nyban1
Hic es: Home » Systems » Turbine Imperium » Mark VI » GE IS200TAMBH1ACB Acoustic Monitoring Terminal Board
Relinque nobis Nuntius

GE IS200TAMBH1ACB Acoustic Cras Terminal Board

  • GE

  • IS200TAMBH1ACB

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

IS200TAMBH1ACB est acusticus Monitoring Tabula Terminalis (TAMB ) ab GE Energy fabricata ut pars systematis ditionis Mark VI turbinibus. Haec tabula terminalis designata est interfaciendi cum VAMB (Acoustic Monitoring I/O sub‑assembly) ut signum praebeat condiciones sensoriis dynamicae pressionis adhibitae in vigilantia combustionis turbine gasi. TAMB sustinet usque ad novem canales signi acoustici initus per tabulas, et usque ad duas tabulas TAMB uni VAMB coniungi potest, cum totalem 18 canales dynamicorum combustorum vigilantium (flammae detectionis et pulsus pressurae) in GE compages 6, 7, vel 9 turbines gasorum.

IS200TAMBH1ACB millivolorum incursus e tertia parte criminis amplificatores vel sensores a venditoribus acceptis, ut Bentley Nevada®, Vibro‑meter®, PCB Piezotronics®, GE Praepositus Systematis Virtutis Converter Signum Amplificantis (CCSA), et GE/Reuter‑Stokes®. Tabula potentiarum flexibilium praebet copiam optionum sensoriis, incluso currente limitato +24 V dc et ‑24 V dc outputs, necnon fons constantis currentis (4 mA) pro certis generibus sensoriis. Singulis canalibus includuntur jumpers configurabiles ad eligendum intentionem vel inputationem currentem, et ad ligationem reditus lineae ad potentiam communem vel ad fluitantem relinquendum. Tabula etiam lineamenta BNC outputs opponit pro singulis canalibus, directa vigilantia dynamici pressionis signo dato (cum DC bias remoto).

TAMB in Turbine scrinium imperium annectitur et cum tabula VAMB (in I/O eculeo posita) per 37‑pinum funem coniungit. Tabula non habet LEDs vel fuses; diagnostica per VAMB et Mark VI systema temperantia relata sunt. IS200TAMBH1ACB simplex (non‑redundans) est tabula terminalis et ad usum solum in conformationibus simplicibus destinatur. Suffixum ACB revisionem specificam indicat cum varia variatione membranarum vel componentium cum prioribus versionibus comparatae, sed plene retrorsum compatitur cum omnibus applicationibus TAMB existentibus.

Eget Description

Munus vigilantia acoustica critica est ad instabilitates combustionis detegendas (exempli gratia, strigis, murmuri, vel aliorum pressionum fluctuationes) in combustores turbine gas. IS200TAMBH1ACB novem canales praebet conditionis signatae (expandabiles ad 18 cum tabula secunda) cum sequentibus facultatibus:

  • Inputationes differentiales cum lucro congruo (1, 2, 4, vel 8) ad optimize signum solutionis.

  • Fast synchronum sampling cum 8x super‑sampling ad minimize analog eliquare.

  • Deprehensio filum apertum per impedimentum altae DC biae quae ad +28 V, 28 V vel humum apponi potest.

  • Firmamentum est tam intentione quam currenti (4‑20 mA) modi initus in via ferramentorum jumpers.

  • Potentia copia criminis externae augentium: quilibet canalis praebet currente limitato +24 V et 24 V output, plus constantem currentem (4 mA) fontem selectabilem per VAMB.

  • Buffered BNC output pro quolibet canali (signo minus DC bias) pro magna vel sollicitudine externa.

  • Vide EPROM ad tabulas identificatio (typum, revisionem, numerum Vide, et locum connectoris) quod a VAMB pro hardware verificationis legitur.

TAMB mV‑gradu signum differentiale accipit a sensore vel crimine amplificante. Coniugatio differentialis constat ex SIGx (signo) et RETx. Tabula suppressionem transientem electromagneticam praebet et signum conditionatum transit ad VAMB per 37‑pinum connectoris (JA1 vel JB1). VAMB conversionem analogam‑to‑digitalem facit, DC bias amotionis, RMS calculi, Fast Fourieriani Transform (FFT), et terrorem deprehendendi.

