nyban1
Hic es: Home » Systems » Sensus Ratio » VM Piezoelectric Accelerometer » Vibro-Meter CA202 144-202-000-115 Piezoelectric Accelerometer
Relinque nobis Nuntius

loading

Vibro-Meter CA202 144-202-000-115 Piezoelectric Accelerometer

  • VM

  • CA202 144-202-000-115

  • $8600

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

CA202 144-202-000-115 est explosio-probatio versionis mediae longitudinis intra Vibro-Metrum (nunc pars Group Meggitt) CA200 series piezoelectricae accelerometri. Hoc exemplar lineamenta securitatis intrinsecae explosionis-probationis designationis (Ex ia) instructa cum fune VI metri integrali, speciatim ad applicationes industriales destinata, quaerunt medium spatium vibrationis vigilantia in ambitibus explosivis potentia. Cum fabrica salus multis signis globalis certificata, in locis ancipitibus tuto ac fidenter operari potest (Zone 0/1/2) sicut plantae petrochemicae, facilities processus gasi naturalis, et fabricatio pharmaceutica, solutionem securitatis intrinsecam praebens ad conditionem vigilantiam machinae rotationis criticae.


Salvo nucleo technicae commoda seriei CA200, hoc productum stricte adhaeret cum signis explorationis intrinsecae salutis, limitans scintillam electricam et energiam thermarum quae generari ad gradus tutos potest, fundamentaliter praeveniens ignitionem ambientium mixturae gasi explosivae. Funis longitudinis designatio 6-metrium librat institutionem flexibilitatem et oeconomicos wiring, quae spatium requiruntur ad nexus in locis ancipitia maxime sensoriis tuto coniunctio, vitando multiplicitatem et impensas cum rudentibus nimis longis coniungendis auget.


Hoc exemplar non solum vibrationis excellentis sensibilis effectus habet, sed etiam magni ponderis pars systematis vigilantiae completae salutis inservit. Prosequitur multiplicibus certificationibus requisitis inter ATEX Directivas 2014/34/EU, IECEx signis internationalibus et cCSAus Americanus Septentrionalis signa, praebens utentes facilioribus et certis technicis cautionibus ad applicationes ancipitia area per orbem terrarum.

2. Core Design Features and Salutis Commoda

2.1 Intrinsic Safety Explosion-Proof Design

  • Praesidium amplissimum explosionis: Features Ex ia consilio salutis intrinsecae, aptas gasis ambitus in Zonis 0, 1, et 2, praebens dual-culpam salutis tutelam.

  • Adaptabilitas latitudinis Gas Group: Certificata est Group IIC, tuto adhiberi potest in ambitibus gasorum perurbanissimis inclusis hydrogenii et acetylene.

  • Lata Temperature Range Certification: Temperature classes T6 ad T2 operiunt, accommodans temperaturae ambitus operandi ab -55°C ad +260°C

2.2 praerupta Industrial Grade Construction

  • Structura plene signata: Sensor habitationi et funiculi caligarum austenitico inactu ferro confecto (1.4441) et calore repugnanti ferro immaculato (1.4541), integram rimam-probationem unitatis per glutino hermeticam efformans.

  • Praeclara Environmental Adaptabilitas: Praesidium campester aequivalens IP68, resistens humiditati C%, aquae, vaporis, olei contagione, salis asperi, et aliae ambitus industriae durae exesa.

  • Princeps Mechanica Fortitudo: Possibile sustinere 1000g onera impulsum, operandi stabilem praestandi in ambitus vibrationis graves

2.3 Superior Electrical Performance

  • Summus Sensibilitas Mensurae: Sensus Sensus 100 pC/g, cum consilio sono humili coniuncto, vibrationes accurate capere potest ab infirmis ad severum.

  • Lata Frequentia Responsio: Frequentia amplitudo 0,5 Hz ad 6 kHz, notae vibrationis frequentiis machinae industrialis maxime obtegentes

  • Integra Electrical Isolatio: Universa Nulla inter signum terminales et habitationem, Nulla resistentia ≥1×10⁹Ω, efficaciter impedit humus loop impedimentum

2.4 Global Certification System

  • ATEX Certification: LCIE 02 ATEX 6179 X

  • International IECEx Certification: IECEx LCI 10.0018X

  • North American cCSAus Certification: 70004630 (Class I, Division 2, Groups AD & Zonam 2)

  • Aliae Certificationes Regionales: UK Complectens UKEX, Russian EAC, et aliae certificationes nationales

3. Typicam Application Areas

3.1 Oleum & Gas Industry

  • Suboles Platforms & FPSOs: Vibratio vigilantia armorum criticorum ut potentiae generationis principalis, compressores processus olei/gas, et aquae iniectio soleatus

  • Onshore Oil & Gas Processing Plants: Motuosa armorum rotating ad stationes compressor gas naturales, facultatem LNG, et unitates desulfurization/decarbonizationis

  • Exacutio & petrochemical Unitates: Reactor pascuntur soleatus, gas redivivus compressores in catalytic rimas, hydroprocessing, et ethylene crepuerunt unitates.

