nyban1
Hic es: Home » Systems » Turbine Imperium » Mark VIe Control System » GE IS200TRPGH1B Gas Turbine Primary Trip Board
Relinque nobis Nuntius

GE IS200TRPGH1B Gas Turbine Prima Trip Board

  • GE

  • IS200TRPGH1B

  • $4300

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

IS200TRPGH1B est a Gas Turbine Tabula Primaria Trip Terminal Board designata Electric Generalis (GE) ad Mark™ VI et Marcum VIum systematum imperium gas turbine. Haec tabula versio est intra seriem TRPG Triplici modulari redundanti (TMR) applicationibus nominatim dedicatis. Praecipuum eius munus est iter mandata accipere a praesidente primario Turbine tutelae (VTUR vel PTUR) et tres Emergency Trip Solenoides (ETDs) per logicam Nullam internam expellere, subitis shutdown praesidiis gasi turbinis fovere. IS200TRPGH1B coniuncta cum tabula TREG operatur latera interfaciei ETD primaria et repentina.


In media linea tabularum IS200TRPGH1B est eius novem tabulae magneticae dispositae, cum tribus mensuris in 2-ex-3 suffragiorum ambitum pro singulis ETD formantibus. Superuacaneum hoc consilium efficit ut, etiamsi una vita nulla deficiat, falsum iter vel defectum scandali non faciat, signanter ratio salutis et constantiae augendae. Tabula etiam initus significationum sustinet ab Geiger-Mueller usque ad octo flammae detectores pro flammae turbine vigilantia.


IS200TRPGH1B versio upgraded H1A est, ut 28 V imperium potestatem et facultatem contactum output melius efficiat. Secundum tabulam comparationem versionis in documento, IS200TRPGH1B has notas habet:

  • TMR applications subsidiis

  • Output contactus support 125 V dc, 1 A et 24 V dc, 3 A

  • Utitur 28 V imperium potestate

  • Apta vexillum applications


Tabulae lineamenta simplex et certa ratio nullis jumpers vel ferramentis uncinis aptandis; omnis configuratione fit per software moderatorem. Connectores JR1, JS1, et JT1 instructi sunt cum ID assulis actoribus tabularum serialem numerum, genus, numerum revisionem et informationes locorum socors, quae ab I/O tabula ad verificationem, ad hardware convenientiam praestandam.



II. Praecipua functiones

Munera primaria IS200TRPGH1B includunt, sed non limitantur ad sequentem:

1. Prima Trinus Praesidium

IS200TRPGH1B tabula mandata itineris accipit ab VTUR vel PTUR moderatore et tres tumultuarios Trinus Solenoides (ETDs) per circulos logicos internos inpellit. Quodlibet ETD regitur per ambitum trium mensium 2-ex-3 suffragiorum composito, dum recta exsecutio mandati itineris etiam si una nulla deficit.

2. 2-ex-of-3 Circuitus Suffragatio

In applicationibus TMR, signa itineris trium moderatorum ferramentis scalae logicae in IS200TRPGH1B adhibitis suffragantur. Respondens ETD utitur tantum cum duo saltem moderatores mandatum iter edunt. Hoc consilium impedit itinera falsa per unum punctum defectum.

3. Nullam Status Cras

In I/O tabula monitores currentis in linea rectoris publici moderandi ad determinandum statum cuiusque Nullam actuosum vel de-energetum. Accedit, quod normaliter unum contactum claudatur ab unaquaque vita in IS200TRPGH1B, a diagnostica circuitione monitorem ad nullam operationem rectam comprobandam. Copia intentionum ad diagnostic usus viverra etiam.

4. flamma Detector Interface

IS200TRPGH1B tabula sustinet signum initibus a Geiger-Mueller usque ad octo flammae detectores. Cum flamma nulla adest, detector mandat usque ad copiam intentionis. Praesentia flammae detector ad solutionem facit, et vis emissa in pulsus voltagenas ab IS200TRPGH1B convertitur. Pulsus frequentia cum vehementia flammae crescit, ab 0 ad 1000 pulsus secundo pervagatus. Hae pulsus intentione ad tres modulos moderatoris incitantur. Pulsat intentione supra 2.5 voltae logicam altam generant, et rate pulsus super 40 ms tempus fenestra calculi mensuratur.

5. Coordinatio cum TREG

IS200TRPGH1B in conjunctione cum tabula TREG, quae subitis systematis velocitatis regitur, operatur. Coniunctio TRPG/TREG tres ETDs agitare potest, cum IS200TRPGH1B tractandis lateris tutelae primariae et TREG lateri tutelae subitis tractandis. Singulis ETD ambitus Oxide Varistor (MOV) metallo includit et resistor currenti limitans ob suppressionem currentem.

6. Hardware id Lepidium sativum

Connectores JR1, JS1, et JT1 in tabula instructi sunt cum tantum ID astulas legere, tabulas seriales numeri, typus, numerus recognitionis et locus slot. Tabula I/O haec informationes legit in initialization. Si mismatch congressus est, ferramentum incompatibilitatis culpa generatur.



