216NG63 est Auxiliaris DC Potestatis Unitis in ABB RE. 216 series systematis generantis ac tutelae. Pertinet ad 216NG6. series DC/DC convertentium. Haec unitas specialiter destinatur ad ambitus industriales sicut potentia systematis substations et potentiae plantarum. Praecipuum eius munus est in intentione stationis altilium stabilis 24 V DC copiae potestatis convertendi, firmam potestatem operandi omnibus modulis electronicis et input/output unitates in REG 216 / REC 216 convertendi.


216NG63 aptum est 220 V / 250 V DC systemata altilium statio, lato initus intentione 165 V ad 312.5 V DC. Tolerantiam intentionis offert ±25%, ut eam aptare possit ad communes voltages ambigua potentiarum systematum.

2. Key functiones

1. intentione Conversio & Electrical Isolatio

Core munus 216NG63 est summus intentionis DC initus (exempli gratia 220/250 V DC) in 24 V DC potentiam visam ab instrumento electronic systematis requisitam. Internum consilium summus frequentia mutandi vim technologiam adhibet, dum electricam solitudo inter input et output. Hoc efficaciter impedit detrimentum armorum tutelae ex causis potentialibus differentiis et impedimentis.

2. Superuacua Power Support

Systema configurari potest ad copiam unius vel dualis redundantis virtutis. In modum redundanti, duae unitates 216NG63 ad systematis potentiae parallelae agunt. Si una unitas deficit, altera ratio normalem conservare potest, signanter fidem augendae tutelae.

3. Power Status Cras & Alarm

216NG63 lineamenta propriae vigilantiae facultates comprehensivae sunt;

  • Front Panel Indicatores:

    • 'U IN' Green DUXERIT: praesens indicat input intentione.

    • 'U EX' Green DUXERIT: indicat output intentionis praesens est.

    • Utraque LEDs simul accensa significat operationem normalem machinam.

  • Remota signum output:

    • '24 V Insufficientia' signum per nullam internam K100.

    • Systema status informationes per CK (Stand-by) et SML (System Defectus) bus linearum signo datos misit.

4. Flexibile configurationis

Potentia copia output modus mollius per obturaculum-in jumpers A et B in tergo unitatis collocari potest:

  • Utriusque Jumpers Insertus est: Unitas potestatem tribuit utrique USA et USB bus lineis.

  • Unius Supple Modus: Unitas potestatem uni tantum bus lineis tribuit, apta systematibus non redundantibus vel configurationibus specialibus.

5. Grand Praesidium

216NG63 in onere et brevi circuitu tutelae circuitus aedificavit. Si deprauatio output (eg, brevis-circuitu vel supercurrente) deprehenditur, statim abscindit output ne fabrica damni fiat, et personas sustentationes summis per tabulas anteriores LEDs vel remotis significationibus.


3. Opus Principium

1. DC/DC Conversio Principii

In 216NG63 summus frequentia mutandi copia technicae potentiae utitur. Vi utitur machinis mutandi (ut MOSFETs vel IGBTs) ut initus DC intentione in signum praecipuum frequentiam AC convertat. Haec igitur per altum frequentiae commutator descendens ac demum in stabulo 24 V DC output per rectificationem et circuitus percolando conversus est. Haec methodus praebet altitudinem efficientiam, magnitudinem compactam, et dispositionem intentionis optimam.

2. Redundant Supple Mechanismum

In systemate redundante, duae 216NG63 unitates potestatem independentem USA et USB 24 V bus lineae independentiae supplent. Omnes moduli electronici et I/O unitates potestatem trahunt ab utroque bus lineis. Si una potentia copia deficiat, altera adhuc ratio operationis conservare potest per reliquas lineas, quae supplere vim 'continuum' obtinent.

3. Status videre & Ratio Integration

216NG63 non solum potentiam praebet, sed etiam cum aliis modulis in systematis parallelis per B448C communicat;

  • CK Line: Status signum consuevit mittere 'Sta-by'.

  • SML Linea: Ratio Defectus terroris signum solebat mittere.

  • K100 Nullam: dat potentiale liberum contactus output qui adhiberi potest ad vigilantia remota vel cum aliis machinis interlocking.


4. Structure & Hardware Design

Mechanica 1. Structure

  • Ascendens: Designatur vexillum 19″ eculei, cum latitudine 3T (singulis T= 17 mm) et altitudine 6U.

  • Plug-in Design: subsidia calida plugging (facienda est cum potentia auxilia auxiliaria), sustentationem et reponendam expediat.

  • Front Panel: Instructus indicibus DUXERIT et praecipua potentia switch (I/O).

  • Postrema Panel: Features input/output terminales et bases ob plug-in jumpers A et B.

2. Electrical Interfaces

  • Input Terminales: Pertinent ad terminos positivos et negativos stationis pugnae (UB+ / UB-).

  • Output Terminals: Provide 24 V DC output in USA/USB buses et I/O modulos.

  • Communicatio interface: Communicate cum aliis unitatibus electronicis systematis per bus B448C.

