nyban1
You are here: Home » Systems » Sensing System » Bently Nevada Additional Sensing Devices » Bently Nevada 330500-00-01 Velomitor Piezo-velocity Sensor
Leave Us A Message

loading

Bently Nevada 330500-00-01 Velomitor Piezo-velocity Sensor

  • Bently Nevada

  • 330500-00-01

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The Bently Nevada 330500-00-01 is a specific configuration of the industry‑proven 330500 Velomitor Piezo‑velocity Sensor, engineered for critical machinery monitoring applications that require CSA (Canadian Standards Association) certification for use in hazardous locations, while offering maximum flexibility in mounting by excluding a factory‑supplied thread adapter. This variant features no mounting adapter (suffix -00), leaving the sensor’s native 3/8‑24 UNF‑2B body thread exposed, and carries CSA approval (suffix -01), making it suitable for installation in North American hazardous (classified) areas where intrinsic safety is required. It is the ideal choice for users who have existing mounting holes matching the 3/8‑24 thread, who prefer to use custom adapters, or who want to avoid the cost of a pre‑installed adapter while still meeting CSA safety standards.

The 330500 series is a state‑of‑the‑art piezoelectric velocity sensor with embedded integrated electronics, designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration on rotating machinery. Unlike traditional velocity transducers that rely on moving coils and mechanical springs, the 330500 employs a solid‑state design with no moving parts, offering superior reliability, extended service life, and the ability to be mounted in any orientation—vertically, horizontally, or at any angle—without performance degradation.

The 330500-00-01 provides a velocity output of 100 mV/in/s (3.94 mV/mm/s) with a frequency response from 4.5 Hz to 5 kHz (±3 dB) and a velocity range of 50 in/s peak (1270 mm/s) . Its robust construction includes a hermetically sealed 316L stainless steel case, a 2‑pin MIL‑C‑5015 connector, and a wide operating temperature range from -55°C to +121°C. The sensor is case‑isolated to prevent ground loops, and it offers excellent immunity to magnetic fields and base strain. The -00-01 variant is supplied without a mounting adapter, but carries CSA certification for Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; and Class III hazardous locations, with entity parameters that enable intrinsic safety operation.

This introduction focuses exclusively on the 330500-00-01 configuration, highlighting its unique combination of CSA certification and adapter‑free mounting flexibility, comparing it with other adapter options (e.g., 330500-01-01 with 1/2‑20 UNF adapter) and with non‑certified versions (e.g., 330500-00-00) to guide proper selection for hazardous‑area applications where custom or existing mounting solutions are preferred.

Functional Description and CSA Certification Significance

The 330500-00-01 accelerometer operates on the piezoelectric principle, where a piezoelectric crystal generates an electrical charge proportional to the acceleration of the sensor housing. An internal charge amplifier and integrator circuit convert this acceleration signal into a velocity signal, which is then output as a low‑impedance voltage. The output bias voltage is nominally -12 V dc (referenced to Pin A), which allows the sensor to be powered by the same two‑wire interface used for many industrial monitoring systems. The sensor requires a power supply of -24 V dc (nominal) and draws a bias current of 2 mA (typical), with the dynamic signal superimposed on the bias voltage.

The integration of the electronics within the sensor housing eliminates the need for external signal conditioning, simplifies installation, and reduces the risk of noise pickup. The solid‑state design ensures that there are no moving parts to wear out, providing long‑term stability and repeatability. The 330500-00-01 is designed to be mounted directly on the machine casing or bearing housing using the body thread. The standard sensor body incorporates a 3/8‑24 UNF‑2B mounting hole, which is a common thread size for many industrial mounting bases and adapters. By choosing the -00 adapter option, the user receives the sensor without a pre‑installed adapter, offering maximum flexibility to select a third‑party adapter or to mount the sensor directly into a threaded hole that matches the body thread.

The -01 certification adds CSA approval for use in hazardous locations. The sensor carries the following CSA markings (as per the datasheet):

  • Class I, Division 1, Groups A, B, C, D (gas/vapor atmospheres)

  • Class II, Groups E, F, G (combustible dusts)

  • Class III (fibers/flyings)

  • Temperature class T3, with ambient temperature range -55°C ≤ Tamb ≤ 121°C.