Hardware Characteres

Forma corporis factor et adscendens

IS200TAMBH1ACB est tabula impressa wiring disposita ad inscendendum in arca potestate Mark VI. XLVIII‑pinum cuspis clausus terminalis (TB1/TB2), duos 37‑pinos D‑sub connexiones (JA1 et JB1) habet pro connexione cum VAMB, et novem connexiones BNC (BNC1 per BNC9) pro outputs buffered. Tabula ex VAMB per 37‑pinum funem posita est; separatum initus non requiritur potentia.

Connectors et Terminals

Connector / Terminal

Type

Descriptio

TB1/TB2 (fibulae summa 48);

Euro-style terminalis obstructionum

Consuetudo ager wiring pro 9 canalibus: quilibet alveus paxillos habet pro P24V, N24V, SIG, RET et PCOM. Etiam DIAG, DIAGRET, SCOM.

JA1

37‑pin D‑sub femina

Tabulam coniungit VAMB (prima interface ad canales 1‑9).

JB1

37‑pin D‑sub femina

Ad secundam TAMB tabulam coniungit (cum 18 canales requiruntur) vel insueta permanet.

BNC1 ad BNC9

BNC femina (panel antica)

Buffered output per channel: Signum post DC bias remotionis, lucrum = 1, 40 Ω output impedimentum.

Terminatio Point Definitiones (partiales - 48 fibulae)

Signum nomen

Pin #

Descriptio

PCOM

1, 6, 11, 16, 25, 30, 35, 40, 45;

Potentiae copia pro P24V vel N24V supplet.

P24V1

2

+24 V output (current‑limited) pro canali 1 crimen amplians.

SIG1

3

Signum differentiale input (positivum) pro canalis 1 .

N24V1

4

-24 V output (current‑limited) pro canali 1 (usus est cum Bentley‑Nevada).

RET1

5

Reditus differentialis initus pro canalis 1 .

... (similiter pro canalibus 2‑9).

...

...

DIAG

46

Diagnostic DAC output ex VAMB.

DIAGRET

47

Redi pro diagnostico DAC output.

SCOM

48

Clypeo loco, for cable, obumbratio.

Jumpers

Quisque canalis duos jumpers habet:

DESULTOR

Type

Munus

JP2, JP4, JP6, JP8, JP10, JP12, JP14, JP16, JP18;

3‑pin thorax (I_IN / V_IN)

Praesens initus eligit (cum 250 Ω onere resistor) vel intentione initus.

JP1, JP3, JP5, JP7, JP9, JP11, JP13, JP15, JP17 (impar numeri)

3‑pin thoracem laneum (PATIO / PCOM)

Coniungit RETx cum PCOM (humi) vel natantem relinquit (OPEN).

Bias Imperium

TAMB permittit VAMB applicari intentionem DC biantis signo et lineas reddere ad deprehensionem apertam. Praeiudicia duobus TTL significationibus per canalem (BIASP et BIASN) regitur ab VAMB;

BIASP

BIASN

Proventus

Falsus

Falsus

No bias; SIGx et RETx trahi ad terram.

Falsus

Verum

-28 v, Praeiudicia adhibenda.

Verum

Falsus

+ 28 Praeiudicia adhibenda v.

Verum

Verum

Illegalis (brevis ambitus prohibet).

Constant Current Selecta

Sensoriis enim constantem fontem (eg, PCB Piezotronicum requirunt), VAMB signum CCSELx (TTL altum) asserere potest, ut 4 mA constantem fontem currentem in linea P24V efficere possit. Hoc loco adhibita est copia intentionis finitae.

Configurationis et Setup

IS200TAMBH1ACB processus in tabulas nullos vel firmware figurabiles habet; omnis figuratio perficitur per tabulas VAMB instrumentorum instrumentorum instrumentorum instrumentorum ad instrumentorum instrumentorum communicationis socialis. Clavis configuratione parametri per alveum include:

  • InputUse - Selecta sensorem (Bently‑Nevada, Vibro‑meter, CCSA, PCB, GE/Reuter‑Stokes, Consuetudo, seu Tabularium).

  • Lucrum - Ferramenta lucra ponit (1, 2, 4, aut 8) ad satietatem vitandam.

  • Low_Input / High_Input - definit conversionem millivolt range ad ipsum unitatis conversionem.

