The CA202 piezoelectric accelerometer is one of the core products of the vibro-meter brand under Meggitt, designed specifically for industrial vibration monitoring and measurement. The sensor employs a symmetrical shear-mode polycrystalline piezoelectric sensing element housed in an austenitic stainless steel case, offering excellent mechanical stability and long-term reliability. Model 144-202-000-205 is the standard version equipped with a 3-meter integral low-noise cable, suitable for industrial vibration monitoring in non-hazardous areas.


With its high sensitivity, wide frequency response, strong environmental adaptability, and long-term stability, the CA202 sensor is widely used in vibration monitoring and fault diagnosis systems in industries such as power generation, petrochemical, aerospace, and heavy machinery. Its design complies with multiple international standards and can achieve high-precision vibration signal acquisition and analysis when paired with compatible signal conditioners (e.g., IPC70x series).



2. Key Features & Benefits


FeatureDescription
High Sensitivity100 pC/g, suitable for high-precision measurement of weak vibration signals.
Wide Frequency Response0.5 Hz to 6,000 Hz, covering the vibration frequency range of most industrial equipment.
Wide Operating Temperature RangeThe sensor can operate continuously from -55°C to +260°C, suitable for extreme temperature conditions.
Robust Sealed ConstructionHermetically welded austenitic stainless steel case and flexible stainless steel protection hose, resistant to dust, water, oil, and corrosion.
Symmetrical Differential OutputInternal case insulation with differential signal output for strong noise immunity.
Integral CableLow-noise cable is hermetically welded to the sensor, eliminating connection point failures.
Suitable for Harsh EnvironmentsOptional explosion-proof (Ex) versions for use in potentially explosive atmospheres (Zone 0/1/2).
Easy InstallationStandard M6 mounting holes, no additional insulating washers required, compatible with various mounting adapters.




3. Application Areas

The CA202 accelerometer is suitable for the following industrial vibration monitoring scenarios:

  1. Power Generation Equipment

    • Vibration monitoring of bearings and casings in steam turbines, gas turbines, wind turbines, and hydro generators.

  2. Oil & Gas

    • Vibration analysis and fault prediction for compressors, pumps, fans, and pipelines.

  3. Heavy Machinery & Manufacturing

    • Vibration monitoring of machine tools, stamping equipment, conveyor systems, and metallurgical equipment.

  4. Aerospace & Defense

    • Vibration testing on engine test benches, ground support equipment, and propulsion systems.

  5. Transportation

    • Vibration diagnosis for rail vehicles and marine propulsion systems.

  6. Research & Laboratories

    • Structural dynamics testing, modal analysis, and vibration table control.



4. Ordering Information

The CA202 is available in multiple versions and cable lengths. Below are some example models:

Version TypeCable LengthPart Number (PNR)
Explosion-Proof (Ex)3m144-202-000-106
Explosion-Proof (Ex)6m144-202-000-116
Standard Version3m144-202-000-205
Standard Version6m144-202-000-216
Standard Version11m144-202-000-226
Standard Version20m144-202-000-236

For other cable lengths or special configurations, please contact your local Meggitt representative.



5. Installation & Usage Recommendations

  1. Mounting Orientation: The sensor should be mounted along the measurement axis, with the arrow direction aligned with the vibration direction to ensure a positive signal output.

  2. Mounting Surface: Should be flat and clean; no additional insulating washer is required.

  3. Cable Securing: Avoid excessive bending or strain on the cable; use cable clamps for support.

  4. Signal Conditioning: Must be used with a charge amplifier (e.g., IPC70x) to obtain a voltage signal for data acquisition systems.

  5. Calibration: Dynamically calibrated at the factory (5 g, 120 Hz); generally no recalibration is needed.


6. Recommended Accessories

Accessory NameModelPart Number (PNR)Purpose
Mounting Adapter KitMA133809-133-000-011For CA20x/CE31x series, includes Micaver (mica-glass) thermally isolating base


Table 1: General Specifications

ItemSpecification
Product Linevibro-meter CA202
Example Model144-202-000-205 (Standard Version, 3m cable)
Sensing PrincipleShear-mode piezoelectric effect
Output TypeCharge output (requires charge converter)
Signal Connection2-core shielded cable, insulated from case
Compatible Signal ConditionerIPC70x series charge amplifier

Table 2: Electrical & Dynamic Performance (@23°C)

ParameterValueRemarks
Sensitivity100 pC/g ±5%Calibrated at 120 Hz, 5 g
Dynamic Measurement Range0.01 – 400 g (peak)
Overload Capacity (peak)≤500 g
Linearity Error0.01–20 g: ±1%
20–400 g: ±2%

Transverse Sensitivity≤3%
Resonant Frequency>22 kHz (nominal)
Frequency Response Range0.5 – 6,000 Hz ±5%Lower limit depends on signal conditioner
Insulation Resistance≥10⁹ Ω
Sensor Capacitance (pin-to-pin)5,000 pF
Cable Capacitance (per meter)105 pF (pin-to-pin)
210 pF (pin-to-ground)

Table 3: Environmental Specifications

ParameterSensorIntegral Cable
Continuous Operating Temperature-55°C to +260°C-55°C to +200°C
Short-Term Survival Temperature-70°C to +280°C-62°C to +250°C
Temperature Sensitivity Error-55°C ~ +23°C: 0.25%/°C
+23°C ~ +260°C: 0.1%/°C
Relative to 23°C reference
Protection RatingHermetically welded, resistant to dust, water, oil, salt spray
Case MaterialAustenitic stainless steel (1.4441)
Protection Hose MaterialHeat-resistant stainless steel (1.4541)
Base Strain Sensitivity0.15 × 10⁻³ g/µε (@250 µε peak-to-peak)
Shock Resistance≤1000 g (half sine, 1 ms)

Table 4: Mechanical & Mounting Specifications

ParameterValue
Case MaterialAustenitic stainless steel
Weight (sensor)Approx. 250 g
Weight (cable)Approx. 135 g/m
Mounting Method4×M6×35 Allen screws with spring lock washers
Mounting Torque15 N·m (11.1 lb-ft)
Cable Length (Model 205)3 meters
Cable TypeMTLN-205 (K205A) low-noise shielded cable
Wire ColorsBlue (signal+), White (signal-), Green (case ground)

Table 5: Certifications & Compliance

Certification TypeStandard/Certificate
CE MarkingComplies with EU Directives
EAC MarkingEurasian Customs Union Conformity Certification
Electromagnetic CompatibilityEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011
Electrical SafetyEN 61010-1:2010
Environmental ComplianceRoHS (2011/65/EU)
Explosion-Proof Certification (Optional)ATEX, IECEx, UKEX, cCSAus, etc. (see Ex versions for details)


Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email: sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.