nyban1
Hic es: Home » Systems » Turbine Supervisory Instrumentation » VM600 Machinery Protection Systems » XMV16 620-003-001-116 Extensa Vibratio Monitoring Module
Relinque nobis Nuntius

loading

XMV16 620-003-001-116 Extensa Vibratio Cras Module

  • VM

  • 600-003-VVV-VVV

  • $7500

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

VM600 XMV16 Extensa Vibratio Module Monitoring est altera-generatio summus perficientur vigilantia solutionis solutionis ex linea VM producti, specie ad vibrationem monitoriam et analysim machinae rotationis criticae destinatae. Ut elementum essentiale systematis VM600 Mk2/VM600, opera XMV16 tandem cum IO16T input/output moduli ad tradendum summo ordini vigilantia perficiendi cum 16 canalibus dynamicis et 4 canalibus tachometris. Modulus provectior 24-bitrum notitiarum technologiarum acquirendi utitur et potens digitalis processui facultatum insignium, ut alta resolutio spectri analysis usque ad 6400 lineas habeat, inaudita machina salutis pervestigationes pro usoribus industrialibus providens.


Modulus XMV16 novissimam progressionem in vibratione technologiae vigilantiae repraesentat, praebens emendationes significantes super suum praedecessorem, par CMC16/IOC16T, secundum amplitudinem et solutionem spectralis, facultatem memoriae quiddam, potentiae moduli-gradus processus, ac data acquisitione ac tabulario. Modulus VM programmatis seamlessly integrat, potens summus solutionis consilium praebens, notitias integrales administrandi, et accessum retis faciliorem interfaces, faciens optimam electionem pro modernis systematibus predictive sustentationis.



Key Features

1. summus euismod Data Acquisitione & Processing

In XMV16 utitur 24-bis analogicis ad digitales conversionem cum maximo sampling rate of 98 kHz, ut summus fidelitas vibrationis signum acquisitionis obtineat. Modulus praebet rationem (SNR) egregiae significationis (SNR) perficiendi: 115 dB ad 1 kHz mensuram longitudinis cum 2.5 V apicem librae plenae, 105 dB ad 10 kHz latitudinem, et 100 dB ad latitudinem plenam. Haec alta observantia praestat accurate et certa magna notitias etiam in ambitus industriae exigente.

2. Multi-modus mensurae capacitatem

Modulus tres modos mensurae distinctos sustinet ut variis vigilantiae necessitatibus occurrant;

  • Principalis modus: Principaliter usus pro continua notitia acquisitionis in operatione normali machinae, apta ad vigilantiam crescentes gradus vibrationis et condiciones caducas.

  • Modus auxiliaris: plus acquirit waveforms ac spectris notitias reductas update rates, modum principalem mensuras complens

  • Directus Modus: Adipiscendae diuturnae diuturnae continuae waveforms ex dynamicis input canalibus praecedentibus eventus terroris ad explicationem post-analysin

3. High-Resolutions Spectrum Analysis

XMV16 solutionem spectralis industriae praebet usque ad 6400 lineas (recensendas undae puncto 16384). Diversae resolutiones diversis rates renovatis respondent: spectra spectra 1600-linea renovatio omnis 100 ms, 3200 linea spectra omnis 200 ms, 6400 linea spectra omnis 500 ms. Hoc altum consilium dat subtilissimae deprehendendi culpae naturas.

4. Flexibile configurationis Options

Singuli canales configurari possunt cum usque ad 20 outputs discursum secundum asynchrone (frequentia certa) vel synchrone (ordo-vestigatum) fluctus formas et spectras acquisitas. Munera adjuncto multiplex sustentantur, inter RMS, cacumen, cacumen ad apicem, verum cacumen, verum cacumen-ad apicem, et DC (Gap). Outputs in quolibet signo unitatis (metrico vel imperatorio exponi potest).

5. potens signum Socius Capability

XMV16 subsidia communicationis in VM600 Mk2/VM600 signum eculei, ut dynamicam input signorum communicationem per rudis (usque ad 32 lineas) sustineat et tachometer input signum communicationis per Tacho bus (usque ad 6 lineas). Hoc consilium signanter redigit externam wiring requisita et systema integrationem simplificat.

6. Provectus Vicis Excipio Functionality

Modulus praebet configurabiles prae felis et post-triggerum datas facultates colligationis. Pre-felis notitia logging potest usque ad singulas 100 ms pervenire, dum post-felis notitia colligationis etiam potest consequi usque ad singulas 100 ms durationes usque ad horam 1 . Onboard quiddam memoriae recondere potest usque ad 1140 notitias statas (extractas notitias) et 42 datas dynamicas (undationes et/vel spectras).

7. Multiplex averaging et aggregatio Methodi

Varii fere modi sustentantur in utroque gradu processus obstructionum et output (extracta notitia) gradu. Datae congregationis spectris super unam secundam, etiam praesto est ut excipiant omnes rupta vel spicula in spectris internis XMV16 moduli.

8. Multi-canale Processing functiones

Provectus functiones processus fulciuntur, inter hastile vibrationis absolutae, spectrum plenum, orbita et percolata orbita, scapus centerline, et Smax, occurrentes dynamica rotoris complexi analyseos requisita.

