A9F83216 est 16‑ampere, polus duplicatus (2P) minimus ambitus ruptor e seriei Electrici Schneider Acti9 iC60H, machinata cum charactere curvo (limine magnetico in 4 × In). B‑curva specialiter destinatur pro circuitibus cum minimis incursus concurrentibus - ut inflammatio, onera resistentia, et propositi distributio - ubi praecise oneris tutela est essentialis sine laesione supplantandi. Ut polus fabrica cum utroque polo munito, optime aptus est ad unum tempus AC systemata seu DC applicationes simultaneam disiunctionem utriusque lineae quaerunt, salutem et solitudo auctam offerens. Haec MCB tradit capacitatem aestimavit ultimam fractionis 30 kA ad 220‑240 V AC sub vexillo industriae EN/IEC 60947‑2, et 10 kA ad 400 V AC per norma residentialem EN/IEC 60898‑1, ut robustam culpam intermissionis per amplis applicationibus interrumperet. Utrumque signis certificatum est, faciens eam versatilem electionem pro tabulis distribuendis commercialibus, tabulas dicionis industriae, et incolarum dolorum incolas. Designatur cum Class‑2 insulation pro aucta salute operator, ruptor etiam compagem cum Acti 9 RCDs et Foedus NSX MCCBs coordinat. Cogitatus intuitivorum visiTriporum culpantis fenestrae incorporat, quae statim indicat polum retentus ad accelerandum sollicitudinem, et VisiSafe viridis habena quae confirmatio visualis contactus aperturae haud dubiam tradit — pluma critica ad conservationem operationum. Eius mechanismum vivum fac/creprum, toggle positio independentem, praestans constantem mutandi effectum per 10,000 electrica et 20000 cyclos mechanicos. Cum latitudine 36 mm (vocum modularum 4) et DIN‑rail clip‑on ascendens, spatium usum efficientis in tabulis distribuendis praebet. Cuniculi terminales duplices conductores rigidi accipiunt usque ad 25 mm² et flexibiles usque ad 16 mm² cum 2 N·m torques constringentes. Fabrica defensionem terminalem IP20 et inclusum IP40 praebet, ab -35 °C ad +70 °C fideliter operatur, et cum PVC‑liberis materiis aedificatur, quamquam halogen supra liminum continet. Consequi 54% recyclability rate et totalem vitam cycli carbonis vestigium 28 kg CO₂ eq., hoc MCB adscribit cum proposita Schneider Electrici sustinendi.
Parameter |
Singula |
|---|---|
General |
|
Product Model |
A9F83216 |
Range |
Acti9 |
Product Name |
Acti9 iC60 |
Device Short Name |
iC60H |
Machinam Application |
Distributio |
Polonorum Description |
2P |
Numerus praesidio Poloni |
2 |
Ratum Current (In) |
16 A |
Network Type |
AC / DC |
Iter Unit Technology |
Scelerisque magnetic |
Labi curva |
B |
Magna Tripping Limit |
4 x In ± 20% |
Idoneitatem solitudo |
Ita (conformans EN/IEC 60898‑1 et EN/IEC 60947‑2) |
Utendo Categoria |
Categoria A (EN/IEC 60947‑2) |
Capacitas solvens (Icu) |
|
– LAT/IEC 60947‑2 (AC) |
XXX KA ad CCXX ... CCXL V AC (ex imagine productum, vide plenam datasheet pro aliis voltage ratings) |
– LAT/IEC 60898‑1 (AC) |
10,000 A ad 400 V AC 50/60 Hz |
- DC ratings |
Non certa documenta in provisum |
Service Breaking Capacity (Ics) |
