Schneider
A9F77206
IN STOCK
T/T
XIAMEN
| Availability: | |
|---|---|
| Quantity: | |
The A9F77206 is a 6‑ampere, double‑pole (2P) miniature circuit breaker from Schneider Electric’s Acti9 iC60N series, featuring a C‑curve tripping characteristic (magnetic threshold at 8 × In). The C‑curve offers an optimal balance between overload protection and tolerance of moderate inrush currents, making it a versatile solution for general‑purpose distribution – including lighting circuits, socket outlets, small power feeders, and control panels in commercial, industrial, and residential installations. With both poles protected, this 2‑pole device ensures simultaneous disconnection of both lines in single‑phase AC systems or DC applications, significantly enhancing safety and isolation integrity. This MCB provides a rated ultimate breaking capacity of 20 kA at 220‑240 V AC under the industrial standard EN/IEC 60947‑2, and 6 kA at 400 V AC per the residential norm EN/IEC 60898‑1, ensuring reliable fault interruption across a broad range of applications. Certified to both standards, it offers flexible integration into mixed‑use projects. Designed with Class‑2 insulation for superior operator protection, the breaker also coordinates fully with Acti 9 RCDs and Compact NSX MCCBs, simplifying system design. The device incorporates the intuitive VisiTrip fault‑finder window, which instantly identifies the tripped pole to accelerate troubleshooting, and the VisiSafe green strip that delivers unmistakable visual confirmation of contact opening – a critical safety check for maintenance personnel. Its quick‑make/quick‑break mechanism, independent of handle position, ensures consistent switching performance over 10,000 electrical and 20,000 mechanical cycles. Despite its 6 A rating, the breaker maintains a compact 36 mm width (4 modular pitches) and clips onto DIN rails, saving valuable panel space. The double‑tunnel terminals accept rigid conductors up to 25 mm² and flexible up to 16 mm² with a 2 N·m tightening torque, and the device offers IP20 terminal protection and IP40 when enclosed. Operating reliably from -35 °C to +70 °C, it is built with PVC‑free materials, though it contains halogen above thresholds. Achieving a 54% recyclability rate and a total lifecycle carbon footprint of 16 kg CO₂ eq., this MCB aligns with Schneider Electric’s sustainable energy management objectives.
Parameter | Details |
|---|---|
General | |
Product Model | A9F77206 |
Range | Acti9 |
Product Name | Acti9 iC60 |
Device Short Name | iC60N |
Device Application | Distribution |
Poles Description | 2P |
Number of Protected Poles | 2 |
Rated Current (In) | 6 A |
Network Type | AC / DC |
Trip Unit Technology | Thermal‑magnetic |
Tripping Curve | C |
Magnetic Tripping Limit | 8 x In ± 20% |
Suitability for Isolation | Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2) |
Utilisation Category | Category A (EN/IEC 60947‑2) |
Breaking Capacity (Icu) | |
– EN/IEC 60947‑2 (AC) | 20 kA at 220…240 V AC 50/60 Hz (from product image; full voltage range not specified) |
– EN/IEC 60898‑1 (AC) | 6,000 A at 400 V AC 50/60 Hz |
– DC ratings | Not specified in provided documents; consult full datasheet |
Service Breaking Capacity (Ics) | Not explicitly stated; refer to standard series data (typically 100% or 75% of Icu) |
Limitation Class | Class 3 (EN/IEC 60898‑1) |
Rated Operational Voltage (Ue) | 12…60 V AC 50/60 Hz |
Rated Insulation Voltage (Ui) | 500 V AC 50/60 Hz (EN/IEC 60947‑2) |
Rated Impulse Withstand Voltage (Uimp) | 6 kV (EN/IEC 60947‑2) |
Network Frequency | 50/60 Hz |
Durability | |
Mechanical Durability | 20,000 cycles |
Electrical Durability | 10,000 cycles |
Contact Position Indicator | Yes (toggle) |
Local Signalling | Trip indicator (VisiTrip) |
Mounting & Physical | |
Mounting Mode | Clip‑on (35 mm DIN rail) |
Removable Comb Busbar | Installed; compatible top or bottom |
Connection Pitch | 18 mm between phases |
Number of Pitches | 4 (36 mm total width) |
Width | 36 mm |
Height | 85 mm |
Depth | 78.5 mm |
Net Weight | 0.25 kg |
Colour | White (RAL9003) |
Terminals & Connections | |
Connection Type | Single terminal (top or bottom), double tunnel |
Rigid Conductor (copper) | 1…25 mm² |
Flexible Conductor (copper) | 1…16 mm² |
Flexible with Ferrule (copper) | 1…10 mm² |
With Ring Terminal (Cu/Al) | Via accessory |
Wire Stripping Length | 14 mm (top or bottom) |
Tightening Torque | 2 N·m (top or bottom) |
Earth‑leakage Protection | Separate add‑on block required |
Environmental & Protection Ratings | |
Standards Compliance | EN/IEC 60947‑2, EN/IEC 60898‑1 |
IP Degree (terminals) | IP20 (IEC 60529) |
IP in Enclosure | IP40 (Insulation class II) |
Pollution Degree | 3 (EN/IEC 60947‑2) |
Overvoltage Category | IV |
Tropicalisation | 2 (IEC 60068‑1) |
Relative Humidity | 95% at 55°C |
Operating Altitude | 0…2000 m |
Operating Temperature | -35°C … +70°C |
Storage Temperature | -40°C … +85°C |
Sustainability & Compliance | |
Halogen‑free status | Product contains halogen above thresholds (not halogen‑free) |
PVC‑free | Yes |
Silicone‑free | No |
POPs | No POPs |
Recyclability Potential | 54% |
EU RoHS Directive | Compliant |
REACH SVHC | Contains SVHC above threshold |
SCIP Number | 26F71d1‑98cf‑4280‑8725‑455b9a6b2fb9 |
Packaging with recycled cardboard | Yes |
Packaging without single‑use plastic | Yes |
WEEE Label | Required for EU disposal (separate collection) |
Repair / Take‑back | No / No |
Logistics | |
Country of Origin | Not specified (typically Bulgaria for iC60 series) |
Warranty | 18 months |
Package 1 (Single unit) | 1 pc; H 7.5 cm × W 3.7 cm × L 9.5 cm; weight 216 g |
Package 2 (Box of 6) | 6 units; H 8.2 cm × W 10.0 cm × L 22.5 cm; weight 1.356 kg |
Package 3 (Pallet of 66) | 66 units; H 30 cm × W 30 cm × L 40 cm; weight 15.420 kg |
Carbon Footprint (Lifecycle) | |
Total | 16 kg CO₂ eq. |
Manufacturing (A1‑A3) | 2 kg CO₂ eq. |
Distribution (A4) | 0 kg CO₂ eq. |
Installation (A5) | 0 kg CO₂ eq. |
Use Phase (B2, B3, B4, B6) | 14 kg CO₂ eq. |
End‑of‑life (C1‑C4) | 0.6 kg CO₂ eq. |
Environmental Disclosure | Product Environmental Profile available |