3.2 Chemical & Pharmaceutical Industry

  • Unitates chemica Reactio: Reactor agitationis systemata, atomi, et dryers ad solventes flammabiles (alcoholae, ketones, hydrocarbonum aromaticum)

  • Solvendo Recovery Systems: distillationis columnae soleatus pascere, antliae vacuum, et compressores transferre solvendo

  • Spraying & Coating Workshops: evacuationis systematis fans, machinas exhauriendi, et materiam transferendi soleatus

3.3 Energy & Utilitas

  • Gas-accensus Power Plantarum: Gas turbines et systemata auxiliares in locis in quibus vapores combustibiles cumulare possunt

  • Coal Gasification & Syngas Unitates: Pascite compressores gasi, syngas circulatores, et apparatum separationis cryogenic.

  • Biogas & Biomass Power Generation: Gas pretreatment systems et boosting/translatio armorum

3.4 Alii Periculosam Area Applications

  • Frumentum Processing & Feed Productio: Critica apparatu rotating in pulvere explosione-protected areis (pulvis explosio applicability indiget confirmatione)

  • Aerospace fuel Testis: Aviation fuel pumps and fuel system test scamna

  • Proprium Material Productio: Processus apparatu involvente flammabiles gas rudis materiae

4. Ratio Integration & Salutis instruitur Guide

4.1 Intrinsic Salutis Loop Architecture

Ratio Design Requisita:
  1. Ansam integritas: forma intrinseca salus ansa

  2. Parameter Matching: Sensor salutem parametri esse compatible cum salute obice parametri

  3. Systema Certification: omnes adiuncti instrumenti debent habere correspondentes explosiones probationum certificationum

4.2 Pre-Installation Praeparatio

4.2.1 Salutis Assessment

  • Adfirmare ancipitia area genus (Zonam 0/1/2) institutionis locus

  • COGNOSCO genus et coetus de explosive gasorum

  • Assident impulsum ambientium temperatus temperatus in classe

4.2.2 Parameter Verification

  • Impetra CA202-115 explosionis probationis libellum ac salutem parametri (Ui, Ii, Pi, Ci, Li)

  • Lego compatibilis saluti obice: Uo≤Ui, Io≤Ii, Po≤Pi, Ccable+Ci≤Co, Lcable+Li≤Lo

  • Praestare scriptum loop rationes et archivum

4.3 De-Site instruitur gradibus

4.3.1 sensorem Mechanica instruitur

  1. Superficies Praeparatio: Mundus superficies ascendens, idoneus efficiat ≤0.01mm

  2. Positiones & EXERCITATIO: Positiones et exercitio 4×M6 foramina ascendentium per extractionem, 20mm profundum, sonum profundum 14mm.

  3. Adscendens & Fixing: Usus M6×35 cochleis cum lavatoribus vernis, appone filum LOCTITE 241 compositum densis

  4. Torque Control: clavis torque torque, obstringere in transversalis serie ad 15 N·m

4.3.2 Cable Routing (Intus Periculosam Area)

  1. Iter congue: Lego viam brevissimam et tutissimam, fuge anfractibus acutis

  2. Flectere Radius: Subsequere funem minimum ≥50mm flexuram radii (static)

  3. Fixation Spacing: Utere fibulis ferro immaculatis, singulis figere 1-1.5 metra

  4. Accentus Relevamen: Providere servitium ora sagi ad exitus sensorem et confluentes archa viscus puncta

  5. Separatio Requisita: Pone ≥50mm separationem inter funes IS et retinacula potentia, transire ad 90° angulum cum opus est.

4.3.3 Electrical Connection

  1. Adiunctae cistae electae: Coniunctiones scriniorum cum congruis explosionis probationis aestimatione (Ex d, Ex e, etc.)

