 mm² rigid or 3 x 10 mm² flexible |
Wire Stripping Length | 14 mm (top or bottom) |
Tightening Torque | 3.5 N·m (top or bottom) |
Earth‑leakage Protection | Separate add‑on block (Vigi iC60) required |
Environmental & Protection Ratings | |
Standards Compliance | EN/IEC 60947‑2 only (no EN/IEC 60898‑1 certification) |
IP Degree (terminals) | IP20 (IEC 60529) |
IP in Enclosure | IP40 (Insulation class II) |
Pollution Degree | 3 (EN/IEC 60947‑2) |
Overvoltage Category | IV |
Tropicalisation | 2 (IEC 60068‑1) |
Relative Humidity | 95% at 55°C |
Operating Altitude | 0…2000 m |
Operating Temperature | -35°C … +70°C |
Storage Temperature | -40°C … +85°C |
Sustainability & Compliance | |
Halogen‑free status | Product contains halogen above thresholds (not halogen‑free) |
PVC‑free | Yes |
Silicone‑free | No |
Recyclability Potential | 54% |
EU RoHS Directive | Compliant |
REACH SVHC | Contains SVHC above threshold |
SCIP Number | 26F71d1‑98cf‑4280‑8725‑455b9a6b2fb9 |
Packaging with recycled cardboard | Yes |
Packaging without single‑use plastic | Yes |
WEEE Label | Required for EU disposal (separate collection) |
Repair / Take‑back | No / No |
Logistics | |
Country of Origin | Not specified in provided data |
Warranty | 18 months |
Package 1 (Single unit) | 1 pc; dimensions not fully specified; weight 264 g |
Package 2 (Box of 6) | 6 units; H 8.1 cm × W 9.8 cm × L 22.5 cm; weight 1.640 kg |
Package 3 (Pallet of 66) | 66 units; H 30.0 cm × W 30.0 cm × L 40.0 cm; weight 18.580 kg |
Carbon Footprint (Lifecycle) | |
Total | 63 kg CO₂ eq. |
Manufacturing (A1‑A3) | 2 kg CO₂ eq. |
Distribution (A4) | 0 kg CO₂ eq. |
Installation (A5) | 0 kg CO₂ eq. |
Use Phase (B2, B3, B4, B6) | 60 kg CO₂ eq. |
End‑of‑life (C1‑C4) | 0.8 kg CO₂ eq. |
Environmental Disclosure | Product Environmental Profile available |