III. Systema Applications

1. Application in Marc. VI Systems

Apud Marcum VI systemata, opera IS200TRPGH1B cum tabula VTUR. Tabula VTUR in eculeo VME sita est et ad IS200TRPGH1B per rudentes cum obturaculis fictis coniungit. VTUR munus tutelae primarium itineris praebet, disponens in IS200TRPGH1B disponens ut solenoids principale praesidium praebeat.

2. Applicatio apud Marcum VIe Systems

Apud Marcum VI systemata, IS200TRPGH1B a PTUR I/O sarcinis in tabula TURHIC conscendit. I/O sarcinas obturaculum in connexiones D-type in TURHIC, qui ad IS200TRPGH1B funem est. PTUR munus tutelae iter primariam praebet.

3. Trinus Praesidium Operating Principium

In applicationibus TMR, signa itineris trium moderatorum (R, S, T) suffragantur utens ferramentis scalarum logicarum intra IS200TRPGH1B. Respondens ETD utitur tantum cum duo saltem moderatores mandatum iter edunt. Hoc consilium efficit:

  • Falsa itinera praeventionis: Unius moderatoris defectum vel mandatum adulterinum non faciet iter.

  • Praeventionis Deficio ad Trinus: Unius Nullam nullam non impediet exsecutio mandati iter validi.

  • Princeps Reliability: Systema unum punctum deficiendi tolerare potest, integram tutelam functionality servans.

4. Coordinatio cum TREG

IS200TRPGH1B et TREG tabula simul completam etD coegi interface;

  • IS200TRPGH1B: tractat praesidentiam primariam, a gubernante tutelam primariam Turbine regente.

  • TREG: Handl latus praesidium subitis, ratio subitis moderata moderata.

  • ETD Ambitus: Unusquisque ETD regitur ab utroque IS200TRPGH1B et TREG; a trinus utrobique imperium felis a shutdown.

5. Flamma Cras Application

IS200TRPGH1B signa recipere possunt ab usque ad octo flammae Geiger-Mueller detectores pro flammae turbine vigilantia;

  • Detector signa convertuntur ad pulsus intentione ab IS200TRPGH1B.

  • Frequentia pulsus proportionalis est flammae intensio.

  • Signis pulsus tribus magistrae distribuuntur.

  • Moderatores flammae statum determinant numerando pulsuum intra 40 ms fenestra.



IV. Interface and Operating Principium

1. Nullam Imperium and Status Cras

Singulae tabulae in IS200TRPGH1B a moderatore per I/O tabulam reguntur. Potestatis principium talis est;

  • Coegi Monitoring: I/O tabula monitores currentis in cursoribus publici moderaminis lineam ad statuendos status publici agentis vel de-enervari.

  • Contactus videre: Quisque Nullam praebet contactum normaliter clausum monitorem diagnostica circumscriptionis ad veram operationem nullam comprobandam.

  • Potentia vigilantia: Nullam copiam intentionis ad diagnostica monitoria est.

2. 2-ex-of-3 Circuitus Suffragatio

Unaquaeque ETD regitur per tres mensas (R, S, T moderatores respective) continentes 2-ex-ex-III suffragiorum ambitus;

  • Contactus trium mensarum in certa configuratione conectuntur ad efficiendum logicam ferrariam suffragandi.

  • Circuitus ETD tantum agit, cum saltem duae mensae exercentur.

  • Haec ferramenta suffragandi methodus nullam interventus programmatum requirit, responsio celeria tempora praebet et altam fidem praebet.

3. flamma Detector Interface

Geiger-Mueller operans principium flammae detectores;

  • No Flamma: Detector mandat usque ad 335 V copiam intentione.

  • Flamma Praesens: Detector obit, et energia dimissa in pulsus intentione TRPGH1B convertitur.

  • Pulsus Frequentia: intensionem flammae auget, 0-1000 pulsus range / sec.

  • Signum Processing: Pulsus supra 2.5 V logicae altae agnoscuntur; moderatoris computant pulsus intra fenestram 40 ms.

4. ID Chip Lepidium sativum

Connectores JR1, JS1, et JT1 instructi sunt solum ID xxxiii lege sequentium informationum actarum:

  • Tabula Vide numerum

  • Tabulae genus (IS200TRPGH1B)

  • Revision numerus

  • Locus plug

I/O tabula hanc informationem per satus legit et eam cum valoribus expectatis comparat. Si mismatch congressus est, hardware incompatibilitas culpae generatur, impediens systema problemata ex falsa configuratione causata.



V. Diagnostics et configurationis

1. Functions Diagnostic

I/O tabula probat diagnostica pro IS200TRPGH1B, inter quas:

Diagnostic Item Description
Nullam Coegi videre Monitores Nullam exactoris imperium recta ut quin normalis coegi status
Nullam Contactum videre Monitores re publica Nullam per normaliter clausa contactus
Solenoid Power Bus Monitores suppeditant voltage pro normalis operationem
Flamma Detector Excitatio Voltage Monitores 335 V supplent condiciones pro overvoltage vel undervoltage
ID Chip comprobatio Checks connector ID match, prevents hardware incompatibility

Si signum diagnosticum quodvis aegrotat (ultra limites), terrorem diagnosticam compositum creatum est. Signa diagnostica singillatim palari possunt et reponi cum signo RESET_DIA post reditum ad normalem.