Additionally, the sensor meets the entity parameters for intrinsic safety (when connected through an approved barrier): Ui = 28 V, Ii = 100 mA, Pi = 0.84 W, Ci = 10.8 nF, Li = 0 μH. These parameters are identical to the ATEX‑certified versions but are recognized under CSA standards for North American installations.

The CSA certification is critical for compliance with the Canadian Electrical Code and for installations in the United States where CSA is accepted (NRTL). By choosing the -01 option, users can deploy the 330500 in hazardous areas without the need for additional certification, ensuring safety and regulatory compliance.

The sensor’s frequency response covers the range from 4.5 Hz to 5 kHz (270 cpm to 300,000 cpm) within ±3 dB, and from 6.0 Hz to 2.5 kHz (360 cpm to 150,000 cpm) within ±0.9 dB. This wide bandwidth makes it suitable for both low‑speed and high‑speed machinery, including gearboxes and turbines with high blade‑pass frequencies. The velocity output is particularly advantageous for machinery protection because it provides a direct measure of vibration severity, which is often the parameter used in international standards (e.g., ISO 10816) for evaluating machine health.

The sensor's amplitude linearity is ±2% up to 6 in/s peak, and its transverse sensitivity is less than 5% of the axial sensitivity. The mounted resonant frequency exceeds 12 kHz, ensuring that the sensor's natural resonance does not interfere with the measurement band. The case‑isolated design prevents ground loops, and the hermetically sealed construction protects the electronics from moisture and contaminants.

Detailed Comparison with Other 330500 Configurations – Adapter and Approval Options

To assist in proper sensor selection, the following table compares the 330500-00-01 with other common configurations: the 330500-00-00 (no adapter, no approvals), the 330500-01-01 (1/2‑20 UNF adapter, CSA), the 330500-00-02 (no adapter, ATEX), and the 330500-01-04 (1/2‑20 UNF adapter, multiple approvals). This comparison highlights the unique value of the -00-01 for flexible, CSA‑certified installations.

Selection Guide – Key Differences

Feature / Option

330500-00-01

330500-00-00

330500-01-01

330500-00-02

330500-01-04

Mounting Adapter

None (body thread 3/8‑24 UNF‑2B)

None

1/2‑20 UNF

None

1/2‑20 UNF

Agency Approvals

CSA (US/Canada)

None

CSA

ATEX (European)

Multiple (CSA, ATEX)

Hazardous Area Suitability

Yes (Class I Div 1, Class II, Class III)

No

Yes

Yes (Zone 0/1/2)

Yes

Entity Parameters

Ui=28V, Ii=100mA, Pi=0.84W, Ci=10.8nF, Li=0µH

N/A

Same

Same

Same

Sensitivity

100 mV/in/s

Same

Same

Same

Same

Frequency Response

4.5 Hz – 5 kHz (±3 dB)

Same

Same

Same

Same

Velocity Range

50 in/s peak

Same

Same

Same

Same

Output Bias Voltage

-12 V dc ±3 V

Same

Same

Same

Same

Connector

2‑pin MIL‑C‑5015

Same

Same

Same

Same

Case Material

316L stainless steel

Same

Same

Same

Same

Temperature Range

-55°C to +121°C

Same

Same

Same

Same

Base Strain Sensitivity

0.005 in/s/mstrain

Same

Same

Same

Same

Typical Application

Flexible mounting in North American hazardous areas with custom adapters or direct 3/8‑24 mounting

Flexible mounting in safe areas

Hazardous areas with 1/2‑20 mounting

Hazardous areas requiring ATEX with flexible mounting

Hazardous areas requiring 1/2‑20 and multiple approvals

Certifications

CSA, FCC, EMC, RoHS, ABS

FCC, EMC, RoHS, ABS

CSA, FCC, EMC, RoHS, ABS

ATEX, FCC, EMC, RoHS, ABS

CSA, ATEX, FCC, EMC, RoHS, ABS

Ordering Part Number

330500-00-01

330500-00-00

330500-01-01

330500-00-02

330500-01-04

The 330500-00-01 is the most flexible CSA‑certified configuration in the 330500 series. Choose this variant when:

  • You need CSA certification for hazardous locations in North America.

