nunin 1
Kuna nan: Gida » Tsarukan aiki » Kulawar Turbine » Mark VIe Control System GE DS200DACAG1A Ac-Dc Module Canjin Wuta
Ka Bar Mu Sako

Module Canjin Wuta na GE DS200DACAG1A AC-Dc

  • GE

  • Saukewa: DS200DACAG1A

  • $1500

  • A Stock

  • T/T

  • Xiamen

samuwa:
Yawan:
facebook button sharing
twitter sharing button
maɓallin raba layi
wechat sharing button
linkin sharing button
maballin rabawa pinterest
whatsapp sharing button
kakao sharing button
maballin raba snapchat
button sharing telegram
share wannan button sharing

DS200DACAG1A Module Canjin Wuta ne na AC-Dc wanda General Electric (GE) Energy ya tsara don tsarin sarrafa Mark Ve. Kasancewa da jerin DACA (Ac-Dc Power Conversion Module), wannan ƙirar shine ainihin ɓangaren tsarin Mark VIe Modular Power Distribution (PDM), wanda ake amfani dashi don canza ikon shigar da AC zuwa ƙarfin fitarwa na DC, yana ba da ingantaccen ƙarfin aiki don kayan aikin tsarin sarrafawa mai mahimmanci.


Babban aikin DS200DACAG1A module shine canza ikon shigar da AC 115 V ko 230 V zuwa ikon fitarwa na 125 V DC. Lokacin da tushen wutar lantarki na farko na tsarin shine 125 V DC (tare da ko ba tare da baturi ba), tsarin DACA yana aiki azaman naúrar juyawa AC-DC, yana samar da ƙarin tushen wutar lantarki ga tsarin. Bugu da ƙari, ƙirar ta ƙunshi ajiyar makamashi na gida wanda ke tsawaita lokacin tafiya a yayin da aka sami cikakkiyar asarar ikon sarrafawa zuwa tsarin sarrafawa na Mark VIe, tabbatar da cewa ana kiyaye ayyukan sarrafawa masu mahimmanci.


An tsara tsarin DS200DACAG1A don biyan buƙatun tsarin sarrafa masana'antu kuma yana fasalta halaye masu zuwa:

  • Zaɓin Input Voltage Mai Sauƙi: Yana goyan bayan shigarwar 115 V ko 230V AC, zaɓaɓɓu ta hanyar igiyoyi na ciki.

  • Stable DC Output: Yana ba da 125 V DC fitarwa, saduwa da Mark VIe tsarin ikon ingancin bukatun.

  • Ma'ajiyar Makamashi Na Cikin Gida: Ƙaƙƙarfan ma'ajin makamashi mai ƙarfi don samar da iyawa ta hanyar tafiya yayin katsewar wutar lantarki.

  • Zane maras Fantsaki: Yana amfani da sanyaya sanyi ba tare da sassa masu motsi ba, yana haɓaka dogaro.

  • Karamin Tsarin Modular: Yana hawa akan bene na majalisar ministoci tare da maƙallan sadaukarwa, ajiyar sarari.

  • Haɗin toshe-da-Play: Mai haɗin JZ mai matsayi 12 guda ɗaya don shigarwar wuta da fitarwa.


Ana amfani da wannan samfurin sosai a cikin tsarin rarraba wutar lantarki na Mark VIe, musamman a aikace-aikacen masana'antu inda ake buƙatar canza wutar AC zuwa DC don samar da tsarin sarrafawa.

II. Maɓallin Ayyuka

1. Canjin wutar AC-DC

Babban aikin DS200DACAG1A module shine canza ƙarfin shigarwar 115 V ko 230 V AC zuwa ikon fitarwa na 125 V DC. Tsarin yana amfani da tsari mai sauƙi wanda ya ƙunshi mai gyara gada mai cikakken igiyar ruwa tare da ƙarfin fitarwa, yana ba da ingantaccen ƙarfin fitarwa na DC wanda ya dace da buƙatun ingancin wutar lantarki na tsarin sarrafa Mark VIe.

