  • Schneider

  • A9F75320

  • IN STOCK

  • T/T

  • XIAMEN

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The A9F75320 is a three-pole miniature circuit breaker from Schneider Electric’s Acti9 iC60N range, designed to provide dependable overcurrent protection in three-phase AC and DC distribution systems. Rated at 20 A with a D‑curve trip response, it is particularly suited to loads with high inrush currents, such as small motors, transformers, solenoid valves, and capacitive equipment, where lower‑curve devices may trip unnecessarily. The breaker offers a short‑circuit breaking capacity of 20 kA at 220–240 V AC under EN/IEC 60947‑2 and 6 kA at 400 V AC under EN/IEC 60898‑1, and it is certified to both industrial and residential standards. Its VisiTrip indicator quickly identifies the faulted pole to reduce maintenance time, while the VisiSafe green strip confirms physical contact opening for safe downstream work. A fast‑closing mechanism, independent of the toggle, helps extend service life, with 10,000 electrical and 20,000 mechanical cycles. The unit occupies six 9 mm pitches (54 mm width) and mounts on DIN rail, with IP20 terminal protection (IP40 when enclosed). It operates from -35 °C to +70 °C and is finished in white (RAL9003). Weighing 0.375 kg, it is a compact, robust solution for commercial and industrial three‑phase boards.

Parameter

Details

General

Product Model

A9F75320

Range

Acti9

Product Name

Acti9 iC60

Device Short Name

iC60N

Device Application

Distribution

Poles Description

3P

Number of Protected Poles

3

Rated Current (In)

20 A

Network Type

AC / DC

Trip Unit Technology

Thermal‑magnetic

Tripping Curve

D

Magnetic Tripping Limit

12 x In ± 20% (typical for D curve)

Suitability for Isolation

Yes (conforming to EN/IEC 60898‑1 and EN/IEC 60947‑2)

Utilisation Category

Category A (EN/IEC 60947‑2)

Breaking Capacity (Icu)

– EN/IEC 60947‑2 (AC)

20 kA at 220…240 V AC 50/60 Hz (per screenshot); other voltages per series datasheet

– EN/IEC 60898‑1 (AC)

6,000 A at 400 V AC 50/60 Hz

Service Breaking Capacity (Ics)

Not specified in screenshot; refer to product datasheet

Limitation Class

Class 3 (EN/IEC 60898‑1)

Rated Operational Voltage (Ue)

220…240 V AC 50/60 Hz (per screenshot); series also supports 12…133 V AC, 380…415 V AC, 440 V AC, and ≤180 V DC

Rated Insulation Voltage (Ui)

500 V AC 50/60 Hz (EN/IEC 60947‑2)

Rated Impulse Withstand Voltage (Uimp)

6 kV (EN/IEC 60947‑2)

Network Frequency

50/60 Hz

Durability

Mechanical Durability

20,000 cycles

Electrical Durability

10,000 cycles

Contact Position Indicator

Yes (toggle)

Control Type

Toggle

Local Signalling

Trip indicator (VisiTrip)

Padlocking Provision

Not specified in screenshot; likely padlockable

Mounting & Physical

Mounting Mode

Clip‑on (35 mm DIN rail)

Removable Comb Busbar

Installed; compatible top or bottom

Connection Pitch

18 mm between phases

Number of Pitches

6 (54 mm total width)

Width

54 mm

Height

85 mm

Depth

78.5 mm

Net Weight

0.375 kg

Colour

White (RAL9003)

Terminals & Connections

Connection Type

Single terminal (top or bottom), double tunnel

Rigid Conductor (copper)

1…25 mm² (typical for series)

Flexible Conductor (copper)

1…16 mm² (typical for series)

Wire Stripping Length

14 mm (top or bottom)

Tightening Torque

2 N·m (top or bottom)

Earth‑leakage Protection

Separate add‑on block (Vigi iC60) required

Environmental & Protection Ratings

Standards Compliance

EN/IEC 60947‑2, EN/IEC 60898‑1

IP Degree (terminals)

IP20 (IEC 60529)

IP in Enclosure

IP40 (Insulation class II)

Pollution Degree

3 (EN/IEC 60947‑2)

Overvoltage Category

IV

Tropicalisation

2 (IEC 60068‑1)

Relative Humidity

95% at 55°C

Operating Altitude

0…2000 m (typical for series)

Operating Temperature

-35°C … +70°C

Storage Temperature

-40°C … +85°C

Sustainability & Compliance

Halogen‑free status

Not specified in screenshot; refer to datasheet

PVC‑free

Not specified in screenshot; refer to datasheet

Recyclability Potential

Not specified in screenshot; refer to datasheet

EU RoHS Directive

Not specified in screenshot; refer to datasheet

REACH SVHC

Not specified in screenshot; refer to datasheet

WEEE Label

Required for EU disposal (separate collection) – typical for series

Previous: 
Next: 

Related Products

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.