The IQS900 Signal Conditioner is a high-performance, modular, core component of the non-contact eddy current displacement measurement system from Parker Meggitt (formerly the vibro-meter product line). This product works in conjunction with the TQ402/TQ412 series eddy current sensors and the EA402 extension cable to form a complete displacement/vibration measurement system. It is widely used for real-time measurement of parameters such as relative shaft vibration, axial displacement, eccentricity, and rotational speed in rotating machinery, including steam turbines, compressors, pumps, and generators.


The IQS900 is the upgraded replacement for the IQS450, featuring higher electromagnetic compatibility, enhanced interference immunity, lower output impedance, and supports SIL 2 functional safety design. It is suitable for long-term, stable operation in harsh industrial environments such as automation, petrochemicals, power generation, and metallurgy.


The specific model IQS900 204-900-000-011 A1-B21-C1-H05-I0 is a high-precision, standard industrial version (non-Ex), featuring voltage output (for a 2 mm measurement range), no diagnostic functions, and a standard connector configuration. It is suitable for rotating machinery monitoring applications requiring high measurement accuracy, supports DIN-rail mounting, and is widely used in protection systems conforming to API 670 standards.



II. Key Features and Benefits

  • Non-contact eddy current measurement principle: Based on high-frequency electromagnetic field induction, suitable for dynamic and static measurements of high-speed rotating machinery, unaffected by media such as oil and water vapor.

  • High sensitivity measurement: 2 mm linear measurement range, high sensitivity of 8 mV/μm, output signal -1.6 V ~ -17.6 V, suitable for high-precision measurement of small gaps.

  • Wide frequency response: DC ~ 20 kHz (-3 dB), capable of measuring both static displacement and dynamic vibration simultaneously.

  • Low output impedance: < 100 Ω (DC), < 300 Ω (20 kHz), supporting long-distance signal transmission with good compatibility with various monitoring systems.

  • SIL 2 functional safety design: Compliant with IEC 61508, suitable for safety-related applications (the C2 diagnostic version has SIL 2 certification; the C1 model has no diagnostics but the hardware design meets SIL 2 capability).

  • Temperature-compensated design: Ensures measurement stability across the full temperature range (-40°C ~ +85°C).

  • Modular design: Features plug-in screw terminals, simplifying on-site wiring and maintenance.

  • DIN-rail mounting: Supports standard TH 35 rails for easy installation.

  • Multiple output options: Configurable for voltage or current output to meet different system interface requirements.

  • High interference immunity: Improved electromagnetic compatibility design, compliant with EN 61000-6-2/4 standards.

  • Overvoltage/Short-circuit protection: Outputs feature overvoltage and short-circuit protection, enhancing system reliability.

  • System components interchangeable: Sensors, cables, and signal conditioners are all interchangeable without requiring recalibration.



III. Typical Applications

  • Steam Turbines, Hydraulic Turbines, Gas Turbines: Shaft vibration, axial position monitoring.

  • Compressors, Blowers: Rotor dynamic behavior analysis, axial thrust monitoring.

  • Pumps: Eccentricity, rotational speed, vibration monitoring.

  • Generators, Electric Motors: Shaft vibration and air gap monitoring.

  • Gearboxes: Shaft vibration and position monitoring.

  • Fans, Blowers: Vibration and gap monitoring.

  • API 670 Standard Protection Systems: Rotating machinery protection systems conforming to international standards.

  • Laboratories and Test Stands: For displacement and vibration characteristic research.



IV. System Composition and Operating Principle

4.1 System Composition

The IQS900 Signal Conditioner, together with the TQ402/TQ412 sensor and the EA402 extension cable, forms a complete eddy current displacement measurement system. All components are calibrated and interchangeable without the need for recalibration.

  • TQ402/TQ412 Sensors:

    • TQ402: Standard mount type, contains an 8 mm diameter coil encapsulated in a Torlon® probe tip, a stainless steel body (AISI 316L), an integral coaxial cable with FEP sheath, terminated with a self-locking miniature coaxial connector. The probe is available with metric or imperial thread options.

    • TQ412: Reverse mount type, suitable for applications with limited installation space; other specifications are identical to the TQ402.

  • EA402 Extension Cable: Used to extend the distance between the sensor and the signal conditioner, featuring self-locking miniature coaxial connectors at both ends, available in various lengths to support 1 m, 5 m, and 10 m total system length combinations.

  • IQS900 Signal Conditioner: Contains a high-frequency modulator/demodulator circuit, provides the excitation signal for the sensor, and converts the sensor's impedance change into a voltage or current signal proportional to the gap.

4.2 Operating Principle

  1. Sensor Excitation: The internal high-frequency oscillator in the IQS900 generates an excitation signal, driving the sensor coil via the cable and creating a high-frequency electromagnetic field around it.