  2. Terminatio Connection: Iungo rubra/signa fila alba ad SIG+/SIG-, scutum manubrium secundum principium unicum punctum grounding

  3. Tutela signantes: Utere glandulis explosione-probationis cables ut coniunctas buxum signantes integritatem

  4. Patet Lepidium sativum: Omnia loramenta habeant caeruleo agnitio seu pittacia

4.4 Tutus Area Interface

  1. Salus Obex instruitur: Instrue in tutum area vel in Zona 2 explosione-probationis repositoria

  2. Curatio grounding: IS ansa scutum ex uno puncto in tuto obice

  3. Systema Connection: Safety obice output connexum cum signo conditioner et ratio vigilantia

5. Sustentacionem, Inspectionem & Salutis Obsequium

5,1 regularis sustentationem Morbi rhoncus

5.1.1 Daily SCUTULATUM

  • Visual inspectio sensoris et funis species integritatis

  • Adfirmare ascendens fasteners non solutam

  • Reprehendo funem caligarum ad lapsum vel deformatio

5.1.2 Quarterly SCUTULATUM

  • Reprehendo confluentes buxum signationem perficiendi

  • Quin ratio integritas præcomprehensio

  • Nulla resistentia metimur loop

5.1.3 Genus SCUTULATUM

  • Comprehensive CREPITUS-probatio integritas reprehendo

  • Calibration verificationem (si opus fuerit)

  • Renova incolumem documenta monumentis

5.2 Culpa Diagnosis & Handling

5.2.1 Commune Fault Phaenomena

  1. Signum Damnum: Reprehendo potentia copia, munimentum salutis, rhoncus tincidunt

  2. Nimio sonitus: Reprehendo grounding, protegens, funem routing

  3. Signum Drift: Reprehendo temperatus effectus, conscendens accentus

5.2.2 Principia Salutis Tractantem

  • Culpa diagnosis de area tutum prioritize

  • Opus in ancipitia areis peragenda sub labore permiserit

  • Reparationibus involventem salutem loramenta intrinseca facienda sunt per personas habiles

5.3 Praecipua Safety Requirements

5.3.1 'X' Speciales conditiones pro Usus
Hoc libellum explosio-probationis exemplaris fert 'X' notationem, condiciones speciales ad usum significans:

  • Ambiens Temperaturae Limitationes: arcte adhaerere debent necessitudini inter genus temperatum et temperatum ambientem

  • Institutionem Curatores Qualification: instituatur et servetur per idonei personas exercitatos in explosione tutelae

  • Documenta Integritas: Usor debet habere plenam explosionis probationem certificatorium et technica documenta

5.3.2 Repair limitationes

  • Users prohibentur disassemble corpus sensorem

  • Modificare funem longitudinis seu structurae on-site prohibetur

  • Reparatione operis reddi debet ad fabrica vel auctoritate muneris centrum

5.4 Documenta Management

Technical Documenta servanda:

  1. Product explosion-probationem absolute certificatorium et annexis

  2. Intrinseca salus ansa calculi iaculis

  3. Installation drawings and wiring diagrams

  4. Calibration libellorum et testium tradit

  5. Tutela monumenta et reficere tradit

6. Technical Commoda Summary

6.1 Safety Reliability

  • Plures global explosione-probationis certificationum salutem in ancipitia area applicationes

  • Intrinseca salus consilium summis explosionis praesidiis praebet

  • Consignatus iuncta compages efficit diuturnum tempus environmental resistentia

6.2 Technical Progressio

  • Lata temperatura range operandi facultatem, ambitus extremas accommodat

  • Summus praecisio vibrationis mensurae, apparatum accurate praebet conditio data

  • Complete EMC consilio, fortis anti-impedimento facultatem

6.3 Usability Economic

  • 6-meter cable longitudo optimizes institutionem sumptus et flexibilitatem

  • Liberum consilium sustentationem reducitur totalis sumptus lifecycle

  • Global certificationes reducere project obsequio sumptibus et tempore

6.4 Ratio Compatibility

  • Compatible cum Meggitt est plena range salutis claustra et vigilantia systemata

  • Vexillum signum output, facilis integratio in systematibus existentibus

  • Praebet completum technica auxilium et applicationem ductu

7. Ordinare Information & Support

7.1 Product configurationis

  • Basic Model: CA202 Ex ia Version

  • Cable Longitudo: 6-meter integer

  • Connexio Methodi: Volans plumbum terminals

  • Latin Accessories: Adscendens Cochleas, washers, libellum calibratiis

7.2 Accessories libitum

  • Adscendens brackets et scelerisque rhoncus nulla (MA133)