  • You have an existing mounting hole that matches the 3/8‑24 UNF‑2B thread, or you plan to use a custom adapter not offered by Bently Nevada.

  • You want to minimize cost by omitting the adapter while still meeting safety requirements.

  • You prefer the body thread for direct mounting without an extra adapter.

If you need a specific adapter (e.g., 1/2‑20 UNF for quick‑connect mounts) with CSA, choose 330500-01-01. If you require ATEX certification instead of CSA, choose 330500-00-02. For multiple approvals, choose 330500-01-04.

Hardware Characteristics – Specific to 330500-00-01

Physical Dimensions and Mounting

  • Body Thread (exposed): 3/8‑24 UNF‑2B, with a minimum threaded depth of 6.4 mm (0.250 in) and a maximum drill depth of 14.0 mm (0.550 in). The sensor body includes a 15/16 inch hexagonal feature for tightening.

  • Diameter: 25.3 mm (0.995 in)

  • Height: 63.2 mm (2.49 in) (without adapter; with an adapter, the height increases)

  • Weight: 142 grams (5.0 oz) typical (without adapter)

  • Case Material: 316L stainless steel, hermetically sealed

  • Connector: 2‑pin MIL‑C‑5015 hermetically sealed receptacle, 316L stainless steel shell

  • Mounting Torque: 32‑46 kg·cm (24‑40 in‑lb) maximum (for the sensor body when tightened into a mounting hole)

Polarity and Wiring

The sensor has a 2‑pin connector. The pin assignment is:

  • Pin A: Signal + (positive output when the sensor case moves toward the connector)

  • Pin B: Common (return) and power supply negative (shield)

The output bias voltage is -12 V dc (±3 V) referenced to Pin A. The sensor requires a -24 V dc supply (nominal) with a bias current of 2 mA (typical). The dynamic signal is a velocity output superimposed on the bias voltage.

Cables and Maximum Length

The 330500-00-01 is compatible with the same two‑conductor shielded cables as all 330500 variants. For hazardous area installations, the cable must be suitable for intrinsic safety and must meet the entity parameter limits. The recommended cable (part number 02173006) is 18 AWG twisted shielded bulk cable. For pre‑terminated cables, the following options are available (custom lengths in 1.0 ft increments):

Cable Part Number

Description

Min/Max Length

9571-NN

22 AWG twisted shielded with 2‑socket female connector and terminal lugs

2.0 – 99 ft

84661-NN

22 AWG armored cable with 2‑socket connector and terminal lugs

3.0 – 96 ft

89477-NN

18 AWG right‑angle 2‑socket plug and terminal lugs (compatible with 21128 housing)

2.0 – 99 ft

125065-NN

18 AWG with fluorosilicone elastomer boot, 2‑socket plug, terminal lugs

2.0 – 99 ft

Maximum cable length: 305 meters (1,000 ft) of cable (part number 02173006) with no signal degradation, provided the cable capacitance is within limits. For longer lengths, contact Bently Nevada Tech Support. The recommended cable length for a 50 g vibration at 10 kHz and cable capacitance of 200 pF/m is 208 ft (63 m). In hazardous areas, cable capacitance and inductance must be added to the sensor's Ci and Li, and the total must not exceed the barrier's limits.

Environmental and Electrical Specifications

  • Power Requirements: -24 V dc nominal, 2 mA bias current typical

  • Output Bias Voltage: -12 V dc ±3 V

  • Dynamic Output Impedance: < 2400 Ω

  • Operating Temperature: -55°C to +121°C (-67°F to +250°F)

  • Shock Survivability: 5,000 g peak maximum

  • Relative Humidity: 100% condensing (non‑submerged); case is hermetically sealed

  • Base Strain Sensitivity: 0.005 in/s/mstrain (very low, minimising errors from mounting surface flexure)

  • Magnetic Field Susceptibility: < 51 in/s/gauss at 50 gauss, 50‑60 Hz

  • Grounding: Case isolated (housing isolated from signal common)

CSA Hazardous Area Compliance – Detailed for 330500-00-01

The 330500-00-01 is certified to the following CSA standards (as per the datasheet):

  • Class I, Division 1, Groups A, B, C, D – For flammable gases or vapors in normal operating conditions.

  • Class II, Groups E, F, G – For combustible dusts.

  • Class III – For ignitable fibers or flyings.

