  • Schneider

  • A9F74401

  • IN STOCK

  • T/T

  • XIAMEN

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The Schneider Electric Acti9 iC60N A9F74401 is a four-pole miniature circuit breaker designed for low-voltage distribution systems. It is rated 1 A with a C-characteristic thermal-magnetic trip unit, providing dependable protection against short circuits and overloads. The device delivers a short-circuit breaking capacity of 50 kA at 220–240 V AC under EN/IEC 60947-2 and 6,000 A at 400 V AC under EN/IEC 60898-1, satisfying both industrial and residential requirements. It supports isolation and incorporates VisiTrip fault indication plus VisiSafe contact-position verification for safe downstream maintenance. The fast-closing mechanism extends service life to 10,000 electrical and 20,000 mechanical cycles. With a 500 V AC rated insulation voltage and 6 kV impulse withstand, it handles demanding environments. The breaker clips onto a 35 mm DIN rail and occupies eight 9 mm pitches (72 mm width). It measures 85 mm (H) × 72 mm (W) × 78.5 mm (D) and weighs 0.5 kg. Operating temperature ranges from -35 °C to +70 °C, with storage from -40 °C to +85 °C. It offers IP20 terminal protection (IP40 when enclosed), pollution degree 3, overvoltage category IV, RoHS compliance, halogen-free plastic parts, and a 54% recyclability potential.

Parameter

Details

General

Product Model

A9F74401

Range

Acti9

Product Name

Acti9 iC60

Product or Component Type

Miniature circuit-breaker

Device Short Name

iC60N

Device Application

Distribution

Poles Description

4P

Number of Protected Poles

4

[In] Rated Current

1 A

Network Type

DC / AC

Trip Unit Technology

Thermal-magnetic

Curve Code

C

Utilisation Category

Category A conforming to EN/IEC 60947-2

Suitability for Isolation

Yes conforming to EN/IEC 60898-1; Yes conforming to EN/IEC 60947-2

Standards

EN/IEC 60947-2, EN/IEC 60898-1

Breaking Capacity

– EN/IEC 60947-2 (AC)

50 kA at 220…240 V AC 50/60 Hz

– EN/IEC 60898-1 (AC)

6,000 A at 400 V AC 50/60 Hz

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz conforming to EN/IEC 60947-2

Rated Impulse Withstand Voltage (Uimp)

6 kV conforming to EN/IEC 60947-2

Durability & Signalling

Mechanical Durability

20,000 cycles

Electrical Durability

10,000 cycles

Contact Position Indicator

Yes

Control Type

Toggle

Local Signalling

Trip indicator

Mounting & Physical

Mounting Mode

Clip-on; Removable comb busbar installed

Mounting Support

35 mm DIN rail

Comb Busbar and Distribution Block Compatibility

Top or bottom: Yes

Connection Pitch

18 mm between phases

9 mm Pitches

8

Height

85 mm

Width

72 mm

Depth

78.5 mm

Net Weight

0.5 kg

Colour

White

Terminals & Connections

Connection Type

Single terminal (top or bottom)

Rigid Conductor (copper)

1…25 mm²

Flexible Conductor (copper)

1…16 mm²

Flexible with Ferrule (copper)

1…16 mm²

Flexible (copper or aluminium, with ring terminal and accessory)

1.0 cable

Wire Stripping Length

14 mm for top or bottom connection

Tightening Torque

2 N·m top or bottom

Earth-leakage Protection

Separate block

Environmental & Protection Ratings

IP Degree of Protection

IP20 conforming to IEC 60529
IP40 in modular enclosure (Insulation class II) conforming to IEC 60529

Pollution Degree

3 conforming to EN/IEC 60947-2

Overvoltage Category

IV

Tropicalisation

2 conforming to IEC 60068-1

Relative Humidity

95% at 55 °C

Operating Altitude

0…2000 m

Ambient Air Temperature for Operation

-35…70 °C

Ambient Air Temperature for Storage

-40…85 °C

Sustainability & Compliance

Halogen-free (plastic parts)

Halogen free plastic parts product

PVC-free

Yes

Silicone-free

No

PFAS

Item contains PFAS Chemicals

Recyclability Potential

54%

EU RoHS Directive

Compliant

REACH Regulation

Reference contains SVHC above threshold

SCIP Number

26ff71d1-98cf-4280-8725-455b9a6b2fb9

Packaging with Recycled Cardboard

Yes

Packaging without Single-use Plastic

Yes

WEEE Label

Required for EU disposal (separate collection)

Logistics & Packaging

Package 1 (PCE)

1 pc; H 7.5 cm × W 7.2 cm × L 9.5 cm; weight 451.0 g

Package 2 (BB1)

3 units; H 8.0 cm × W 9.8 cm × L 22.5 cm; weight 1.417 kg

Package 3 (S03)

33 units; H 30.0 cm × W 30.0 cm × L 40.0 cm; weight 16.079 kg

Carbon Footprint (Lifecycle)

Total

42 kg CO₂ eq.

Manufacturing (A1-A3)

3 kg CO₂ eq.

Distribution (A4)

0.1 kg CO₂ eq.

Installation (A5)

0 kg CO₂ eq.

Use Phase (B2, B3, B4, B6)

37 kg CO₂ eq.

End-of-life (C1-C4)

1 kg CO₂ eq.

Environmental Disclosure

Product Environmental Profile available

Previous: 
Next: 

Related Products

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.