nyban1
Hic es: Home » Systems » Sensus Ratio » Additional Sensus cogitationes Nevada Bently » Benly Nevada 146054-12-05-02-05 Ceramic Probe Capped
Relinque nobis Nuntius

loading

Bently Nevada 146054-12-05-02-05 Ceramic Capped Probe

  • Bently Nevada

  • 146054-12-05-02-05

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

praecisio 146054-12-05-02-05 non-contactus propinquitatis est exploratio Benly Nevada 3300 a serie, specie machinata conditionis machinariae magnae in incrementis chemicis, altum pressuris, et extremae pH ambitus. Hoc exemplar est 3300 Ceramic Capped Probe featuring vexillum 3/8‑24 UNF filum ascendens instructum sine armis et cum 1.2‑inch altiore casu longitudinis conformatus , 5.0‑ metrorum totalis funis integralis , minima coaxialis ClickLoc iungo cum fune vexillum , ac multiplex approbationes internationales area ancipitia (ECSA, ATEX, I).

Definitiva notae explorationis huius familiae est alumina (Al₂O₃) pilei ceramici, quod extremum sensitivum tuetur. Haec ceramica materia eximiam duritiem, inertiam chemica et insulationem electricam praebet, eamque institutionibus optime aptam facit ubi specillum finis anterioris vaporibus exedentibus, liquoris ammoniaci, hydrogenii sulfidiae, aliisve instrumentis infestantibus obnoxius est. Specillus casus ex AISI 304 ferro immaculato fabricatur, validam mechanicam tutelam et resistentiam oxidationis et fovens in atmosphaerae humidae vel salinae praebens. Coniunguntur cum 3300 Proximitore sensore et funiculo extensionis, 146054-12-05-02-05 systema transducentem complet ad metiendi stipitem vibrationis, positionis axialis, et eccentricitatem in turbines, compressores, soleatus et fans.

Haec introductio praebet comprehensivam technicam descriptionem 146054-12-05-02-05 , suas mechanicas et electricas constructiones, operationes notas, limites environmentales, singula certificationes, optimas institutiones institutiones, ac interpretationem codicis ordinans. Omnes notitiae ex officiali Benly Nevada datasheet (J. 172932 Rev. J) derivata sunt et convalidantur pro casu specifico longitudinis et funis optionis selectae.

Design Philosophy and Construction

146054-12-05-02-05 . pertinet ad subsetlam 3300 ceramico-capped familiae evolutae pro applicationibus in quibus solum anterior pars speciosi casus conventus incidit humores aut vapores exesos Ante-finem ceramic‑to‑metalis interfacei rigorosum helium effluo experimentum subicitur officinas ut sigillum hermeticum praestet, ne quis ingressum agentium corrosivorum in sentiendi coil aut funem internam commissuram. Haec constructio rimis stricta aestimatur 34 Bar (500 psi) nitrogenium, cum modificationibus consuetudinum available pro altioribus pressuris requisitis.

Discrimen est ad intellegendum quod 146054-12-05-02-05 posteriorem non . congruentem vel immaculatam ferro Tubing comprehendere Quapropter extremum specillum extremum, ubi funis coaxialis causa exit -, non signatur . contra ambitum Hoc consilium electio geometriae specillum simpliciorem facit, sumptus minuit et faciliorem funem fugat, sed strictam limitationem operationalem imponit: postremum speciminis numquam patere debet ambitus perniciosos ut aqua, ammonia (NH₃), ammonium hydroxidum (NH₄OH), hydrogenium combustum, vel vaporem corrosivum cuiuslibet densantis. In praxi, hoc significat funem zonae exitus per mundum, siccum, non mordax areas fundi, typice intra pixidem seu instrumentum instrumenti tutelae coniunctionis. Pro applicationibus ad signationem plenam requirendam, 146056 variantes cum ferro incorrupto Tubingae et caerimoniae NPT loco seligi debent.