  2. Target Interaction: When a metallic target (e.g., a rotating shaft) approaches the sensor tip, eddy currents are induced on the target surface. These currents react back on the sensor coil, altering its equivalent impedance.

  3. Demodulation and Output: The modulation/demodulation circuit inside the IQS900 detects the impedance change and converts it into a voltage or current signal linearly proportional to the target gap.

  4. Signal Transmission: The output signal can be directly connected to monitoring systems like VM600, VibroSmart, or for data acquisition and analysis via PLC/DCS.



V. Model Code Breakdown (IQS900 204-900-000-011 A1-B21-C1-H05-I0)

Code Segment Description
IQS900 Base model: Signal conditioner, part of the vibro-meter product line
204-900-000-011 Internal version number or specific configuration identifier
A1 Option Code: Standard industrial version, no Ex certification (non-Ex)
B21 Measurement Range & Output Type: 2 mm measurement range, voltage output, sensitivity 8 mV/μm
C1 Diagnostic Function: No diagnostics (C2 indicates with diagnostics)
H05 Housing & Connector Configuration: Standard metal housing with plug-in screw terminals
I0 Interface Option: Standard connector configuration, no special interface requirements

Note: The exact meaning of model codes may change with product revisions. It is recommended to confirm with the latest data sheet or official information from Parker Meggitt.



VI. Performance Curves (Typical)

(Reference performance curves for TQ402/TQ412 with IQS900)

  • Output Characteristic: With standard target material (VCL 140 steel) at 23°C calibration temperature, output voltage is linear with gap, slope 8 mV/μm, linear range 0.15 ~ 2.15 mm.

  • Error Curve: Typical linearity error < ±50 μm (relative to ideal straight line) over the entire measurement range.

  • Temperature Drift: Maximum temperature drift < 5% over the range -40°C ~ +180°C.

(Specific curves can be found in the TQ402/TQ412/EA402/IQS900 data sheet, pages 8-9)



VII. Installation and Mechanical Dimensions

7.1 IQS900 Signal Conditioner Dimensions

  • Width: Approx. 100 mm

  • Height: Approx. 80 mm

  • Depth: Approx. 30 mm (excluding connectors)

7.2 Mounting Methods

  • Direct Screw Mounting: Via two M4 screws onto a mounting plate or inside a cabinet.

  • DIN-rail Mounting: Using the MA130 rail adapter for quick installation on TH 35 rails (compliant with EN 50022 / IEC 60715).

7.3 Connector Layout

  • Sensor Input: Self-locking miniature coaxial connector (labeled "SENSOR").

  • Test Interface: 4-pin terminal block, including RAW and TEST signals.

  • Power & Output: 4-pin terminal block, including O/P and -24V/COM.

7.4 Installation Notes

  • The IQS900 has an IP20 rating and is suitable for indoor use only. For harsh environments, it must be installed in a cabinet with IP54 or higher protection.

  • Ensure cable connections are secure; coaxial connectors should be hand-tightened until they lock.

  • Terminal blocks are pluggable, facilitating pre-wiring.



VIII. Accessories and Options


Accessory Name Model Description
DIN-rail Mounting Adapter MA130 For mounting IQS900 on TH 35 rails
Industrial Protection Enclosure ABA17x Provides higher ingress protection (IP54+), suitable for field installation
Interconnection Protector IP172 Protects the sensor-to-cable connection point, oil and water resistant
Junction Box JB118 For centralized wiring of multi-channel signal conditioners
Flexible Conduit KS107 Provides mechanical protection for sensor cables
Cable Feedthrough SG1xx For sealing and fixing cables entering a cabinet
Probe Mounting Adapter PA15x For mechanical positioning of TQ402/TQ412 sensors
Extension Cable EA402 Available lengths: 0.5 m, 1.0 m, 1.5 m, 2.0 m, 3.0 m, 3.5 m, 4.0 m, 4.5 m, 5.0 m, 8.0 m, 8.5 m, 9.0 m, 9.5 m, 10.0 m, etc. (must be combined to achieve total system lengths of 1 m, 5 m, or 10 m)
Sensor TQ402 / TQ412 2 mm range sensor, available with different integral cable lengths, selectable standard or reverse mounting




IX. Total System Length and Cable Combinations

When the IQS900 is used with TQ402/TQ412 and EA402, the supported Total System Lengths (TSL) are 1 m, 5 m, and 10 m, with the following combinations:

Total System Length Sensor Cable Length Extension Cable Length
1 m 1.0 m None
5 m 0.5 m 4.5 m
5 m 1.0 m 4.0 m
5 m 1.5 m 3.5 m
5 m 2.0 m 3.0 m
5 m 5.0 m None
10 m 0.5 m 9.5 m
10 m 1.0 m 9.0 m
10 m 1.5 m 8.5 m
10 m 2.0 m 8.0 m
10 m 5.0 m 5.0 m
10 m 10.0 m None

Cable Length Trimming: Due to the electrical characteristics of the coaxial cable, the actual cable length requires electrical trimming to ensure system performance. For example:

  • Minimum actual length for a 1 m system: 0.9 m

  • Minimum actual length for a 5 m system: 4.4 m

  • Minimum actual length for a 10 m system: 8.8 m

(Refer to the data sheet for specific trimming values.)