9. Gigabit Ethernet Communication

The module features a Gigabit Ethernet interface supporting data transferre rates usque ad 1000 Mbps. Ante-panel AETERNET iungens spatia transmissionis ad 100 metra sustinet, cum iungo posterioris tabulae usque ad 60 metra sustinet, praestantem flexibilitatem ad integrationem systematis praebens.

10. Hot-VERTO Facultas

Sustinet insertio et amotio modulorum (calidi-swappable) sine interpellatione systematis operandi, signanter augendi systema conservabilitatem et promptitudinem.

11. Aliquam Aliquam Adaptability

Temperatura range operans: 0 ad 65°C (32 ad 149°F)
Repono range temperatura: -40 ad 85°C (-40 ad 185°F)
humiditas operans: 0 ad 90% humiditas relativa (non-condensing)
RoHS obsecundanti aptae environmental aptabilitas.

12. Salutis certificaciones

EAC notata, obsecundantia cum TR CU 020/2011 signis compatibilitatis electromagneticae et TR CU 004/2011 signa electrica tuta. Certificatum a Russica Procuratio Foederalis pro Regulatione Technica et Metrologia (Rosstandart) cum approbatione certificamenti OC.C.28.004.AN° 60224.



Principium opus

Protractum Vibrationis Vibrationis Monitoring Module Operationis principium VM600 XMV 16 fundatur in processui technologiae signo digitali progresso. Operans in conjunctione cum modulo IO16T input/output, magna vigilantia et analysi machinae vibrationis condiciones comprehendit. Principium operans in plures aspectus clavis dividi potest;

1. Ratio Architecture & Signum fluunt

Processus moduli XMV16 in fronte equulei inauguratus est, dum IO16T modulus in tergo inauguratus est. Ambae directe connectunt in eculeo per connexiones. Signa sensoria per IO16T moduli terminatio clausus iunctio initus sunt, ubi signum conditionem et tutelam subeunt antequam ad XMV16 moduli transmittantur ad processus per backplanum.

Modulus IO16T omnes condiciones significationis analogas praestat et communicationes externas sustinet. Omnia initibus tutatur contra insignes aestus et EMI obviam EMC signis. Moduli initibus plene programmatibus configurabiles sunt ac signa recipere possunt celeritatem et periodum referentiae repraesentantes (ex. gr. sensoriis TQxxx) necnon vibrationum signa ex acceleratione, velocitate et/vel obsessione orta (ex. gr. a CAxxx, CExxx, CVxxx, et TQxxx sensoriis).

2. Signum Acquisitionis & Digitization

Modulus XMV16 in conversione analogica ad digitalem et omnes functiones processus signos digitales, incluso processu cuiusque fluctus et spectri, et outputs processit affinis (extracta notitia). Modulus acquirit et processus notitias in alta resolutione (24-bit ADC) ad generandas formas et spectras utens tribus modis mensuris diversis: principalem, auxiliarem et directam.

In praecipuo modo, modulus continuam datam acquisitionem aptam machinae normali operationi exercet, ut gradus vibrationis et condiciones transientes crescens. Waveforms et spectra in modo principali acquisita adhibentur ad outputs procedentes relatos generandos (data extracta). Modus auxiliaris adhibetur ut fluctus formas et spectras magis accuratas in rates renovationes reductas obtineat, modum principalem mensurarum complens. Modus directus adhibetur ad continuam diuturnitatem fluctuum diuturnam obtinendam ex dynamicis input canalibus praecedente eventus terroris, programmata tertiae partis pro notitia visualizationis.

3. Datorum Processing & Analysis

Processus cycli temporum in XMV16 moduli pendent ab spectro (linearum) resolutio ad modos principales et auxiliares mensurae conformatus. Hi cycli processus interni interdum adiuvant ad determinatam ratem ad quam fluctus formas, spectra et notitia extrahuntur ut moduli outputs praesto fiant.

Dum mensurae notitiae ab XMV16 moduli ad datas rates renovationis usque ad 100 ms obtineri possunt, in VibroSight® programmatibus data renovatio est 1 secunda. Hoc significat VibroSight servo capita XMV16 modulorum ad maximum momentum semel per alterum. Exempli gratia, modulus pro 100 ms datae ratee renovationis figuratus in mensura principali modus praebet VibroSight® cum omni decima waveforma, spectro, et notitia extracta affinis.

4. Spectral Data aggregatio

Ad ne damnum potentiale notitiarum magni momenti in notitia mensurae internae XMV16 moduli, aggregatio spectralis notitiarum cacumina in mediis (internis) spectris capiendis adhiberi potest sine insigniter augendo negotiationis retis. Haec aggregatio munus facit apicem-tene data spectris super unam secundam, ut nullas notae culpae transeuntes fallant.