  • Temperature class T3 (maximum surface temperature 200°C under fault conditions), with ambient temperature range -55°C ≤ Tamb ≤ +121°C.

  • The sensor must be installed per drawing 167537.

Entity Parameters (for intrinsic safety):

Parameter

Value

Ui (maximum input voltage)

28 V

Ii (maximum input current)

100 mA

Pi (maximum input power)

0.84 W

Ci (internal capacitance)

10.8 nF

Li (internal inductance)

0 μH

Conditions of Safe Use (per CSA):

  • The sensor must be connected to an associated intrinsically safe apparatus that meets the entity parameters.

  • The interconnecting cable must have capacitance and inductance such that the total (sensor + cable) does not exceed the barrier’s limits.

  • Installation must comply with the Canadian Electrical Code (C22.1) and/or National Electrical Code (NFPA 70).

Installation Best Practices for 330500-00-01 in CSA‑Certified Installations

  1. Intrinsic Safety Barrier – Always connect the sensor through a CSA‑certified intrinsic safety barrier that limits voltage, current, and power to within the entity parameters. Ensure the barrier’s output parameters (Uo, Io, Po) do not exceed Ui, Ii, and Pi.

  2. Cable Selection and Length Calculation – The sensor’s Ci (10.8 nF) and Li (0 μH) must be added to the cable’s capacitance and inductance. The total must not exceed the barrier’s allowable cable parameters. For long runs, use lower‑capacitance cables (e.g., 18 AWG) to maximize allowable length. Consult the barrier manufacturer’s documentation for cable length calculations.

  3. Mounting Surface Preparation – Clean the mounting surface to remove paint, rust, or debris. Achieve a surface finish of 32 µin rms or better. Ensure the threaded hole matches the 3/8‑24 UNF‑2B thread and is perpendicular to the measurement axis. Apply anti‑seize compound if required, and torque the sensor body to 32‑46 kg·cm (24‑40 in‑lb). Do not use the connector body to apply torque; use a wrench on the 15/16 inch hex flats.

  4. Cable Connection – Align the 2‑pin connector (Pin A and Pin B) and tighten the coupling nut securely. In hazardous areas, ensure the connector is properly mated and sealed (IP54 or better) to prevent ingress.

  5. Grounding – The case is isolated, so grounding is not required for the sensor body. However, the cable shield should be grounded at the power supply end (typically at the barrier) to minimize noise. Do not ground the shield at both ends to avoid ground loops.

  6. Environmental Protection – Although the sensor is IP68, the cable termination and connectors require additional protection (splash boots, conduit, etc.) for outdoor or wet locations.

Comparison with Other CSA‑Certified Options – Why Choose 330500-00-01?

  • vs. 330500-01-01 (with 1/2‑20 UNF adapter) – The -01-01 includes a 1/2‑20 UNF adapter, which is convenient for quick‑connect mounts (e.g., 46122-01). If you do not need this specific adapter, the -00-01 saves cost and provides the flexibility to use any adapter you choose, or to mount directly into a 3/8‑24 hole.

  • vs. 330500-00-00 (no approvals) – The -00-00 lacks CSA certification. For any North American hazardous area installation, the -01 (CSA) version is mandatory. The -00-01 provides the same mounting flexibility but adds critical safety compliance.

  • vs. 330500-00-02 (ATEX) – The -02 offers ATEX certification for Europe. If your installation is in North America and requires CSA, choose -01. If you need both, consider -04 (multiple approvals).

  • vs. 330500-01-04 (multiple approvals with adapter) – The -04 includes both CSA and ATEX, plus a 1/2‑20 adapter. If you don’t need the adapter or only need CSA, the -00-01 is more economical.