2. Ratio configurationis

IS200TRPGH1B tabulas jumpers vel ferramenta occasus non habet. Omnis conformatio fit per programmatum moderatoris, etiam:

  • Nullam output configuratione logica

  • Detector flamma parametri occasus

  • Diagnostic limina occasus

Hoc consilium simplificat in-site institutionem et sustentationem, difficultates reducendo per unctiones falsas causatas.



VI. Institutionem et sustentationem

1. Adscendens Location

Tabula IS200TRPGH1B typice in tabula terminali bracket insidet intra scrinium imperium gasi turbinis. Apud Marcum VI systemata, coniungit cum VTUR tabulam in VME eculeo per rudentes cum obturaculis fictis. Systemata in Mark VI, cum TURHIC tabula terminali coniungit.

2. Installation cautiones

  • Tabulam subsequens firmiter conscendit et connexiones securi iunguntur.

  • Rudentes recte intitulati sunt ne disiunctio fiat.

  • Exemplar tabularum cognoscere IS200TRPGH1B est, confirmans congruentiam applicationum MR.

  • Reprehendo ID chip informationes in connexionibus systematis configuratione aequet.

3. Sustentacionem Commendatione

  • Periodice connexiones inspicere propter laxationem.

  • Monitor status Nullam et flamma detector signa per systema diagnostica.

  • Si nulla defectio detecta est, confestim integram TRPG tabulam restitue (solutae in tabula singulae non sunt reponendae).

  • Post tabulas reponendas confirmamus informationes ID chip notatas recte agnitas esse et nulla incompatibilitas ferramentorum vitia exstare.

4. replacement De modo procedendi

Salus Admonitiones:

  • MONITUM: Ad impulsum electrica prohibendum, vim pertinentes averte et omnes GE rationes securitatis sequere et exercitia lockout/tagout antequam tabulam reponat.

  • IUDICIUM: Ad ne component damnum electricitatis statice causatum, tabulam cum technicis sensibilibus tractandis tractandis. Praecomprehensio lorum.

Gradus replacement:

  1. Curandi ratio est de-enerized.

  2. Aperi ostium scrinii penes et tabulam IS200TRPGH1B reponendam colloca.

  3. Disiunge omnes rudentes (prima commendatur labella).

  4. Cochleas remove tabulam obtinendam et veterem tabulam eximito.

  5. Instrue novam tabulam et cochleas constringe.

  6. Reconnect omnes funes ut intitulatum.

  7. Potestatem restitue et operationem normalem comprobare novae tabulae per systema diagnosticum.


Item Specification
Exemplar Number IS200TRPGH1B
Product Name Gas Turbine Prima Trip Terminal Board
Compatible Systems Mark™ VI et Mark VIe Gas Turbine Control Systems
Imperium Interface VTUR (Mark VI) vel PTUR.
Dundantia Type Triplex modularis superuacua dicata (TMR)
Numerus Trinus Solenoids 3 (ETD1, ETD2, ETD3).
Nullam per ETD 3 (2-ex-of-3 suffragium)
Total Everyones IX magneticam mensas
Output Contact Rating 1 125 V dc, 1 A .
Output Contact Rating 2 24 V dc, 3 A .
Imperium Power Voltage 28 V: dc (ex JR1, JS1, JT1).
Nullam Coegi Cras Via current in coegi control linea ad determinare ageret/de-energised state
Nullam Status videre Quisque nullam praebet contactum normaliter clausum pro diagnostica vigilantia
Supple intentione Cras Ita, diagnostica proposita
Current suppressio MOV et currens limitans resistor in unoquoque circuitu ETD (in TREG)
Current Economiser Terminationes super TREG ad libitum 10 Ω, 70 W oeconomising resistor
Solenoid Responsio Tempus L / R tempus constant est 0.1 sec
Flamma Detector Type Geiger-Mueller
Numerus flammae Detectors 8
Flamma Detector Supple Voltage 335 V dc
Flamma Detector Supple Current 0,5 mA per detector
Flamma Detector Output signum Pulsus intentionis, pulsus 0-1000/sec
Arteriam logicam pulsum > 2.5 V
Pulsus Counting Fenestra 40 ms
Signum Distributio Intentione pulsus agitator omnium trium modulorum moderatoris
Connectors JR1, JS1, JT1 (cum ID eu)
ID Chip Content Vide numerum, tabula genus, numerus revision, locus obturaculum
Hardware Compatibility Check I/O tabula legit ID chip, culpa generatur in mismatch
Modus configurationis Nullae jumpers, nullae ferrariae occasus; set per software controller
Adscendens Methodus Inclusus in bracket terminali tabulae, coniunctae ad moderatoris eculeum per retinacula
Operans Opera Gradus industrialis, conveniens gas turbine campi ambitus
Testimonia Meets GE Industrial Control Systems standards


Previous: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.