IQS900 204-900-000-011 A5-B21-C1-H05-I1 Signal Conditioner

  • VM

  • IQS900 204-900-000-011 A5-B21-C1-H05-I1

  • $2000

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The IQS900 Signal Conditioner is a high-performance, modular core component of the non-contact eddy current displacement measurement system from Parker Meggitt (formerly the vibro-meter product line). It works in conjunction with the TQ402/TQ412 series eddy current sensors and the EA402 extension cable to form a complete displacement/vibration measurement chain, enabling real-time, precise measurement of critical parameters such as relative shaft vibration, axial displacement, eccentricity, and rotational speed in rotating machinery.


The specific model IQS900 204-900-000-011 A5-B21-C1-H05-I1 is a high-precision signal conditioner with international explosion-proof certification, specially designed for Zone 2 gas hazardous areas and Zone 22 dust hazardous areas. It features a 2 mm small measurement range design with a high sensitivity of 8 mV/μm, making it suitable for small gap measurement scenarios requiring extremely high accuracy. The product complies with API 670 standard recommendations and is compatible with mainstream monitoring systems such as VM600 and VibroSmart, making it an ideal choice for rotating machinery monitoring in explosion-proof applications such as petrochemical, natural gas, and offshore platforms.



Key Features

  • Non-contact eddy current measurement principle: Based on high-frequency electromagnetic field induction, unaffected by media such as oil and water vapor, suitable for dynamic and static measurements of high-speed rotating machinery.

  • High sensitivity: 2 mm linear measurement range, sensitivity 8 mV/μm (200 mV/mil), output voltage -1.6 V ~ -17.6 V.

  • Wide frequency response: DC ~ 20 kHz (-3 dB), supports both static displacement and dynamic vibration measurement simultaneously.

  • Low output impedance: < 100 Ω (DC), < 300 Ω (20 kHz), supports long-distance signal transmission.

  • Functional safety: Hardware design meets SIL 2 (IEC 61508) capability requirements.

  • Explosion-proof certifications: ATEX, IECEx, CCSAus, UKEX, KGS, EAC and other international explosion-proof certifications, suitable for Zone 2 gas and Zone 22 dust hazardous areas.

  • Temperature compensation: Maintains measurement stability across the full temperature range of -40°C ~ +85°C.

  • Modular design: Plug-in screw terminals simplify on-site wiring and maintenance.

  • Flexible mounting: Supports DIN rail (TH 35) mounting or direct fixing with M4 screws.

  • Interference immunity: Complies with EN 61000-6-2/4 industrial environment electromagnetic compatibility standards.

  • Protection functions: Outputs feature overvoltage (-33 VDC typical) and short-circuit protection (35 mA current limiting).

  • System interchangeability: Sensors, cables, and conditioners are all interchangeable without requiring recalibration.



Model Code Breakdown

Code SegmentDescriptionDetailed Explanation
IQS900Base modelvibro-meter® product line signal conditioner
204-900-000-011Internal version/configurationSpecific hardware version and firmware configuration identifier
A5Explosion-proof optionExplosion-proof version, suitable for hazardous areas (Ex ec IIC T6/T5 Gc)
B21Measurement range/output2 mm measurement range, voltage output, sensitivity 8 mV/μm
C1Diagnostic functionNo diagnostic function (C2 is version with diagnostics)
H05Housing/connectorStandard metal housing with plug-in screw terminals
I1Interface optionSpecific connector/cable interface configuration (may correspond to explosion-proof interface requirements)

Note: The exact meaning of model codes may change with product revisions. It is recommended to confirm with the latest data sheet or official information from Parker Meggitt.



System Composition and Operating Principle

System Composition

The complete IQS900 measurement system consists of the following three components:

ComponentModel (Explosion-proof Version)Functional Description
SensorTQ402-A2 or TQ412-A2Non-contact eddy current probe, detects gap to metallic target. TQ402 is standard mount type, TQ412 is reverse mount type (for space-constrained applications).
Extension CableEA402-A2Connects sensor to signal conditioner, extends installation distance, available in various lengths.
Signal ConditionerIQS900 A5Provides excitation signal to sensor, processes sensor impedance change, outputs voltage signal proportional to gap.

Operating Principle

  1. Excitation: The internal high-frequency oscillator in the IQS900 generates an excitation signal, driving the sensor coil via the cable, creating a high-frequency electromagnetic field around the coil.

  2. Induction: When a metallic target (e.g., a rotating shaft) approaches the sensor tip, eddy currents are induced on the target surface. These currents react back on the sensor coil, altering its equivalent impedance.