Casus 1.2 digiti longitudo in 146054-12-05-02-05 specificata codicem ordinans significat distantiam ab umero filo ascendente usque ad extremum specillum. Haec longitudo media praebet aequilibrium inter scopos reductos attingentes et rigiditatem mechanicam conservandam. Specillum inauguratum est utens 5/16-inch, clavis flatibus machinatis in casum, permittens applicationem torques moderari sine funem vel iungo efferens.

Applications animo

; 146054-12-05-02-05 aptissimum est ad missiones sequentes industriales

  • Anhydrous ammoniaci compressores in refrigeratione et productione stercorat

  • Chemical reactor seditiosos et mixers tractantem acidic vel causticas slurries

  • Princeps pressura centrifuga soleatus in petrochemical conflans

  • Turbomachinery sita est in suggestis remote contra ubi vapores salinorum et mordax vigent

  • Gas Turbine cibus skids et auxiliares expositae pellit gas uvae

  • Quodlibet instrumentum rotationis requirit certum stipitem vibrationis relativae vel positionis mensurationis in ambitibus pH‑extremis ubi vexillum 3300 XL rimatur immaturam corrosionem vel defectum.

Cap ceramicum galvanicum curas eliminat et praebet faciem chemicam inertem sentientem, quae per tempus non decedit, stabilitatem diuturnam mensurae praestans et intervalla sustentationem minuens.

Ordo Code Naufragii pro 146054-12-05-02-05

Numerus productus integer 146054-12-05-02-05 decoquitur ut sequitur:

Position

Segmentum

Code

Meaning

Base

146054

-

3300 Probe Ceramic Capped, 3/8‑24 UNF filo, sine armis

-AA

Causa Longitudo

12

1.2 pollices altiore causa longitudo (30,5 mm) - iussit in 0.1-inch incrementis

-BB

Totalis Cable Longitudo

05

5.0 metra (16.4 pedes) cable integralis

-CC

Connector et cable Type

02

Miniature coaxial ClickLoc iungo cum cable vexillum (non iungo protectorem)

-DD

Agency Approbatio

05

Approbationes multiplices: CSA (cNRTLus), ATEX et IECEx .

Cum ordinatio, necesse est ut chorda 11‑characteris 146054-12-05-02-05 plenam definias ut rectam casus longitudinem, funem longitudinis, stilum connectoris, et sarcina certificationis liberentur.

Installation and Gapping Guidelines

Propria institutio 146054-12-05-02-05 est critica ad mensuras accurate assequendas et ad vitae servitium protrahendum. Admonitiones practicas sequentia e data scheda et norma Bentleii Nevada ducuntur optimas exercitationes.

Specillum inauguratum est sequendo 3/8‑24 UNF filo escendendo in foramen apte percussum in machinae armamentis vel bracket ascendendo. In 5/16‑ inch clavis flatibus adstringendis moderandis permittit; torquis autem debet limitari ad vitandam stamina ponendo vel casu deformando. Expedit uti filo densis compositis vel ad libitum 04301007 nucis cincinnis cum nucleo securitatis foraminibus ad impediendam ob vibrationem resolutio.

Specillum hians requirit vigilantiam electricam quam tangentis mechanica gauges. Quia explorationes ceramic‑capped ostendunt variam linearem extensionem cum norma 3300 XL rimantis exhibere, consuetudo traditionalis hiatus mechanici secundum distantiam physicam fundandi non commendatur. Loco, specillum ad 3300 Proximitorem Sensorem et vim copiarum coniunge, deinde monitorem DC output voltage. Specillum pone, ut scopum (scapum) in linea intentionis lineae proxime -4 Vdc ad -16 Vdc jaceat. Medium intervallum (respondens ad circiter -10 Vdc) typice eligitur ut pari excursione in utramque partem permittat. Cavendum est, ne quis contactus corporalis inter summitatem ceramici et spiculum rotationis, sicut alumina materia dura sed fragilis est et sub ictu vel rimas asspirat. Tale damnum sub warantia non cadit.

Funis integralis 5.0‑ metre flexo radio saltem 25.4 mm fundi debet cum omnibus punctis (1.0 inch). Acutae kinks vel strictae flectiones coaxiales dielectricas perpetuo deformare possunt, immutantes proprietatem impedimenti et mensurae non lineari- tates causando vel detrimentum insigne. Ubi funem per ductum vel funem transit fercula, lenis adminiculis muniri debet, ne in coagmentationem vestigationis dimittatur.