X. Compatible Monitoring Systems

The output signal from the IQS900 Signal Conditioner can be directly connected to the following monitoring systems:

  • VM600 / VM600 Mk2 Series Modules (e.g., IOC4T, IOC16T)

  • VibroSmart® Distributed Monitoring System (e.g., VSM100, VSM101)

  • GS1127 Galvanic Isolation Unit (for safety barrier isolation)

  • Third-party PLC/DCS Analog Input Modules (must meet input impedance requirements: voltage input ≥ 50 kΩ, current input ≤ 350 Ω)



XI. Certifications and Standards

Certification Type Standard / Body Description
CE Marking European Union Compliant with EU EMC and Low Voltage Directives
EAC Marking Eurasian Economic Union Applicable for Russia, Kazakhstan, etc.
RoHS 2011/65/EU Compliant with Restriction of Hazardous Substances
Electromagnetic Compatibility EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions) Suitable for industrial environments
Electrical Safety EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use
Functional Safety IEC 61508 (SIL 2) Hardware design meets SIL 2 capability (C2 version is certified)
Ingress Protection IEC 60529 IP20 (requires installation in an enclosure)

Note: This model with code A1 is the standard industrial version and does not have explosion-proof certification. For use in hazardous areas, the A5 Ex option should be selected for the signal conditioner. The TQ402/TQ412 sensors and EA402 cable are available in Ex versions (e.g., A2 Intrinsic Safety, A3 Non-sparking); refer to the data sheet for details.



XII. Ordering Information

Component Model Description
Signal Conditioner IQS900 204-900-000-011 A1-B21-C1-H05-I0 2 mm range, voltage output, no diagnostics, standard type, with H05 housing and I0 interface
Sensor TQ402-xxx or TQ412-xxx Select integral cable length and mounting type (standard or reverse) as needed
Extension Cable EA402-xxx Select length as needed (e.g., 4.5 m, 5.0 m, 9.0 m, etc.)
Mounting Adapter MA130 Optional DIN-rail mounting

Note: Please consult Parker Meggitt or an authorized distributor for specific ordering part numbers.




Parameter Category Specification
Product Name IQS900 Eddy Current Displacement Measurement System Signal Conditioner
Model IQS900 204-900-000-011 A1-B21-C1-H05-I0
Compatible Sensors TQ402 / TQ412 Series (2 mm range)
Compatible Extension Cable EA402 Series
Measurement Principle High-frequency Eddy Current
Measurement Range 2 mm (Linear range: 0.15 ~ 2.15 mm)
Output Type Voltage output (3-wire)
Sensitivity 8 mV/μm (200 mV/mil)
Output Signal Range -1.6 V ~ -17.6 V (corresponding to min. to max. gap)
Frequency Response DC ~ 20 kHz (-3 dB)
Linearity See performance curves (typical error < ±1%)
Interchangeability All system components (sensor, cable, conditioner) are interchangeable without recalibration
Output Impedance < 100 Ω (DC), < 300 Ω (20 kHz)
Load Requirement Monitoring system input impedance ≥ 50 kΩ (recommended)
Raw Output (RAW) -0.8 V ~ -8.8 V (nominal), output impedance < 15 kΩ (DC)
Test Input (TEST) Input voltage range ±0.1 ~ 4.0 Vp-p, input impedance 500 kΩ
Power Supply Voltage -19 V ~ -30 VDC (voltage output mode)
Power Consumption < 25 mA @ -24 VDC
Overvoltage Protection -33 VDC (typical)
Short-circuit Protection Outputs protected against short circuits (35 mA current limiting)
Operating Temperature -40°C ~ +85°C
Storage Temperature -40°C ~ +85°C
Humidity Range 0 ~ 95% RH (non-condensing)
Ingress Protection Rating IP20 (Requires installation in an enclosure with at least IP54 rating)
Flammability Rating UL94 V-0
Vibration Resistance 5 g (10 ~ 500 Hz)
Shock Resistance 15 g (11 ms half-sine wave)
Housing Material Painted aluminum alloy
Electrical Connections Sensor side: Self-locking miniature coaxial connector; Power/Output side: Plug-in screw terminals (supports 0.2 ~ 1.5 mm² wire)
Mounting Method Two M4 screws, or via MA130 adapter for TH 35 rail
Weight Approx. 200 g (without adapter)
Dimensions Refer to mechanical drawings (approx. 100 mm × 80 mm × 30 mm)
Compliant Standards CE, EAC, RoHS, EN 61000-6-2/4, EN 61326-1/3-2, EN 61010-1

Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email:  sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.