Ordering Information

When ordering the 330500-00-01, use the full part number exactly as shown:

  • 330500 – Base model (Velomitor Piezo‑velocity Sensor)

  • -00 – Mounting Thread Adapter: None (body thread 3/8‑24 UNF‑2B exposed)

  • -01 – Agency Approval: CSA (US/Canada)

Compatible Cables and Accessories for Hazardous Areas

Part Number

Description

02173006

Bulk cable (2 conductor 18 AWG twisted shielded) – specify length in feet

9571-NN

22 AWG cable with 2‑socket connector and terminal lugs (for non‑hazardous areas; for hazardous areas, ensure barrier compatibility)

84661-NN

22 AWG armored cable

89477-NN

18 AWG right‑angle cable (compatible with 21128 housing)

125065-NN

18 AWG cable with fluorosilicone elastomer boot

100076

User Guide

89409-01

1/2‑20 UNF mounting adapter (spare)

89410-01

M8 x 1 mounting adapter

89411-01

1/4‑28 UNF mounting adapter

89412-01

1/4‑20 UNC mounting adapter

89413-01

1/4‑18 NPT mounting adapter (spares only)

46000-01

Magnetic Base (for temporary use, non‑hazardous)

46122-01

Quick Connect (for semi‑permanent mounting, uses 1/2‑20 adapter)

Note: The 330500-00-01 does not include a cable or adapter; order separately. Ensure cables and barriers are CSA‑certified for hazardous area use.

Certifications and Compliance – Special Note

The 330500-00-01 carries CSA certification for North American hazardous locations. It also complies with FCC Part 15, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU, China RoHS (EFUP 15 years), and ABS Marine. It is NOT certified to ATEX or IECEx; for those, select -02 or -04 options.

Warranty and Support

The Bently Nevada 330500-00-01 is covered under the standard manufacturer’s warranty. For technical support, application assistance, or help with CSA certification documentation, contact your local Bently Nevada representative or access the Bently Nevada Media Library at bntechsupport.com.

Specification Category

Details

Part Number

330500-00-01

Product Type

Velomitor Piezo‑velocity Sensor

Mounting Adapter

None (body thread 3/8‑24 UNF‑2B exposed)

Agency Approval Option

CSA (US/Canada) – Class I Div 1, Class II, Class III

Hazardous Area Certifications

CSA: Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III; T3; -55°C ≤ Tamb ≤ +121°C

Entity Parameters

Ui=28 V, Ii=100 mA, Pi=0.84 W, Ci=10.8 nF, Li=0 μH

Sensitivity

3.94 mV/mm/s (100 mV/in/s) ±5%

Frequency Response

4.5 Hz – 5 kHz (270 – 300,000 cpm) ±3.0 dB; 6.0 Hz – 2.5 kHz (360 – 150,000 cpm) ±0.9 dB

Velocity Range

1270 mm/s (50 in/s) peak

Amplitude Linearity

±2% to 152 mm/s (6 in/s) peak

Transverse Sensitivity

< 5% of axial sensitivity

Mounted Resonant Frequency

> 12 kHz

Output Bias Voltage

-12 V dc ±3 V (referenced to Pin A)

Dynamic Output Impedance

< 2400 Ω

Broadband Noise Floor

0.004 mm/s (160 μin/s) rms nominal (4.5 Hz – 5 kHz)

Temperature Sensitivity

-14% to +7.5% typical over operating temperature range

Power Supply Voltage

-24 V dc nominal

Bias Current

2 mA typical

Grounding

Case isolated

Maximum Cable Length

305 m (1,000 ft) with recommended cable (02173006); derate for hazardous area

Operating Temperature

-55°C to +121°C (-67°F to +250°F)

Shock Survivability

5,000 g peak

Relative Humidity

100% condensing (hermetically sealed)

Base Strain Sensitivity

0.005 in/s/mstrain

Magnetic Field Susceptibility

< 51 in/s/gauss (50 gauss, 50‑60 Hz)

Case Material

316L stainless steel

Connector

2‑pin MIL‑C‑5015 hermetically sealed, 316L stainless steel shell

Weight (no adapter)

142 g (5.0 oz) typical

Diameter

25.3 mm (0.995 in)

Height (no adapter)

63.2 mm (2.49 in)

Body Mounting Thread

3/8‑24 UNF‑2B

Mounting Torque

32‑46 kg·cm (24‑40 in‑lb) max

Polarity

Pin A positive when case moves toward connector

Maximum Use Altitude

2000 m (typical for industrial sensors)

IP Rating

Equivalent to IP68 (hermetically sealed case, dust‑tight and watertight for sensor only)

Compliance

CSA, FCC Part 15, EMC 2014/30/EU, RoHS 2011/65/EU, China RoHS (EFUP 15 years), ABS Marine Vessels

Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.