nyban1
Hic es: Home » Systems » Turbine Supervisory Instrumentation » VM600 Machinery Protection Systems » IOCN Mk2 600-051-000-001 Input/Output Communicationis interface Module
Relinque nobis Nuntius

loading

IOCN Mk2 600-051-000-001 Input/Output Communication Interface Module

  • VM

  • 600-051-000-vvv

  • $2200

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

VM600 IOCN Mk2 elementum magni ponderis est lineae producti VM pro VM600 Mk2 (secunda generatio) systematis eculei substructio vigilantia. Huic appositionis input/output et communicationis interfaciendi moduli inservit pro CPUM Mk2 eculeo moderatoris moduli. IOCN Mk2 et CPUM Mk2 unum par moduli complent, systematis imperium, portae communicationis datas praebent, et signum interfaciendi munera pro systemate VM600 Mk2 constituunt.


Destinatus ad ambitus industriales, hic modulus late adhibetur in machinis tutelae et conditionis vigilantia systemata generationis potentiae, olei et gasi, aliarumque industriarum. Productum secundum generationem, IOCN Mk2 emendationes significantes praebet super IOCN moduli primi generationis in terminis architecturae ferrariae, perficiendi communicationis, integrationis systematis et constantiae.


Differentiae key inter IOCN Mk2 et IOCN

1. Hardware Architecture Differentiae

Pluma IOCN (generatio prima) IOCN Mk2 (Secunda generatio)
OMNIBUS Latitudo Unius latitudo Unius latitudo
Matching Controller CPUM. CPUM Mk2
Summa Slote Occupation 3 foramina (CPUM duplex latitudo + IOCN unius latitudo) 2 foramina (CPUM Mk2 una-latitudo + IOCN Mk2 unius latitudo)
Module Structure Basic interface functiones Consectetur interface munera

2. Differentiae Communication Capability

Communicatio Feature IOCN (generatio prima) IOCN Mk2 (Secunda generatio)
Systema Ethernet 10/100BASE-TX (max 100Mbps) 10/100/1000BASE-T(X) (max 1Gbps)
Fieldbus Support Modbus RTU/TCP, PROFINET Modbus TCP, PROFIBUS DP
Vide Interfaces Usque ad III RS-232/RS-422/RS-485 2 RS-485 (PROFIBUS DP)
Dundantia Support stricto auxilio Omni moduli gradu et eculeo gradu addita sustentatio

3. euismod Aliquam

IOCN Mk2 significantes emendationes in communicationis effectu ostendit:

  • Celeritas Transmissio: Ethernet interfaces upgraded ab Fast Ethernet ad Gigabit Ethernet, 10x velocior velocitas transmissionis

  • Facultas processus: Suscipio communicationis campi velocitatis altioris (PROFIBUS DP usque ad 12Mbps)

  • Responsio temporis: Velocius signum transmissionis et celeritatis processus, ratio brevioris temporis responsionis

4. Compatibility Differentiae

  • Deinceps convenientiae: IOCN Mk2 solum compatitur cum systematibus VM600 Mk2, non compatitur cum primaeva VM600 pecto

  • Retrorsum compatibilitas: IOCN Mk2 compatitur omnibus VM600 Mk2 ratio quatit

  • Software compatibilitas: IOCN Mk2 requirit VibroSight software pro configuratione

5. Eget Differentiae Characteres

Feature IOCN (First Generation) IOCN Mk2 (Secunda generatio)
Solitudo euismod Basic solitudo praesidium Consectetur solitudo tutela cum superiore intentione solitudo
Functions diagnostica Basic status indicium Consectetur diagnostic et status magna
Configurationis Management Hardware configuratione usura jumpers Configuratio programmatis plena, non requiritur jumpers
Redundancy functiones Limitata addita auxilium Complete additamentum subsidium, sustentans figurationes complexas

6. Application Scope Varietas

  • IOCN: Apta ad rationes VM600 traditionales, maxime ad machinamenta applicationes tutelae

  • IOCN Mk2: Disposita specialiter ad systemata VM600 Mk2, fovens latiorem applicationem missionum et requisita altiora perficiendi

7. Differentiae Physicae

Physica Feature IOCN (generatio prima) IOCN Mk2 (Secunda generatio)
Dimensiones 6U altitudo, 20mm latitudo, 125mm profunditas 6U altitudo, 20mm latitudo, 125mm profunditas
Pondus circa 0.25kg circa 0.25kg
Connectors Varias species (D-sub, RJ45, RJ12); Optimized connector layout supporting superior speeds


Key Features et functiones

Communication 1. interface functiones

IOCN Mk2 modulus plures communicationes praebet interfaces adiuvantes systema Aer et campi communicationis:

Systema Aer Interfaces:

  • Duo 10/100/1000BASE-T(X) portus Aethernet (ETHERNET1 et ETHERNET2)

  • Support pro gigabit communicationis (usque ad I Gbps)

  • Usus est ad communicationem cum VibroSight® programmatis et XMx16+ IO16T modulorum

Fieldbus Interfaces:

  • Duo portus sui iuris agri (FIELDBUS1 et FIELDBUS2)