Quia postrema 146054-12-05-02-05 non signatur, peculiaris attentio habenda est in area exitus fune. Si locus institutionis altam habet humiditatem, interdum condensationem, vel vapores chemicos, funem sursum fundi debet vel in cistam signatam coniunctam, ne liquores per funem persequantur et specillum intrantes agminis includant. Pro ambitus ubi hoc praestari non potest, 146056 variantes (cum posterioribus Tubing et NPT congruentibus) alternatio suadetur.

Calibration and System Interchangeability

3300 systema, incluso 146054-12-05-02-05 , officinas calibratas utens clypeo ferro AISI 4140 posito. Haec materia tamquam relatio eligitur quia congruenter torsit currente responsionem per frequentiam interest. Si scapus actualis machinae ex alio stannum construitur - exempli gratia, 304 chalybs immaculata, Inconel, titanium, vel superficies patella - scala factor et linearitas a valoribus officinarum deflectent. Bentley Nevada usum calibrationis offert pro talibus casibus; materia scopo definiri debet tempore ordinationis.

Mutabilitas error ±6,5% est clavis notae 3300 systematis. Substituit specillum substitutum, funem extensio, vel Sensorem Proximitorem institui posse sine plenam systematis recalibrationem, dummodo nova pars eiusdem generis ac longitudinis sit. Hoc simplificat sustentationem et tempus minuit. Attamen, pro applicationibus machinis criticis tutelae (exemplis vigilantiae vel intrusis), prudenter est utens verificationem in situ systematis adhibendo micrometer calibratus vel horologii coniecturam confirmet ad relationem gap‑to‑voltage sub condiciones operativas.

Periculosam Area Approvals and Conditions of Tutus Usus

146054-12-05-02-05 cum optione approbatione -05 multiplices certificationes internationales fert , idoneos faciens ad institutionem in atmosphaerae explosivae. Certificationes sequentes valent:

  • CSA (cNRTLus): Class I, Zona 0; AEx/Ex ia IIC T4/T5 Ga; etiam Classis I, Societates A, B, C, D; Classis II, Societates E, F, G; Classis III. Temperature classificationis T5 ambientium -55°C ad +40°C, et T4 pro -55°C ad +80°C. Pro Zona 2, nA/ec ratings similiter valent.

  • ATEX: II 1 G; Ex ia IIC T5…T1 Ga; et Ex ia IIIC T90°C ... T280°C Dc puluis ambitus.

  • IECEx: Ex ia IIC T5 ... T1 Ga; Ex nA/ec IIC T5…T1 Gc.

Ens parametri ad salutem intrinsecam (-ia) sunt;

Parameter

Precium

Ui (maximum input voltage)

-28 V

Ii (maximum input current)

140 mA

Pi (maximam input potestatem)

0.91 W

Ci.

1.5 nF

Li (inductio interna)

610 µH

Hi parametri validi sunt cum specillum per retinacula extensionis Benly Nevada connectitur ad Benly Nevada Proximitorem Sensorem qui cum entitate rating compatibilis communicat.

Conditiones usus tutos in certificatorio require:

  • Pro ia officinae Bentleii Nevada trahentem 141092.

  • Pro nA/ec (Zone 2) officinae trahere parere 140979. Proximitor constitui debet ita ut eius terminales saltem tutelam IP54 consequantur.

  • In schedula temperatura (vide tabulam infra) observari debet ut specillum temperaturae superficiei curet non auto‑ignitionem temperaturae atmosphaerae flammabilis aut pulveris pulveris ambientis.

