sharethis sharing button

Schneider Electric Acti9 iC60N A9F74440 est minimum quattuor polorum ambitus ruptor designatus ad systemata distributionis humilis voltage. 40 A aestimationem defert et in unitatis itinere scelerisque C-characteristico magnetico-magnetico utitur. Ruptor per breve spatium fractionis capacitatem 30 kA ad 220-240 V AC sub EN/IEC 60947-2 et 6,000 A ad 400 V AC sub EN/IEC 60898-1. Apta est institutionibus tam industrialibus quam residentialibus. De fabrica lineamenta duplicis cuniculi terminales, denotat VisiTrip propter culpae locum celeriter, et habena viridis VisiSafe quae contactum foramen ad conservationem tutam confirmat. Eius mechanismum celeriter occlusum, toggle independenter, adiuvat ut vita servitii ad 10.000 electricum et 20000 cyclos mechanicos extendatur. Cum D V AC aestimavit intentionem insulationis, impetum VI kV sustinere, limitationem III Classis, pollutionis gradum III, et categoriam IV overvoltagium, ambitus flagitantes tractat. DIN inpagis 35 mm tondet, octo 9 mm vocum (72 mm latum occupat), et mensurae 85 × 72 × 78,5 mm cum reti ponderis 0,5 kg. Praesidium terminale IP20 praebet (IP40 cum inclusum), ab -35 °C ad +70°C operatur, et in albo venit (RAL9003). Productum cum RoHS et SPATIUM consentit, partes plasticae liberae halogen continet, et 54% recyclability potentialem habet.

Parameter

Singula

Product Model

A9F74440

Range

Acti9

Product Name

Acti9 iC60

Product vel Component Type

Minima circuitus ruptor (MCB)

Device Short Name

iC60N

Device Application

Distributio

Polonorum Description

4P

Numerus praesidio Poloni

4

Ratum Current (In)

40 A

Network Type

AC / DC

Iter Unit Technology

Scelerisque magnetic

Curva Code

C

Capacitas solveret

30 KA ad 220 ... 240 V AC conformes EN/IEC 60947-2
6,000 A ad 400 V AC conformes EN/IEC 60898-1

Rated Insulation intentione (Ui)

500 V AC 50/60 Hz conformis EN/IEC 60947-2

Rated Impetus resistendi intentione (Uimp)

6 kV conformis EN/IEC 60947-2

Limitatio Classis

3 conformes EN/IEC 60898-1

Network Frequency

50/60 Hz

Mechanica Durabilitas

20000 circuitus

Electrical Durabilitas

10,000 circuitus

Contact Position Indicis

Ita

Imperium Type

Toggle

Locus significationis

Iter indicator

Adscendens Modus

Clip-on; removeri pectinem busbar installed

Adscendens Support

35 mm DIN rail

Pecten Busbar et Distributio Clausus Compatibility

Top vel deorsum: Sic

Connection Pix

XVIII mm inter tempora

Numerus 9 mm Pitches

8

Altitudo

85 mm

Latitudo

72 mm

Profundum

78.5 mm

Net Pondus

0.5 kg

Color

White

Terminationes & Contrahentes

Una terminatio (top aut fundum)

Rigid Conductor (aeris)

1…35 mm²

Conductor rigidus (aeris, cum accessoriis)

3 16 mm²

Rigid Conductor (aluminium, cum accessoriis)

1 50 mm²

Flexibile Conductor (aeris)

1…25 mm²

Flexibile cum Ferrule (aeris)

25 mm²

Flexibile (aerarium vel aluminium, cum anulo terminali et accessorie)

1 cable

Flexibile Conductor (aeris, cum accessoriis)

3 10 mm²

Filum nudare Longitudo

XIV mm in vertice aut fundo nexu

tensis Torque

3.5 N · m vertice aut fundo

Terrae-ultrices Praesidium

Separatum obstructionum

Signa

LAT/IEC 60947-2, EN/IEC 60898-1

IP Gradus Praesidium

IP20 conformis IEC 60529
IP40 in clausura modulari (Insulation classis II) conformis IEC 60529

Pollutio Degree

3 conformes EN/IEC 60947-2

Categoria Overvoltage

IV

Tropicalisation

2 conformes ad IEC 60068-1

Relativum Umor

95% at 55 °C

Altitude operating

0…2000 m

Ambiens Aeris Temperature pro Operatione

-35 °C

Ambiens Aeris Temperature pro PRAECLUSIO

-40 °C

Halogen-liber (partes plasticae)

Halogen liberam plastic partes producto

PVC-liber

Ita

Silicone-liber

No

PFAS

Item continet PFAS Chemicals

Recyclability Potentia

54%

EU RoHS Directivum

Obsequens

SPATIUM ordinationem

SVHC super limine continet Reference

SCIPI Number

26ff71d1-98cf-4280-8725-455b9a6b2fb9

Packaging cum Recycled Cardboard

Ita

Packaging sine singulari usu Plastic

Ita

WEEE Label

Requiritur ad EU arbitrio (separatum collectio)

Sarcina I (PCE)

1 pc; H 7.500 cm W 7.200 cm L 9.400 cm; pondus 470.000 g *

Sarcina 2 (BB1)

3 unitates; H 8.000 cm × W 9.800 cm × L 22.500 cm; pondus 1.490 kg

Sarcina III (S03)

33 unitates; H 30.0 cm W 30.0 cm L 40.0 cm; pondus 16.843 kg*

Carbon Footprint - Total

63 kg CO₂ eq.

Carbon Footprint - Vestibulum (A1-A3)

3 kg CO₂ eq.

Carbon Footprint - Distribution (A4)

0.1 kg CO₂ eq.

Carbon Footprint - Installation (A5)

0 kg CO₂ eq.

Carbon Footprint – Usus Phase (B2, B3, B4, B6)

58 kg CO₂ eq.

Carbon Footprint - Finis vitae (C1-C4)

1 kg CO₂ eq.

Environmental Disclosure

Product Environmental Profile praesto

Priora: 
Next: 

Related Products

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.