5. Event Deprehensio & Data Logging

Eventus generantur cum valores quoslibet gradus severitatis usoris quinque usoris configurabiles excedunt vel terrores mutationem rate-excedunt. Moles praecellenti notitiae in XMV16 moduli in tabula in tabulatis quiddam memoriae configurabile adhiberi potest et pro notitia certarum praecellentium felis (eventus) notitiarum staticarum usque ad singulas 100 millium secundorum et dynamicorum datarum singulis 1 secundis adhiberi potest. Post-trigger (eventus) notitia statice colligationis ad singulas 100 ms etiam praesto est usque ad 1 horam.

6. Machina publica Deprehensio

Apparatus enuntiat ut onus plenum (onload), velocitate, et transientes deprehenduntur annotando velocitatem referendi contra gradus felis. Hae civitates uti possunt condiciones operativae apparatus software ad mores systematis temperandos. De more, densitas superior logging praesto est secundum condiciones machinae operantis, configurabilis celeritatis et temporis intervalla, vel aliquo alio processu parametri.

7. signum Socius Mechanismum

Intra VM600 Mk2/VM600 tormenta, XMV16 bus Tacho uti potest ad signa tachometer initus communicanda et ad bus rudis ad signa dynamica initus communicanda. Fere, in VM600 Mk2 eculeo (ABE4x), Rudis bus in signis dynamicis initus communicare adhibetur inter processus modulorum, Tacho bus in signis initus inter modulorum processus (ABE4x) initus signa communicare adhibetur, et Open Collector (OC) bus modulorum processus modulorum nullos modulos expellit, omnes intra eundem eculeum.

8. Communicatio & Data Transmissio

Modulus XMV16 communicat cum instrumentis externis currit VibroSight® software via a Gigabit Ethernet interface. Systema communicationis interfaciei (connexiones AETERNET) adhiberi possunt ad nexus/communicationes erigendas inter moduli XMV16 + IO16T et in computers/retis utentes retinacula vexillum Aernet.

Modulus Network Time Protocollum (NTP) utitur pro tempore synchronisationi, quo constantiam temporalem obtinet per systema. AETERNET-panel antica connectens subsidia transmissionis spatia usque ad 100 metra (1000BASE-T obsecundantem) sustinet dum iungo tergo-panel AERNET usque ad 60 metra (1000 Mbps) sustinet. Distantiae enim maximums excedentes specificantur, moduli in notitia translationis redactae agunt.

9. Configurationis & Status Cras

Modulus XMV16 + IO16T plene software-configurabilis per Ethernet est utens programmate computatorio VibroSight®. Modulus plures status indices praebet (LEDs): STATUS et DATA multicolores LEDs indicant XMV16+ IO16T status moduli, ut operatio normalis, status configurationis, vel problemata; AETERNETA connectoris nexus et actio LEDs indicant statum communicationum Aer.

10. Power Management & Thermal Design

Modulus potestatem operantem accipit (+5 VDC et ± 12 VDC) ex copia eculei VM600. Potentia consumptio est <14 W a +5 VDC copia, <8 W a +12 VDC copia, et <4 W ex -12 VDC copia, cum summa potentiarum consummatio <26 W (XMV16 + IO16T moduli). Haec vis efficiens designativa stabilis moduli operationem efficit et dissipationem caloris humilis.



Applications

VM600 XMV16 Vibratio Extensa Module vigilantiae apta est ad sequentes areas applicationes:

  • Rotor Edidit Monitoring & Analysis: Vibratio analysin vigilantia et rotor dynamica pro magnis machinis rotata ut vapores turbines, gas turbines et hydro turbines

  • Rolling Element Analysis supportantes: summus resolutio spectri analysis facultatem ad deprehendendum primo volvens notas culpas afferens

  • Hydro Air-Gap et Flux Cras: subsidia aeris-gap vigilantia et fluxum densitatis magneticae applicationes pro generantibus hydroelectric

  • Industrialis Machinaria Rotating Monitoring: Conditio vigilantia et culpa diagnosis pro machinae gyrationis industrialis ut compressores, fans, soleatus et motores.

  • Praedictiva Sustentatio Systems: Servit ut nucleus componentis plantae predictive systematis sustentationis praebens summus qualitas machinae salutis notitia



Technical Specifications Summary

  • Dynamic Input canales: 16 independens canales

  • Tachometer Input Channels: 4 independent channels

  • ADC Resolutio: 24-bit

  • Maximum Sampling Rate: 98 kHz

  • Dynamic Input Range: -30 ad +30 V (voltage), -25 ad +25 mA (currente)

  • Frequentia Bandwidth: 0.10 Hz ad 38 kHz (AC), DC ad 1.0 Hz (DC)

  • Spectrale Consilium: Usque ad (VI)CD lineae

  • Signo-ad-Noise Ratio: 115 dB (1 kHz bandwidth)

  • Communication Interface: Gigabit Ethernet (1000BASE-T)

  • Temperatura operans: 0 ad 65°C (32 ad 149°F)

  • Virtus Consummatio: <26 W (XMV16 + IO16T moduli)


XMV16 (2)XMV16 (3)XMV16 (4)XMV16 (5)XMV16 (6)XMV16 (7)XMV16 (8).XMV16 (9)XMV16 (10)XMV16 (11)XMV16 (12)XMV16 (13) ;XMV16 (14)XMV16 (15)

XMV16 (16)XMV16 (17)

Previous: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.