Temperatus schedule pro Hazardous Areas (Probe tantum)

Temperature Classis

Licet Ambient Temperature Range

Applicationem (EPL)

T1

-55°C ad +232°C

Ga et Gc*

T2

-55°C ad + 177°C

Ga et Gc*

T3

-55°C ad + 120°C

Ga et Gc*

T4

-55°C ad +80°C

Ga et Gc*

T5

-55°C ad +40°C

Ga et Gc*

T280°C (Dc)

-55°C ad +232°C

Dc (pulvis)

T225°C (Dc)

-55°C ad + 177°C

Dc

T170°C (Dc)

-55°C ad + 120°C

Dc

T130°C (Dc)

-55°C ad +80°C

Dc

T105°C (Dc)

-55°C ad +100°C

Dc

T90°C (Dc)

-55°C ad +40°C

Dc

Ipsa 146054-12-05-02-05 caloris notabilis sub normalis operatione non generat; temperatura classificatio principaliter dependet ex maxima temperatura ambientium institutionis situs. Specillum in omnibus recensitis T‑ratings occurrit, cum intra limites definitos ambientium operata est.

Limitations and Critical Admonitiones

Users 146054-12-05-02-05 stricte adhaerere debent his limitibus ut operationem tutam et certam obtineant.

Specillum postremum non hermetically signatum est . Patefacio funis exitus et casus posterioris ad aquam, ammoniam, ammonium hydroxidum, hydrogenium misy, vel quodlibet chemicum corrosivum deducet ad degradationem celeris insulationis FEP, corrosionis centri conductoris, et breves circumitus vel apertae defectionis eventualis. Hoc unum est maximi momenti operationis ad hoc exemplar.

Apicem ceramicum mechanice contra impetum chemicarum robustum est sed susceptibilis est ad damnum ictum. Quilibet directus contactus cum hastili rotationis, sive in institutione, sustentatione, sive in condicionibus machinae caducis, potest facere detractionem, rimas, vel integram fracturam aluminae cap. Hoc damnum statim calamitosum est ad integritatem mensurae et ad warantia producto non cadit. Mechanica terminationum vel intervalli instrumentorum occasum summa diligentia utendum est.

Pressio rating 34 Bar (500 psi) proprie ad sigillum ceramic‑to‑metalis applicatur. Non implicat totum corpus specillum differentialem pressioni per fila ascendentem sustinere posse. Si processus pressionis hunc valorem excedit, consuetudo machinalis modificationes requiruntur - placet consule Bentley Nevada.

Post proelium ultra 0,563 digiti (14.3 mm) vetitum est. Stamina interna perforati adscendentis conformare debent ad industriam vexillum apta classes filo externo adaptans. Si foramen altius commendatur quam pugna, filo vel cincinno nuce utendum est ad profunditatem inserendam.

Cable inflexionem radii servari oportet vel supra 25.4 mm (1.0 pollicis). Radii minores deformationem faciunt de coaxial dielectric et capacitatem per unitatem longitudinis mutant, errores mensuras introducendi et potentia causandi signum stillicidium intermittentes.

Accessories pro 146054-12-05-02-05

Quamvis 146054-12-05-02-05 sine iungente protectore vel armis praebeatur, plura accessoria praesto sunt ad robur institutionis et tutelae environmental augendae. Tabulam sequentem recenset vulgatis comitibus ordinatis.

Pars accessoria Number

Descriptio

40113‑02

Connector Protector Ornamentum speculatoriae et funes extensionis; institutionem includit instrumenta. Nota: protector femina (03800001) separatim ordinari debet.

136536‑01

Connector Protector Adaptor – permittit usum instrumentorum institutionis pre‑1998 cum modernis 75 Ω ClickLoc connexionibus.

03839410

75 Ω Triaxial Male Connector Protector — inauguravit funem extensionem et socios cum protectore foemineo in specillo.

03800001

75 Ω Coaxial Female Connector Protector - in specillum plumbi installed; usus est etiam in funibus extensionis ad custodiam nexum cum sensore Proximitori.

04301007

3/8‑24 Probe Lok Nut cum fili foraminibus tutus – specillum in positione munit et ob vibrationem solvens impedit.

Bently_Manuals

Customer DVD continens omnes manuales Benly Nevada, notas applicationis, firmware (FWD), et duces institutionem in omnibus linguis sustentatis.

Ad institutiones armorum funes requirentes (praesidium mechanicum contra abrasionem vel contritionem), exemplum basis 146054 cum modificatione 164523 ordinari potest, sed haec pars non est configurationis 146054-12-05-02-05 . Si armatura essentialis est, alia ordinatio Codicis specificari debet.