2. Input Voltage Selection

Tsarin DS200DACAG1A yana goyan bayan jeri na shigarwar AC guda biyu, zaɓaɓɓu ta hanyar igiyoyi na ciki:

  • 115V AC shigarwar: Zaɓi ta hanyar toshe kebul na ciki cikin mahaɗin JTX1.

  • 230V AC shigarwar: Zaɓi ta hanyar toshe kebul na ciki cikin mahaɗin JTX2.

Wannan ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun tsarin ya dace da ma'auni daban-daban na ikon yanki, saduwa da bukatun aikace-aikacen duniya.

3. Ajiye Makamashi na Gida

Tsarin DS200DACAG1A ya haɗa da ginanniyar ajiyar makamashi mai ƙarfi wanda ke ba da ƙarin tafiya ta lokaci a yayin da aka sami cikakkiyar asarar iko. Wannan fasalin yana da mahimmanci don tabbatar da cewa tsarin sarrafawa zai iya kammala ayyukan kariya masu mahimmanci da adana bayanan matsayi yayin katsewar wutar lantarki.

4. Tace Wuta

Tsarin yana haɗa da'irorin tacewa masu dacewa a ciki, yana kawar da buƙatar matattara na waje. Ana samar da tace wutar shigarwa ta tsarin rarraba wutar lantarki ta AC, tabbatar da cewa ƙarfin da tsarin DACA ya karɓa ya dace da buƙatun inganci.

5. Modular hawa

An ƙera ƙirar DS200DACAG1A don shigarwa na zamani, an amintar da shi zuwa bene na majalisar ministoci tare da maƙallan hawa huɗu. Wannan hanyar hawa yana sauƙaƙa shigarwa akan rukunin yanar gizon yayin tabbatar da kwanciyar hankali da aminci.

III. Hardware Architecture

1. Tsarin Module

Tsarin DS200DACAG1A yana da ƙaƙƙarfan shinge na ƙarfe kuma ya haɗa da:

  • Cikakkun Gadar Gyaran Wuta: Yana canza shigarwar AC zuwa fitarwar DC.

  • Output Capacitor Array: Yana ba da sassaucin wutar lantarki da ajiyar makamashi.

  • Masu Haɗin Zaɓin Wutar Lantarki na shigarwa: JTX1 (115 V) da JTX2 (230V).

  • 12-Position Power Connector JZ: Don shigar da AC da haɗin fitarwa na DC.

2. Hanyar hawa

Modulin DS200DACAG1A an amintar dashi zuwa bene na majalisar ministoci ta amfani da madaidaicin hawa huɗu. Lokacin shigarwa, tabbatar da ingantaccen ƙasa da haɗin kai daidai zuwa mai haɗin JZ2 ko JZ3 na JPDF a cikin tsarin PDM.

3. Bayanin Connector

Nau'in Haɗi Aiki Bayanin
JZ 12-matsayi plug-in Haɗa zuwa JZ2/JZ3 na JPDF module don shigar da AC da fitarwa na DC
Farashin JTX1 Mai haɗin kebul na ciki Yana zaɓar shigarwar 115 V AC
Farashin JTX2 Mai haɗin kebul na ciki Yana zaɓar shigarwar 230V AC

4. Ka'idar Aiki

Tsarin DS200DACAG1A yana karɓar ikon AC daga tsarin rarraba wutar lantarki na AC (JPDB). Mai gyara gada mai cike da igiyar ruwa yana canza AC zuwa DC mai jujjuyawa, wanda sai a santsi da karfin fitarwa don samar da ingantaccen fitarwa na 125V DC. Fitowar DC tana komawa ga tsarin JPDF, inda ya haɗu da ƙarfin baturi don samar da ingantaccen tushen 125 V DC don tsarin sarrafawa.