  • Explosio-probatio juncturas pixides et glandulas funes

  • Claustra salutis dedicavit signumque conditioners

7.3 Support

  • Praebere explosionis probationem applicationis consultationem et ansam consilio directionis

  • In-site institutionem directionis ac technicae disciplinae

  • Post-sales officium responsive network

7.4 Declaratio magna

Productum hoc utendum est secundum requisita certitudinum explosionis. Quamlibet institutionem et usum qui normis non obtemperaverit, certificationem explosionis probationis infirmabit et casus graves securitatis causare potest. Priusquam seligantur et instituant, utentes diligenter perlegant documenta technica et cum necesse est peritis technicis explosionem probationis fabricantis consulant.


Technical Parameter Categoria Specific Parameter Specification Test Conditions & Description
Basic Product Information Product Model CA202 (Ex ia Explosion-Probatur) Meggitt vibro-meter Series

Ordo Number 144-202-000-115 Explosion-Probatio Version, 6m Cable Longitudo

CREPITUS-Probatur Level Ex ia IIC T6...T2 Ga Salus intrinseca, Pro Gas Environments

Locum Zona Zona 0, 1, 2 (Gas) Adhiberi possunt in Zona 0, 1, et 2
Morbi laoreet euismod Sensibilitas 100 pC/g±5% @23°C, 120Hz, 5g Peak

Mensuratio dolor 0.01-400 g (cacumen) Linearibus Operating dolor

Overload Capacity 500 g (Peak) Transiens Impact Tolerantia

Linearity ±1% (0.01-20g Pecco)
±2% (20-400g Pecco)
CENTESIMA plena Scale

Sensitivum transversum ≤3%

Resonant Frequency >22 kHz (Mounted) Typical Value

Frequency Responsio 0.5 Hz-6 kHz (±5%) Plana Responsio Range

Nulla Resistentia ≥1×10⁹ Ω Signum Terminatio ad Praesent

Parameters capacitatem Sensoris Corpus:
Pole-Poli: ~ 5000 pF
Pertica: ~10 pF
Cable Distribution (per meter):
Pole-Poli: ~105 pF/m
Pertica: ~210 pF/m
Critica Parametri ad Intrinsicam Safety Loop Calculation
Environmental & structural Parameters Operating Temperature Sensor: -55°C ad +260°C
Cable: -55°C ad +200°C
Continua Operating Temperature

Repono Temperature Sensor: -70°C ad +280°C
Cable: -62°C ad +250°C
Non-Operans Condition

Temperature Coefficient -55 ad +23°C: 0.25%/°C
+23 ad +260°C: 0.1%/°C
Sensibilitas Mutare Ad XXIII ° C *

Praesidium Level IP68 Equivalent Plene iuncta structura signati

Repugnantia inpulsa 1000 g (Piccus) Sinus unda, 1ms

Material Structure Housing: Austenitic Steel 1.4441
Hose: Calor-Repugnans Steel 1.4541
Hermetically iuncta
Electrical Safety Parameters Maximum Input intentione (Ui) Quaere explosio-Probatur Quisque Safety Loop Parameter

Maximum Input Current (II) Quaere explosio-Probatur Quisque Safety Loop Parameter

Maximum Input Power (Pi) Quaere explosio-Probatur Quisque Safety Loop Parameter

Capacitance Internum (Ci) ~5000 pF Safety Loop Parameter

Internum Inductance (Li) Negligens (≤1 μH) Safety Loop Parameter
Mechanica & Adscendens Parameters Pondus Sensor: ~250g
Cable: ~135g/m


Cable Longitudo 6 Meters Integral Steel Hose Cable

Adscendens Methodus 4×M6×35 Socket Head Cap Cochleas
4×M6 Ver Lock Washers
Torque: 15 N·m
Nulla Nulla eget adscendens Superficies

Electrical Connection Volans Plumbum Terminals Red / White signum filis et scutum
Certificaciones & Calibration FRAGOR-Probatur certificaciones ATEX: LCIE 02 ATEX 6179 X
IECEx: IECEx LCI 10.0018X
cCSAus: 70004630
UKEX: CML 22 UKEX 2746 X
Cum 'X' Special Conditions for Use

Aliae certificaciones EMC: EN 61000-6-2/-6-4
Salutis: EN 61010-1
Environmental: RoHS (2011/65/EU)


Calibration Factory Dynamic Calibration @5g Pecco, 120Hz, 23°C Calibration Quisque dummodo

CA202 (4)

Previous: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.