nyban1
You are here: Home » Systems » Emergency Shutdown System » Electrical Protection and Control » Schneider A9F74170 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 0.5A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Leave Us A Message

loading

Schneider A9F74170 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 0.5A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)

  • Schneider

  • A9F74170

  • IN STOCK

  • T/T

  • XIAMEN

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The A9F74170 is an ultra‑low‑current, single‑pole miniature circuit breaker from Schneider Electric’s Acti9 iC60N series, featuring a C‑curve tripping characteristic (magnetic trip at 8 × In). With a rated current of just 0.5 A, this MCB is specifically tailored for the most sensitive circuits – including control transformers, signal lines, electronic power supplies, and instrumentation – where even minor overcurrents can damage delicate components and where traditional higher‑rated breakers offer inadequate protection. The C‑curve strikes a fine balance between immunity to harmless transient surges and rapid response to genuine faults, ensuring nuisance‑free operation in low‑power applications. Despite its minimal rating, this breaker delivers an outstanding ultimate breaking capacity of 50 kA at 220‑240 V AC under the industrial EN/IEC 60947‑2 standard, and 6 kA at 230 V AC per the residential EN/IEC 60898‑1 norm – guaranteeing reliable fault interruption even in high‑fault‑current scenarios. It is certified to both standards, making it suitable for industrial automation panels, commercial control cabinets, and specialised residential metering systems. The device incorporates the proven VisiTrip fault indicator, which instantly highlights the tripped pole for rapid diagnosis, and the VisiSafe green strip that offers positive visual confirmation of contact opening – a vital safety check for maintenance. Its quick‑make/quick‑break mechanism, independent of the toggle handle, ensures consistent performance over 10,000 electrical and 20,000 mechanical cycles. With a compact 18 mm width (2 modules) and DIN‑rail mounting, it optimises panel space. The double‑tunnel terminals accept conductors up to 25 mm² (rigid) and 16 mm² (flexible) with a 2 N·m torque, and the breaker offers IP20 terminal protection and IP40 when enclosed, operating from -35 °C to +70 °C. Built with halogen‑free plastics and PVC‑free materials, it achieves 54% recyclability and a total lifecycle carbon footprint of 14 kg CO₂ eq., reflecting Schneider Electric’s eco‑design approach. The model carries NF quality label and is fully compatible with the Acti 9 range of RCDs and busbars.

Parameter

Details

General

Product Model

A9F74170

Range

Acti9

Product Name

Acti9 iC60

Device Short Name

iC60N

Device Application

Distribution

Poles Description

1P

Number of Protected Poles

1

Rated Current (In)

0.5 A

Network Type

AC / DC

Trip Unit Technology

Thermal‑magnetic

Tripping Curve

C

Magnetic Tripping Limit

8 x In ± 20%

Suitability for Isolation

Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2)

Utilisation Category

Category A (EN/IEC 60947‑2)

Quality Labels

NF

Breaking Capacity (Icu)

– EN/IEC 60947‑2 (AC)

50 kA at 12…60 V AC 50/60 Hz
50 kA at 100…133 V AC 50/60 Hz
50 kA at 220…240 V AC 50/60 Hz

– EN/IEC 60947‑2 (DC)

15 kA at 12…60 V DC
10 kA at 60…72 V DC

– EN/IEC 60898‑1 (AC)

6,000 A at 230 V AC 50/60 Hz

Service Breaking Capacity (Ics)

– EN/IEC 60947‑2 (AC)

50 kA (100%) at 12…60 V AC
50 kA (100%) at 100…133 V AC
50 kA (100%) at 220…240 V AC

– EN/IEC 60947‑2 (DC)

15 kA (100%) at 12…60 V DC
10 kA (100%) at 60…72 V DC

Limitation Class

Class 3 (EN/IEC 60898‑1)

Rated Operational Voltage (Ue)

12…60 V AC 50/60 Hz
100…133 V AC 50/60 Hz
220…240 V AC 50/60 Hz
12…60 V DC
60…72 V DC

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz (EN/IEC 60947‑2)

Rated Impulse Withstand Voltage (Uimp)

6 kV (EN/IEC 60947‑2)

Network Frequency

50/60 Hz

Durability

Mechanical Durability

20,000 cycles

Electrical Durability

10,000 cycles

Contact Position Indicator

Yes (toggle)

Local Signalling

Trip indicator (VisiTrip)

Mounting & Physical

Mounting Mode

Clip‑on (35 mm DIN rail)

Removable Comb Busbar

Installed; compatible top or bottom

Connection Pitch

18 mm between devices

Number of Pitches

2 (18 mm total width)

Width

18 mm

Height

85 mm

Depth

78.5 mm

Net Weight

0.215 kg

Colour

White (RAL9003)

Terminals & Connections

Connection Type

Single terminal (top or bottom), double tunnel

Rigid Conductor (copper)

1…25 mm²

Flexible Conductor (copper)

1…16 mm²

Flexible with Ferrule (copper)

1…10 mm²

With Ring Terminal (Cu/Al)

Via accessory

Wire Stripping Length

14 mm (top or bottom)

Tightening Torque

2 N·m (top or bottom)

Earth‑leakage Protection

Without (separate add‑on block required)

Environmental & Protection Ratings

Standards Compliance

EN/IEC 60947‑2, EN/IEC 60898‑1

IP Degree (terminals)

IP20 (IEC 60529)

IP in Enclosure

IP40 (Insulation class II)

Pollution Degree

3 (EN/IEC 60947‑2)

Overvoltage Category

IV

Tropicalisation

2 (IEC 60068‑1)

Relative Humidity

95% at 55°C

Operating Altitude

0…2000 m

Operating Temperature

-35°C … +70°C

Storage Temperature

-40°C … +85°C

Sustainability & Compliance

Halogen‑free (plastic parts)

Yes

PVC‑free

Yes

Silicone‑free

No

Recyclability Potential

54%

EU RoHS Directive

Compliant

REACH SVHC

Contains SVHC above threshold

SCIP Number

26F71d1‑98cf‑4280‑8725‑455b9a6b2fb9

Packaging with recycled cardboard

Yes

Packaging without single‑use plastic

Yes

WEEE Label

Required for EU disposal (separate collection)

Repair / Take‑back

No / No

Logistics

Country of Origin

Not specified (typically Bulgaria for iC60 series)

Warranty

18 months

Package 1 (Single unit)

1 pc; H 2.0 cm × W 7.5 cm × L 9.5 cm; weight 112 g

Package 2 (Box of 12)

12 units; H 8.0 cm × W 10.0 cm × L 22.5 cm; weight 1.421 kg

Package 3 (Pallet of 132)

H 30 cm × W 30 cm × L 40 cm; weight 16.011 kg

Carbon Footprint (Lifecycle)

Total

14 kg CO₂ eq.

Manufacturing (A1‑A3)

0.8 kg CO₂ eq.

Distribution (A4)

0 kg CO₂ eq.

Installation (A5)

0 kg CO₂ eq.

Use Phase (B2, B3, B4, B6)

12 kg CO₂ eq.

End‑of‑life (C1‑C4)

0.3 kg CO₂ eq.

Environmental Disclosure

Product Environmental Profile available


Previous: 
Next: 

Related Products

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.