IV. Cikakken Bayanin Interface

1. JZ Connector

Mai haɗin JZ shine babban haɗin tsakanin DS200DACAG1A module da JPDF module. Yana da 12-matsayi plug-in haši wanda ke haɗa ta hanyar igiyar igiya zuwa mai haɗin JZ2 ko JZ3 na tsarin JPDF, yana ɗauke da shigarwar AC da siginar fitarwa na DC.

Rukunin Pin Siginar Bayanin
Shigar AC Layi / Neutral 115/230 V ac shigarwar daga JPDF module
Fitar da DC DC+ / DC- 125V dc fitarwa yana dawowa zuwa JPDF module

2. JTX1 da JTX2 Connectors

JTX1 da JTX2 masu haɗin kebul na ciki ne da ake amfani da su don zaɓar kewayon shigarwar ƙarfin lantarki:

Zaɓin Input Voltage Mai Haɗi Bayanin
Farashin JTX1 115V AC shigarwar Toshe kebul na ciki cikin wannan haɗin don zaɓar shigarwar 115 V
Farashin JTX2 230V AC shigarwar Toshe kebul na ciki cikin wannan haɗin don zaɓar shigarwar 230 V

V. Shigarwa da Kulawa

1. Wuri Mai hawa

An ɗora tsarin DS200DACAG1A akan bene na majalisar ministoci a cikin yankin rarraba wutar lantarki, an amintar da shi da maƙallan hawa huɗu. Ya kamata a shigar da tsarin a wurin da ke sauƙaƙe igiyoyi da kulawa.

2. Matakan Shigarwa

  1. Tabbatar da An kashe Wuta: Tabbatar cewa an kashe wutar tsarin Mark VIe kuma gwada don tabbatar da babu wutar lantarki.

  2. Nemo Matsayin Hawa: Gano wurin hawa a bene na majalisar, tabbatar da isasshen sarari ga madaidaitan madaukai guda huɗu.

  3. Shigar da Maɓalli: Aminta da tsarin DACA zuwa bene na majalisar ministoci ta amfani da maƙallan hawa huɗu.

  4. Haɗa Harness: Haɗa mai haɗin JZ na tsarin DACA zuwa mai haɗin JZ2 ko JZ3 na JPDF module ta hanyar kayan haɗin kebul.

  5. Zaɓi Input Voltage: Dangane da ƙarfin wutar lantarki na rukunin yanar gizon, toshe kebul na ciki zuwa JTX1 (115 V) ko JTX2 (230 V).

  6. Ƙarƙashin ƙasa: Tabbatar cewa ƙirar ta kasance cikin dogaro da ƙarfi ta hanyar maƙallan hawa.

  7. Kunnawa da Tabbatarwa: Bayan amfani da wutar lantarki, yi amfani da multimeter don bincika cewa ƙarfin wutar lantarki ya dace da ƙayyadaddun bayanai.

3. Matakan Cire

  1. Tabbatar da Ƙarfin Ƙarfi: Tabbatar cewa an cire ƙarfin tsarin kuma gwada don tabbatar da cewa babu wutar lantarki.

  2. Cire haɗin Harness: A hankali cire haɗin haɗin haɗin JZ.

  3. Cire Brackets: Sake maƙallan bango guda huɗu kuma cire tsarin DACA.

4. Shawarwari na Kulawa

  • Dubawa na lokaci-lokaci: a kai a kai duba masu haɗin ƙirar don sako-sako da ƙwanƙwasa ƙwanƙwasa.

  • Kula da Yanayin Zazzabi: Kula da yanayin yanayin zafin aiki don tabbatar da isassun iska kuma babu zafi mai yawa.

  • Duban Wutar Lantarki: Lokaci-lokaci auna ƙarfin fitarwa don tabbatar da ya kasance cikin ƙayyadaddun bayanai.

  • Gudanar da Sassan Kayan Aiki: Ana ba da shawarar kiyaye aƙalla tsarin DACA iri ɗaya a kan rukunin yanar gizon a matsayin abin da zai rage lokacin raguwa.