Not specified; vexillum ad seriem datasheet |
Limitatio Classis |
Classis III (EN/IEC 60898‑1) |
Rated Operational intentione (Ue) |
Non explicatio in PDF; innixa serie: typice 12 ... 60 V AC, 100 ... 133 V AC, 220 ... 240 V AC, DC et XII ... 72 V - consulere plena datasheet |
Rated Insulation intentione (Ui) |
500 V AC 50/60 Hz (EN/IEC 60947‑2) |
Rated Impetus resistendi intentione (Uimp) |
6 kV (EN/IEC 60947‑2) |
Network Frequency |
50/60 Hz |
Diuturnitatem |
|
Mechanica Durabilitas |
20000 circuitus |
Electrical Durabilitas |
10,000 circuitus |
Contact Position Indicis |
Ita (toggle) |
Locus significationis |
Iter indicator (VisiTrip) |
Adscendens & Physica |
|
Adscendens Modus |
Clip‑on (35 mm DIN rail) |
Pecten amovibilibus Busbar |
Inauguratus est; compatible summo vel fundo |
Connection Pix |
XVIII mm inter tempora |
Numerus vocum |
4 (36 mm latitudo totalis) |
Latitudo |
36 mm |
Altitudo |
85 mm |
Profundum |
78.5 mm |
Net Pondus |
0.25 kg |
Color |
White (RAL9003) |
Terminationes & Contrahentes |
|
Connection Type |
Unius terminalis (top vel deorsum), duplex cuniculum |
Rigid Conductor (aeris) |
1…25 mm² |
Flexibile Conductor (aeris) |
1…16 mm² |
Flexibile cum Ferrule (aeris) |
1…16 mm² |
Annuli Terminal (Cu / Al) |
Via accessoria |
Filum nudare Longitudo |
XIV mm (top vel fundo) |
tensis Torque |
2 N · m (sursum vel deorsum) |
Terrae ultrices Praesidium |
Separate addendi ad obstructionum requiratur |
Environmental & Praesidium Ratings |
|
Signa Obsequium |
EN/IEC 60947‑2, EN/IEC 60898‑1 |
IP Degree (terminalis) |
IP20 (IEC 60529) |
IP in clausura |
IP40 (Insulation class II) |
Pollutio Degree |
3 (LAT/IEC 60947‑2) |
Categoria Overvoltage |
IV |
Tropicalisation |
2 (IEC 60068‑1) |
Relativum Umor |
95% at 55°C |
Altitude operating |
0…2000 m |
Temperature operating |
-35°C ... +70°C |
Repono Temperature |
-40°C ... +85°C |
Sustineri & Obsequium |
|
Halogenliberum statum |
Product halogen super limina continet (non halogen‑free) |
PVC‑free |
Ita |
Silicone-liberum |
No |
Recyclability Potentia |
54% |
EU RoHS Directivum |
Obsequens |
SPATIUM SVHC |
SVHC super limine continet |
SCIPI Number |
26ff71d1‑98cf‑4280‑8725‑455b9a6b2fb9 |
Packaging cum REDIVIVUS cardboard |
Ita |
Packaging sine unius usu plastica |
Ita |
WEEE Label |
Requiritur ad EU arbitrio (separatum collectio) |
Reparare / Accipe-retro |
No / No |
Logistics |
|
Patria Origin |
Non certa (typically Bulgariam ad seriem iC60) |
Warranty |
XVIII menses |
Sarcina I (Unit) |
1 pc; H 3.5 cm W 7.5 cm L 9.0 cm; pondus 222,4 g * |
Sarcina 2 (box of 6) |
6 unitates; H 8.0 cm W 10.0 cm L 22.5 cm; pondus 1.398 kg |
Sarcina III (Pallet LXVI) |
66 unitates; H 30 cm × W 30 cm × L 40 cm; pondus 15.806 kg |
Carbon Footprint (Lifecycle) |
|
Totalis |
28 kg CO₂ eq. |
Vestibulum (A1‑A3) |
2 kg CO₂ eq. |
Distribution (A4) |
0 kg CO₂ eq. |
Institutionem (A5) |
0 kg CO₂ eq. |
Usus Phase (B2, B3, B4, B6) |
26 kg CO₂ eq. |
End‑of‑vitae (C1‑C4) |
0.7 kg CO₂ eq. |
Environmental Disclosure |
Product Environmental Profile praesto |