Comparatio cum aliis variantibus

a 146054-12-05-02-05 siblings maxime differt in casu longitudinis et optionum approbationum. Casus longitudo -12 1.2 digitorum est electio medialis, brevior quam maximo 4.0 digitorum, sed longior quam minimae 0,8 dig. Haec longitudo saepe eligitur ut specillum extremum ponatur ad distantiam specificam ab superficie scapo reducto vel ad obstructiones structurarum manifestandas. Tota -05 longitudo (5.0 metrorum) est norma oblationis pro officinarum officinarum maxime; longiores 9.0‑ funes metreti praesto sunt sed onus capacitatis altiorem imponunt.

Comparatus cum 146056 variantibus, 146054-12-05-02-05 cum sigillo caret tergo et ferro incorrupta Tubing. Ergo minus sumptuosus et facilius est instituere sed postulat mundum, aridam tergo environment. E contra, 146056 ad utrumque finem plene obsignatum est et NPT exitu caerimonias pro nexus aquaeductuum includit, idoneos ad condiciones humidas vel mordax postremas faciens.

Ad sequelam metricam requisita (M10 x 1), exemplar 164517 specificandum loco 146054 debet. Praesens exemplar adhibet filum imperialium 3/8‑24, quod manet vexillum communissimum in American Septentrionali et multis applicationibus turbomachinarum internationalium.

Tabulae sequentes omnes essentiales electricas, mechanicas, environmentales, perficiendas et certificationes parametri pro 146054-12-05-02-05 exhibent . Nisi aliter indicatur, valores applicabiles ad systema complendum 3300 5 mm comprehendentem specillum, extensionem cable adaptans, et Sensorem Proximitorem, operantem ad temperaturam ambientem inter +18°C et +27°C cum copia potentiae -24 Vdc, onere 10 kΩ, et scopum ferro AISI 4140. Characteres euismod tantum valent, cum genuina Bently Nevada 3300 XL systematis componentibus utens.

Systema euismod Characteres

Parameter

Specification

Ratio Type

3300 5 mm

Standard Target Material

AISI (IV)CXL Steel (calibration officinam)

Nominal Supple Voltage

-24 Vdc

Impedimentum minimum Lond

10 kΩ

Linearibus mensurae dolor

1.52 mm (60 mils), incipiendo fere 0,25 mm (10 mils) ab scopo et usque ad 1,78 mm (70 mils)

Output intentione super lineari dolor

Proxime -4 Vdc ad -16 Vdc (negative, eundo)

Incremental Scale Factor (ISF)

7.87 V/mm (200 mV/mil) ±6,5 % inter mutabilitatem errorum, in 0,25 mm mensurata (10 mil) gradibus super plenam 60 mil, ab 0°C ad +45°C

Commendatur Installation Gap

Hipant specillum electrically vigilantia output voltage; vitare contactus corporis inter ceramic tip et spiculum revolventis

Error permutabilitas

±6.5% maximum, cum reponatur aliqua ratio componentis (proba, extensio, seu Proximitor) in eadem familia producti.

Ratio Accuracy

AISI 4140 solum certum scopum; consuetudo calibratiis praesto ad alias materias scopo petentibus

Characteres electrica (Probe‑tantum)

Parameter

Specification

Nominal DC Resistentia (Centre ad Conductor exterioris)

Ad 5.0‑ metrerum funem integrum, resistentia squamarum per schedae datae; valor typicus est circiter 8.73 Ω± 0.90 Ω (referenced to 5.0 m length)

Cable Impedimentum

75 Ω coaxialis ethylene fluorinata propylene (FEP) insulation

Connector Type

Minima coaxial ClickLoc, inaurata

Connector Base Material

Aes inauratum, vel auri patella beryllium

Maximum Connector Torque

0.565 N·m (5 in·lbf) — cominus digitus strictus satis est; iungo sonore 'clicks' cum recte iunguntur

Cable Minimum Subjicite Radius

25.4 mm (1.0 inch) - radius ille excedens conductor interior laedat et impedimentum minuat

Facultatem (Ci) ad Periculosam Area

1.5 nF (ens parametri)

Inductione (Li) ad Periculosam Area

610 µH.