VI. Aikace-aikace

Module Canjin Wuta na DS200DACAG1A AC-Dc ana amfani dashi sosai a cikin aikace-aikacen masana'antu masu zuwa:

  • Mark VIe Control Systems: A matsayin babban ɓangaren tsarin PDM, yana ba da ikon 125 V dc zuwa tsarin sarrafawa.

  • Tsarin Kula da Shuka Wuta: Canza wutar AC zuwa DC a cikin tsarin sarrafa wutar lantarki don samar da kayan sarrafawa.

  • Tsarin Kula da Turbine: Samar da ingantaccen ƙarfin aiki na DC don tsarin sarrafa injin turbine Mark VIe.

  • Gudanar da Tsarin Masana'antu: Samar da canjin wuta a aikace-aikacen sarrafa masana'antu da ke buƙatar juyawa AC-DC.

  • Tsarukan Wutar Lantarki: Yin aiki tare tare da ƙarfin baturi don gina ingantaccen tsarin wutar lantarki.

Ƙayyadaddun sigogi
Lambar Samfura Saukewa: DS200DACAG1A
Jerin Samfura Module Canjin Wuta na DACA Ac-Dc
Tsarin Da Aka Aiwatar Da Shi Mark VIe Tsarin Rarraba Wutar Lantarki na Modular (PDM)
Input Voltage 115V ac ko 230V ac, 47 zuwa 63 Hz
Input Voltage Range 105-132V ac (saitin 115V)
210-265V ac (saitin 230V)
Fitar Wutar Lantarki 90 zuwa 140V dc (tare da 1 zuwa 9.5 A kaya)
Fitowar Yanzu 9.2 A (shigarwar 120V, cikakken kaya)
9.3 A (shigarwar 240V, cikakken kaya)
Ƙarfin fitarwa Kimanin 500 W
No-Load Fitar Wutar Lantarki 130V (shigarwar 120V)
130.6V (shigarwar 240V)
Wutar Lantarki na Cikakkun Load 105.6V (shigarwar 120V)
111.8V (shigarwar 240V)
Fitar da Voltage Ripple 2.92V ganiya-zuwa kololuwa (shigarwar 120V)
3.56V ganiya-zuwa-kolo (shigarwar 240V)
Amsa Matakin Fitowa 106V zuwa 132V dc (shigarwar 120V)
111V zuwa 131V dc (shigarwar 240V)
Yawan fitarwa Babu kaya, fitarwa zuwa ƙasa da 50 V dc a cikin minti 1 bayan shigar da wutar lantarki
Yanayin Aiki -30°C zuwa 65°C (-22°F zuwa 149°F), sanyaya convection
Danshi na Dangi 5% zuwa 95%, ba condensing
Matsayin Tsaro UL 508A, CSA 22.2 Lamba 14, IEC 1010-1
Matsayin EMC IEC 801-2 (ESD), ENV 50140 (Radiated RF rigakafi), EN 50082-2 (Gidan masana'antu na rigakafi gabaɗaya), IEC 801-4 (masu saurin wutar lantarki), IEC 1000-4-5 (ciwon rigakafi), IEC 1000-4-6 rigakafi
Ƙididdiga na Ƙalla IEC 529 / NEMA 1 / IP 20
Hanyar hawa Amintacce zuwa bene na majalisa tare da maƙallan hawa huɗu
Hanyar haɗi Mai haɗin JZ mai matsayi 12 guda ɗaya zuwa JPDF module
Na baya: 
Na gaba: 

Hanyoyi masu sauri

Kayayyakin

OEM

Tuntube Mu

 Waya: +86-181-0690-6650
 WhatsApp: +86 18106906650
 Imel:  sales2@exstar-automation.com / lily@htechplc.com
 Adireshi: Daki 1904, Ginin B, Kogin Diamond, Lamba 96 Titin Lujiang, Gundumar Siming, Xiamen Fujian, China
Haƙƙin mallaka © 2025 Exstar Automation Services Co., Ltd. Duk haƙƙin mallaka.