  • Low_Value / High_Value - Definiens unitatum correspondentium ipsum (eg, psi).

  • CCSel - dat constantem modum currentis (Verum/Falsum).

  • BiasLevel - Prospectus DC bias ponit detectionis ambitum apertam (cum InputUse = Custom).

  • SysLimit1 / SysLimit2 - Configurable high/low limites for terror generation.

  • DiagOCChk, DiagBiasNull, DiagSigSat - Admitte/disable specifica diagnostica.

Hardware jumpers apponi debent secundum rationem sensorem et methodum wiring (3‑filum vel 4‑ filum). Documentum mensam singillatim (infra expressam) pro locis laneis praebet:

Vendor

Exemplar

Wiring

JPn (impar)

JPn.

Bentleii Nevada

350500

3‑filum

PCOM

V_IN

Bentleii Nevada

350500

4‑filum

PRINCIPIO

V_IN

Vibro‑meter

IPC 620/704 cum GSI 122/130

3‑filum

PCOM

V_IN

Vibro‑meter

IPC 620/704 cum GSI 122/130

4‑filum

PRINCIPIO

V_IN

GE CCSA

-

-

PRINCIPIO

V_IN

PCB Piezotronics

111A21, etc.

-

PCOM

V_IN

GE/Reuter‑Stokes

Flamma Tracker RS‑FS

-

PCOM

I_IN

Diagnostics et terret

Tabula TAMB non habet LEDs on-tabula. Diagnostica ab VAMB nuntiata sunt sicut tabulae planae et terrores canalis. Communes terrores includunt:

Culpa Code

Descriptio

Potest causa

18‑21

Recta J3/J4/J6/J7 tabula terminalis ID

TAMB cable not connecti, malum TAMB, vel tabula defectiva.

41‑58

Sig x: Open Ckt Test Deficio

Circulus apertus in wiring sensorem vel defectum sensorem.

61‑78

Sig x: Bias Nulling Error

D. Praeiudicia extra ordinem ad delectum sensorem type; InputUse configuratione reprehendo.

81‑98

Sig x: Input signum Saturated

Signum superat X V post quaestum; minuere Lucrum vel reprehendo sensorem.

101‑118

Sig x: Sensor Limit Exceeded

Apicem voltage modum excedit ad genus sensorem delecti.

Etiam VAMB tres tabellas anteriores praebet:

  • Viridis - Micans indicat normalem RUN.

  • Red - Solidus indicat FAIL.

  • Orange - Stabilis indicat terror diagnostica existit.

Installation ac replacement procedendi

Cautiones tractantem

  • Sensus stati - IS200TAMBH1ACB continet elementa static‑sensitiva (EPROM, jumpers, etc.). Semper carpum lorum iacientes gerunt et tabulam tractant in opera fundata.

  • Deenergise ante tractantem – Averte potestatem ad I/O eculeum et tabulam VAMB ante funes coniungendi vel disiungendi ad TAMB.

  • Noli inserere vel removere cum potentia adhibita – vel tabulam VAMB laedat.

Installation gradibus

  1. Ascende TAMB tabulam in gazophylacio moderante utens provisis adscendentibus foraminibus.

  2. Vinculum 37‑pinum ab VAMB (J3 vel J4) ad iungo TAMB JA1 (pro canalibus 1‑9). Si altera TAMB pro canalibus 10‑18 utatur, coniunge funem alterum ab VAMB J6 vel J7 ad alterum TAMB JA1.

  3. Pone jumpers (JP1‑JP18) secundum genus sensorem et methodum wiring (refer ad mensam thoracem laneum).

  4. Filum sensoriis campi ad stipitem terminalem 48‑pin (TB1/TB2), punctis terminalibus opportunis utens (P24Vx, N24Vx, SIGx, RETx, PCOM).