3. Caloris Dissipatio & Praesidium

216NG63 naturalis convection refrigerationem utilitas est. Habitatio ordinatur ad dissipationem caloris efficax, apta ad condiciones operandi summus temperatus in ambitibus industrialibus. Cogitatus in IP30 classi tutelae obsecutus est, ne ingressus magnarum rerum externarum solidorum.


5. configurationis & Occasus

1. DESULTOR Optiones

Users statum jumpers A et B exponere possunt num ratio vim redundantem requirit;

  • Modus redundans: Jumpers A et B inseruntur ambae unitates 216NG63.

  • Unius Supple Modus: Una unitas jumpers insertas habet (exempli gratia bus praebens), altera autem eas subtrahit (exempli gratia modulorum tantum I/O modulorum), secundum figuram.

2. Ratio Integration

216NG63 opera coniuncta cum hisce modulis clavibus in systemate RE.216:

  • 216VC62a Processing Unit: Systema logicae et tutelae functiones praebet.

  • 216EA61 Analogus Input Unit: Acquirit signa currenti/voltage.

  • I/O Unitas sicut 216AB61/216DB61: Signum fac output et iter imperium.


6. Salutis & Sustentacionem

1. Safety Operating Ordinationibus

  • Stricte Prohibitum Live Plugging/Unplugging: Omnes moduli electronici tantum inseri vel removeri possunt postquam copia potentiae auxiliaris abscissa est.

  • Dual Power Shutdown: Si ratio cum copiarum copiarum redundante configuratur, utraque 216NG63 unitates ante opus in eculeo mutandae sunt.

  • Personae secundum quid: Omnes setup, wiring et committendo opus exerceri debent ab institutis et idoneis curatoribus.

2. Culpa Diagnosis

  • Si 'U EX' DUCTUS est off, inputationem intentionis, thoracem laneum reprime, et onus output.

  • Si culpa interna suspecta est (exempli gratia, sine output, terror), contactus ABB pro reparatione.

  • Si terror longinquus utitur, statum K100 Nullam et bus significationibus reprehendo.

3. Repair Policy

Users non debent discurrere vel mutare ambitum internum seu programmatum 216NG63. In casu defectus, tota unitas ABB restitui debet vel ministerium authenticum pro reparatione centri. Alienigena sollicitare warantum nullatenus irritabit.


7. Application missiones

216NG63 late adhibetur in sequentibus instrumentorum armorum tutela et potestate systemata;

  • Generator Protectionis Systems (REG 216)

  • Unitas Imperium Numericum (REC 216)

  • Medium- and High-Voltage Substation Automation Systems

  • Praesidia Systemata pro magnis Motoribus, Potestate Transformers, et Foederatis



Specification Categoria Parameter Nomen Technical Specification & Description
Basic Electrical Parameters Product Model 216NG63

Device Type DC / DC Converter (Auxiliare Power Unit)

Rated Input Voltage (U B ) 220 / 250 V DC

Input intentione dolor 165 V ad 312.5 V DC (± 25%)

Rated Output intentione 24 V DC

Output Power Refer ad ABB Datasheet (1MRB520004-Ben) pro specifica potentia rating

Electrical solitudo Provisum inter initus et output
Characteres functiones Dundantia Support Etiam ratio redundans formare potest cum alio 216NG6. series unitas

Status Indicis Fronte panel cum 'U IN' (input intentione) et 'U EX' (Output intentione) viridi LEDs

Remota significantes '24V Insufficientia' potentiale liberum contactus per nullam internam K100; status communicationis per CK et SML bus lineae

Configurationis Set modus copia virtutis (uno / redundans) per obturaculum-in tergo jumpers A et B

Praesidium functiones Includes onus and brevis-circuitu tutela; output est statim peribit in culpa
Mechanica & Connection Adscendens Specification Ad vexillum 19-inch tormenta (216MB66 / 216MB68)

Unit Latitudo 3T (singulis T=17 mm, latitudo totalis approx. 51 mm).

Connection Type Front: Plug-in modulus. Tergo: Terminatio cuneos ac thoracem laneum totidem.

Initus / output Interfaces Input: Stationis altilium (UB+ / UB-) terminales.
Output: 24V ad USA/USB buses et I/O modulorum.
Environment & Safety Praesidium Classis IP30 (Praesidium contra solida res externas > 2.5mm)

Refrigerationem Methodo Naturalis Convection

Safety operational Vivere linamentis / unplugging prohibitus; sustentationem per personas tantum, quid

Reparare Policy Usor reparare non permittitur; unitas rediit ABB vel auctoritate muneris centrum
Application & Compatibility Lorem Systems ABB RE.216 series (REG 216 Protection Generator, REC 216 Unitas Imperium)

Compatible Unitates Opera cum 216VC62a Processing Unit, 216EA61 Analogue Input Unit, 216AB61/DB61 I/O unitates, etc.

Typical Applications Potentia plantarum, MV/HV substationes, systemata tutela in magnis motoribus et transformatoribus




Previous: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
Email  :  sales2@exstar-automation.com / lily@htechplc.com
 Oratio: Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.