  • Quisque portus unum continet RS-485 Vide interface et unum Aer interface

  • Support pro Modbus TCP et PROFIBUS DP protocolla

  • Firmamentum est simultaneum operationi dualorum agrorum, ut communicationem vacet

2. signum Praesidium functiones

  • Electromagneticam intercessionem praebet (Hypern) et fluctuum praesidio omnibus initus significationibus

  • Prosequitur electro convenientiae (EMC) signis

  • RS-485 interface solitudo voltage: 700 Vrms

  • Aer interfaciei solitudo voltage: 1500 Vrms

3. Nullam output functiones

  • Duo user-configurabiles mensas (RL1 et RL2)

  • Unius polus duplex iactus (SPDT / Forma C) genus

  • Ratum voltage: 240 VAC, aestimavit current: 5 A

  • Deformari potest per Modbus aliquantulum variabilium pro remota indicatione status systematis et terroris informationis

4. Status indicium functiones

  • Ante tabulam instructam multis indicibus DUXERIT

  • Systema Aer et fieldbus communicationis status exhibet

  • Vinculum et actionem praebet status indicia

5. Hot-Swpping Support

  • Modulus subsidia permutando functionality calidum-

  • Ratio automatice agnoscit et reconfiguret, systema melius disponibilitatem et efficientiam conservandam


Principium opus

1. Systema Architecturae et Partes Positioning

Modulus IOCN Mk2 pro signo et communicatione extensionis pro CPUM Mk2 inservit, notitia commutans cum CPUM Mk2 per VM600 Mk2 backplanum eculeum. Partes eius principales sunt:

Communicatio interface Munus:

  • Connexionem physicam praebet interfacies, CPUM Mk2 munera communicationis logicae in significationibus actualibus corporis convertens

  • Omnes communicationis externae necessitudines, inter quas ratio Aer et fieldus interfaces administrat

  • Solitudinem electricam et tutelam praebet, operandi ratio stabilis in ambitus industriae dura praestans

Munus interface signum:

  • Nullam output interfaces praebet, systematis status et terror informationes convertens in contactu sicco annuit

  • Administrat notam electricam matching et tutelam omnibus input et output significationibus

2. Data Flow Processing

Processus notitiae processus IOCN Mk2 in systematis est hoc modo:

Data Receptio Path:

  • Imperium imperat ac notitias petitiones ab externis machinis (ut DCS, PLC) per fieldbus accipit

  • Configurationem accipit et mandata vigilantia a VibroSight software per systema Aer

  • Has signa vertit in formas transmissionis ad backplanam aptas et eas ad CPUM Mk2 transmittit ad expediendas.

Data Transmissio Path:

  • Data processus et status informationes accipit ex CPUM Mk2

  • Transmittit notitia ad tertiam partem systemata per fieldbus interfaces

  • Data vigilantia software per systema Aer interfaces mittit

  • Outputs specifica status notitia per mensas fundatur configuratione

3. Electrical solitudo Mechanismus

IOCN Mk2 consilio solitario electricam multiplici utitur:

  • Fieldbus interfaces magneticam vel opticam solitudo technologia utuntur

  • Systema Aer interfacies uti TRANSFIGURATOR solitudo

  • Nullam outputs uti corporalis solitudo

  • Omnes interfaces ad solitudo exigentias pertinentes ad salutem signa

4. Redundancy Opus Mechanismum

Cum in modum redundantia figuratur, duo IOCN Mk2 moduli collaborative laborant:

  • Commercium utriusque moduli domini et servi simul agunt, dum vias communicationis supervacuas praebent

  • Lorem link status deprehensio dat inconsutilem mutandi

  • Configurationes communicationis universa subsidia in occursum promptitudinis requisita


Technical Specifications Summary

  • Power Requirements: Powered by VM600 RPS6U eculeo potentiae copiae, 5VDC, maximam vim consummationis 1W

  • Temperatus operans: 0°C ad 65°C (prout onus Nullam)

  • Communicationis interfaces: 2 systematis Aer (10/100/1000BASE-T), 2 fieldbus portus

  • Voltage: RS-485 interface 700Vrms, Aer interface 1500Vrms

  • Obsequium signa: CE, EN 61010-1, EN 61326-3-1, RoHS, etc.


Application missiones

IOCN Mk2 modulus aptus est pro missionibus sequentibus:

  • Vibratio tutelae et conditionis systemata vigilantia turbines (fumoris, gas, hydro) in plantis potentiae

  • Cras machinae rotationis ut compressores, soleatus et fans in industria oleum et gas

  • Applicationes criticae postulant promptitudinis et superuacanea figurarum

  • Integratio cum systematibus controlalibus ut DCS et PLC pro notitia communicationis et iunctionis potestate


CPUM Mk2 (2)CPUM Mk2 (3)CPUM Mk2 (4)CPUM Mk2 (5)CPUM Mk2 (6)CPUM Mk2 (7).CPUM Mk2 (8).CPUM Mk2 (9).CPUM Mk2 (10).CPUM Mk2 (11).CPUM Mk2 (12)CPUM Mk2 (13).CPUM Mk2 (14)CPUM Mk2 (15)CPUM Mk2 (16)CPUM Mk2 (17)

CPUM Mk2 (18).

Priora: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
Email  :  sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.