Mechanica Specificationes

Parameter

Specification

Probabile consilium Material

Alumina ceramic (Al₂O₃) - summus puritas, chemica inertia, alta fortitudo dielectrica

Probe Casus Material

AISI 304 Steel - austenitic, non magneticus, corrosion‑resistens

Adscendens Thread

3/8‑24 UNF 2A (per ANSI/ASME B1.1)

Longitudo altiore Causa (Bene -12)

1.2 pollices (30,5 mm) - metiri ab ascendente filo umero usque ad summitatem faciei

Maxime permissible Case Longitudo (pro hac familia)

4.0 pollices (101.6 mm)

Minimum casu licet Longitudo (pro hac familia)

0,8 pollices (20,3 mm) - 1.2‑inch optio jacet commode intra licita range

Totalis Cable Longitudo (Option -05)

5.0 metra (16.4 pedes) - integralis, non amovibilia

Cable Type

75 Ω coaxialis, conductor singularis, velit FEP, ad continuum expositionem aptam usque ad +177°C

Connector and Cable Option (-02)

Miniature coaxial ClickLoc iungo cum cable vexillum; iungo protector non includitur

Armor

Non aptavit (productum variant sine armis)

clavis blandit

5/16‑inch (7.94 mm) per blandit in specillo casu ad institutionem

Probe consilium Diameter

7.0 mm (0.273 inches) nominalis

Threaded Section Diameter

7.2 mm (0.285 digiti) nominalis

Maxime commendatur Thread sponsio

0.563 inch (14.3 mm) - Commissio ultra hunc modum ligare potest et non cadit sub warantia

Environmental et Impetus limites

Parameter

Specification

Temperature dolor operating (Probe tantum)

-51°C ad 177°C (-60°F ad +351°F)

Repono Temperature Range

-51 ° C ad CLXXVII ° C (sicut operating)

Maximum Front‑End Sigillum Pressure

34 Bar (500 psi) NITROGENIUM - belium rimosum apud officinas probatum; modifications available for altioribus pressuris

Tergo finem Sigillum

non signatus custodiendus est ab vaporibus corrosis, humoribus, et humore densante Funis posterioris exitus

Relativum Umor

0 ad 100% condensatione (cum opportunitate iungo praesidio et sicco tergo environment)

Ingressus Praesidium (cum connexiones iuncta)

Minimum IP54 cum iungo protectores sunt idoneus et rite installatus

Post sponsio limites

Post Location

Maximum commendatur proelio Longitudo

3/8‑24 UNF

0.563 inch (14.3 mm)

M10 x 1 (metric variant)

5 mm (nam tantum referat)

In 146054-12-05-02-05 stamina 3/8–24 utitur; Itaque maximum proelium tutum est 0,563 inch. Hic modus industriae modum sequitur 1.5 temporibus stamina nominalia diametri. Hoc valore excedens, potest specillum ligare intra foveam adscendentem, ducens ad stamina pungentia vel fractura specilli. Bentley Nevada propinquitatem nevada substituit sub warantia explorat damnum quod ex nimio sequelae proelio provenit.

Cable and Connector Details

Parameter

Specification

Cable Type

75 Ω coaxialis, conductor unius centri cum FEP dielectric et jacket

Cable exterioris diametri

Proxime 2.5 mm (0.1 inch)

Totalis Longitudo Tolerantia

+20% / -0% ad 5.0‑ metretarum longitudinis (id est, funis leviter longior, sed numquam brevior)

Pars Connector Number (Reference)

ClickLoc exiguum coaxial (aureum patella)

Connector adstringens Methodo

Digitus strictus solum - densis mechanismus efficit tangentes et audibiles click; nulla instrumenta requiratur

Connector Protector

Not supplied with optio —02; available ut separatum accessorium (03800001 femina protector)

Removable Nux configurationis

Non convenit - hoc exemplar utitur ad fixum-nut ClickLoc iungo

Previous: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.