The ABB RLM01 PROFIBUS DP/FMS Redundancy Link Module is a high-reliability communication redundancy device designed for industrial automation control systems. This module is primarily used to convert a simple, non-redundant PROFIBUS line into two mutually redundant lines (A and B), significantly enhancing the reliability and fault tolerance of fieldbus communication. The RLM01 is suitable for applications with stringent requirements for system continuity, such as power, chemical, marine, maritime systems, and various process automation control fields.


The RLM01 supports PROFIBUS DP and FMS protocols, with transmission rates ranging from 9.6 kBit/s to 12 MBit/s. It features automatic line selection, communication status monitoring, repeater functionality, redundant power supply support, and fault alarm capabilities. The compact module is designed for easy installation on standard DIN rails and is suitable for various industrial environments.



2. Key Features


Feature CategorySpecific Function Description
Redundancy ConversionConverts one non-redundant PROFIBUS line (M) into two redundant lines (A/B), with bidirectional data transmission
Communication ProtocolSupports PROFIBUS DP/FMS, compliant with DIN 19245 standard
Transmission Rate9.6 kBit/s to 12 MBit/s, configurable via rotary switch
Line SelectionAutomatically detects and selects available lines, supports failover
Monitoring FunctionReal-time monitoring of communication status and errors on all three lines (A, B, M)
Repeater FunctionSignal regeneration capability, supports long-distance communication extension
Power Supply DesignSupports single or redundant 24 VDC power supply, with power monitoring
Alarm OutputProvides potential-free alarm contact for remote fault diagnosis
Installation MethodStandard DIN rail mounting, suitable for industrial cabinets
Environmental AdaptabilityComplies with industrial environment standards, supports marine and maritime applications (GL certified)




3. Functional Description

The RLM01 module features three independent RS 485 interfaces (A, B, M), each supporting full-duplex communication. The module provides electrical isolation between the three interfaces and between the interfaces and the power supply, meeting the VDE 0110 functional isolation standard with a test voltage of 500 Veff.

The module incorporates intelligent line switching logic:

  • When data is received from line A or B with a correct telegram start, it is routed to line M;

  • If line A experiences a telegram start error, the control logic automatically switches to line B;

  • Data received from line M is simultaneously transmitted to both lines A and B, achieving broadcast-style redundant output.

The RLM01 also includes repeater functionality, which reshapes and amplifies received signals, supporting longer-distance PROFIBUS network extension. Each interface can connect up to 31 PROFIBUS stations. When used with repeaters and fiber optic converters, the network scale can be further expanded.



4. Installation and Configuration

Safety Notes

  • Must be powered by safety extra-low voltage (24 VDC); alarm contact power must also comply;

  • According to UL/CSA standards, external protective devices (e.g., fuses, rated 1.6A–10A) are required;

  • Installation location must ensure good heat dissipation, with >30 mm clearance around the module;

  • Do not connect bus lines that are partially or entirely installed outdoors directly to the module; use fiber optics and optical-electrical converters for electrical isolation.

Mechanical Installation

The module is designed for vertical mounting on a 35 mm DIN rail. To install, first place the rear clips on the top edge of the rail, then gently press the bottom of the module until the clips lock audibly. Maintain at least 30 mm clearance above and below the module for heat dissipation.

Electrical Connections

  • PROFIBUS Interfaces: A, B, M are all 9-pin Sub-D female connectors, with pin assignments compliant with PROFIBUS standard:

    • Pins 3, 8: Data positive/negative (RxD/TxD)

    • Pins 5, 6: External termination resistor power (DGND, VP)

  • Power and Alarm Terminals: Use an 8-pin pluggable terminal block for quick replacement:

TerminalDescriptionFunction
1EProtective Earth (PE)
2MPower ground (single supply)
3L1++24 V power positive
4L1+Jumper to L2+ when using single supply
5MRedundant power ground
6L2+Redundant power positive
7F2Potential-free alarm contact (normally closed)
8F1Potential-free alarm contact (normally closed)

Baud Rate Setting

Set the baud rate using the front panel rotary switch, with 10 positions (0–9) as follows:

Switch PositionBaud RateUnit
012MBit/s
16MBit/s
23MBit/s
31.5MBit/s
4500kBit/s
5187.5kBit/s
693.75kBit/s
719.2kBit/s
89.6kBit/s
9No function–

After setting, briefly press the reset button to activate the configuration.



5. Monitoring and Diagnostics

The RLM01 front panel features multi-color LED indicators for communication and power status:

Communication Status LEDs (Act/Err)

  • Yellow Act: Line communication normal (steady or flashing)

  • Red Err: Line communication fault

Power LED (Pwr)

  • Green Pwr: Power normal

  • Off: Power abnormal

Alarm Contact

The module provides a set of potential-free normally closed contacts (F1–F2), which remain closed during normal operation and open in case of communication or power failure, allowing connection to PLC or supervisory systems for remote diagnostics.

Typical Status Indications


Line A Act/ErrLine B Act/ErrAlarm ContactMeaning
Yellow/OffYellow/OffClosedNormal communication on all three lines
Yellow/OffOff/RedOpenNormal communication on A & M only; B faulty
Off/RedYellow/OffOpenNormal communication on B & M only; A faulty
Yellow/YellowOff/OffClosedNormal communication on A & B only; M faulty




6. Application Scenarios

  1. Industrial Process Control: Used in chemical, power, water treatment systems requiring high communication reliability;

  2. Marine & Maritime Systems: GL certified, suitable for ship automation control systems;

  3. Production Line Automation: Supports PROFIBUS DP network redundancy, improves equipment availability;

  4. Energy Management: Suitable for substations, power plants, and other critical infrastructure;

  5. Transportation Automation: Such as tunnel control, railway signaling systems.


ItemSpecification
Serial Interfaces
Number of Interfaces3 (A, B, M)
Interface TypeRS 485, 9-pin Sub-D
Transmission Rate9.6 kBit/s – 12 MBit/s
Electrical IsolationFunctional isolation, 500 Veff
Protection ClassDevice protection class 3
Line Length Limits
Master → M50 m
M → Slave50 m
A/B → A/BAccording to PROFIBUS specification
Data Telegram Delay
A/B → M11 bit times + 0.6 µs
M → A/B4 bit times + 0.6 µs
Power Requirements
Operating Voltage24 VDC (+20 … +33 V)
Power ConsumptionApprox. 150 mA @ 24 V
Power LossApprox. 3.6 W
Connection Terminal8-pin pluggable terminal block
Wire Cross-Section0.14 – 1.5 mm²
Environmental Conditions
Operating Temperature0 … 50°C
Storage Temperature-30 … 85°C
Relative Humidity≤75% non-condensing
Installation Altitude≤2000 m
Alarm Contact
TypePotential-free normally closed contact
Switching Voltage≤60 VDC
Switching Current≤1 A
Mechanical Design
Dimensions (H×W×D)134 × 56 × 70 mm
WeightApprox. 330 g
Mounting MethodDIN 35 mm rail
Protection RatingIP20
Certifications & Standards
North AmericaUL, CSA
EuropeCE (compliant with EMC 2004/108/EC & Low Voltage Directive 2006/95/EC)
Marine CertificationGL (Category A, B, C, D), requires 24 VDC power supply filter
Accessories (to be ordered separately)
PROFIBUS Connectors3 pcs
24 VDC Power Supply Filter1 or 2 pcs (depending on power supply configuration)

Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email: sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.