  5. Scutum humum coniunge ad SCOM (pin 48) si opus est.

  6. Coniungere buffered BNC outputs ad apparatum vigilantiam, si opus fuerit.

  7. Potestatem ad VAMB applicare et cognoscere quod fulgura viridis DUXERIT et nullae terrores in diagnostico instrumentorum instrumentorum appareant.

replacement De modo procedendi

  1. Deenergise VAMB et I/O eculeum.

  2. Label et omnes funes ab TAMB disiungunt (37‑pin, BNC, et ager wiring).

  3. Aufer tabulam ab inscensu suo.

  4. Pone jumpers in nova IS200TAMBH1ACB perinde ac in veteri tabula.

  5. Ascende novam tabulam et omnes rudentes reconnect.

  6. Potestatem restitue et operationem cognoscere per ToolboxST.

Informationes iussis

Cum IS200TAMBH1ACB disponens, utere numero partium completarum prorsus ut ostensum est. Pars numerus sequitur conventionem GE:

  • IS200 - Innovation Series, 200‑class.

  • TAMB – Munus acronym: Acoustic Cras Terminal Board.

  • H1 - Generation/version.

  • A - Basi designator.

  • C – Modifier (eg, coating or component variation).

  • B - Revision.

Warranty and Order Placement

  • Warantum supplementum (intra tempus warantum): Contactus GE Energy Post Sales Service (contacta singula per petitionem omissa).

  • Parce partes vel ordines non warantum : Contact GE Sales vel officium tuum proximum. Provide:

    • Pars numerus completus: IS200TAMBH1ACB

    • Turbine imperium systema Vide numerum

    • Materia List (ML) numerus

Nota: omnes digiti et litterae in parte numeri significantes. GE emendationes compatibiles postea substituere possunt, sed retro congruentia confirmata est.

Specification Categoria

Singula

Exemplar Number

IS200TAMBH1ACB

Product Series

Mark VI™ Turbine Control System

Functional Acronym

TAMB - Acoustic Cras Terminal Board

Numerus canalium

9 per tabulam (usque ad 2 tabulas per VAMB = 18 total)

Input Type

Voltatio differentialis (mV) seu currentis (4‑20 mA cum 250 Ω onere)

Supported Sensor Vendolius

Bentley‑Nevada, Vibro‑meter, PCB Piezotronics, GE CCSA, GE/Reuter‑Stokes

Power outputs per Channel

+24 V dc (current‑limitatum, 44 mA typicum, 20‑60 mA cacumen), -24 V dc (20 mA nominale, 30 mA max), et constans current 3.5 mA (selectable)

Potentia Supple Voltage Range

P24V: +22.8 ad +25.2 V (modus modus currentis), +20 ad +30 V (modus assiduus); N24V: -18.85 ad -26 V dc

Input Impedimentum

Modus intentionis: > 1 MΩ; Current modus: 250 Ω (per thoracem laneum)

Optiones quaestus

1, 2, 4, 8;

Maximum potenti signum (post quaestum)

Gain 1: 10 V pk; Lucrum 2, 5 v; Lucrum 4: 2.5 V; Lucrum 8: 1.25 V

Sagaciter (RMS)

± 2.0% of magnitudine (pro aliquo quaestum occasum)

Sagaciter (FFT peak‑to‑peak)

±0.5% magnitudine plena (0‑1600 Hz); ±1.5% (1601‑3200 Hz)

Buffered BNC Output

DG lucrum = 1±0.5%, offset ≤ 30 mV±10%, output impedimentum 40 Ω±50%

DESULTOR Electiones

9× pro I_IN/V_IN; 9× (impar) pro PRINCIPIO/PCOM

Bias Imperium

± 28 V vel humus, per TTL signale e VAMB .

Constant Current Selecta

TTL altum dat venam 4 mA constantem in P24Vx

Open Circuit Detection

Ita, per DC biam ac vigilantiam signi campi

Diagnostics

Circuitus apertus, inclitus error irritus, satietatem insigne, modus sensoris excessit, ratio limitis compescit

Tabula Lepidium sativum

Vide EPROM (type, recognitio, serial numerus, connector locus JR/JS/JT)

Connectors ad VAMB

Duo 37‑pin D‑sub (JA1, JB1) - JB1 pro secundo TAMB

Customer Terminatio Clausus

48‑pin Euro obstructionum (TB1/TB2)

BNC Connectors

9 (unum per alveum)

Operating Temperature

0°C ad 50°C (32°F ad 122°F) - typicam pro Marco VI scrinium

Repono Temperature

-40°C ad +85°C (-40°F ad 185°F)

Umor

V% ad 95% non-condensing

Agency Approvals

Partis Marci VI systematis certificati UL, CSA, CE signa

Warranty

Sub GE vexillum productum warantia

Priora: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.