  3. Demodulation: The modulation/demodulation circuit inside the IQS900 detects the impedance change and converts it into a linear voltage signal proportional to the target gap.

  4. Output: The output voltage signal (-1.6 V ~ -17.6 V) is transmitted via screw terminals to the monitoring system for display, alarm, or protection actions.



Performance Curves and Measurement Data

Output Characteristics

Under standard test conditions (target material: VCL 140 steel, temperature: 23°C ± 5°C), the typical output characteristics of IQS900 with TQ402 are as follows:

Gap (mm)Output Voltage (V)
0.15-1.6
0.50-4.4
1.00-8.8
1.50-13.2
2.15-17.6

The output voltage has a highly linear relationship with the gap, with a slope of 8 mV/μm.

Linearity Error

Over the entire measurement range (0.15 ~ 2.15 mm), the typical linearity error is < ±50 μm (relative to the ideal straight line), with maximum error < ±100 μm.

Temperature Drift

Temperature RangeMaximum Drift
-40°C ~ +180°C< 5% of full scale
+180°C ~ +220°C> 5% (short-term survival)

Frequency Response

The frequency response is flat up to 20 kHz (-3 dB), meeting the vibration measurement requirements of most rotating machinery.



Installation and Connections

Mounting Methods

  • Direct Screw Mounting: Via two M4 threaded holes on the bottom (85 mm spacing) onto a mounting plate or inside a cabinet.

  • DIN Rail Mounting: Using the MA130 rail adapter for quick installation on TH 35 standard rails (according to EN 50022 / IEC 60715).

Connector Definitions

Interface LabelTypeFunction
SENSORMiniature coaxial socketConnects to sensor or extension cable
RAW/COM2-pin terminalRaw output signal (-0.8 V ~ -8.8 V)
TEST/COM2-pin terminalTest input signal (for external signal injection)
O/P/COM2-pin terminalMeasurement output signal (-1.6 V ~ -17.6 V)
-24V/COM2-pin terminalPower input (-19 V ~ -30 VDC)

Explosion-proof Installation Notes

  • The IQS900 must be installed in an enclosure with at least IP54 protection rating.

  • The enclosure should be suitable for hazardous areas with appropriate markings.

  • All cable entries must use explosion-proof cable glands to ensure sealing.

  • Coaxial connectors should be hand-tightened until locked; do not use tools to overtighten.

  • Terminal blocks are pluggable for pre-wiring convenience, but must be operated with power disconnected.



Accessories and Options


Accessory NameModelDescriptionExplosion-proof Suitability
DIN Rail Mounting AdapterMA130For mounting IQS900 on TH 35 railsGeneral
Industrial Protection EnclosureABA17xProvides IP54+ protection, suitable for field installationCan be used in Ex areas
Interconnection ProtectorIP172Protects sensor-to-cable connection point, oil and water resistantGeneral
Junction BoxJB118For centralized wiring of multi-channel signal conditionersEx version optional
Flexible ConduitKS107Provides mechanical protection for sensor cablesGeneral
Cable FeedthroughSG1xxFor sealing and fixing cables entering cabinetsEx version optional
Probe Mounting AdapterPA15xFor mechanical positioning of TQ402/TQ412 sensorsGeneral
Extension Cable (Ex Version)EA402-xxx-A2Available lengths: 0.5 m ~ 10.0 m, with A2 intrinsic safety ExEx ia
Sensor (Ex Version)TQ402-xxx-A2 / TQ412-xxx-A22 mm range, with A2 intrinsic safety ExEx ia




Total System Length and Cable Combinations

When the IQS900 is used with TQ402/TQ412 and EA402, the supported Total System Lengths (TSL) are 1 m, 5 m, and 10 m. The following table lists recommended cable combinations:

Total System LengthSensor Cable LengthExtension Cable LengthRemarks
1 m1.0 mNoneNo connector, highest reliability
5 m0.5 m4.5 m
5 m1.0 m4.0 m
5 m1.5 m3.5 m
5 m2.0 m3.0 m
5 m5.0 mNoneNo connector
10 m0.5 m9.5 m
10 m1.0 m9.0 m
10 m1.5 m8.5 m
10 m2.0 m8.0 m
10 m5.0 m5.0 m
10 m10.0 mNoneNo connector

Cable Length Trimming

Due to the electrical characteristics of the coaxial cable, the actual cable length requires electrical trimming to ensure system performance and interchangeability:

Nominal Total System LengthMinimum Actual Length
1 m0.9 m
5 m4.4 m
10 m8.8 m

When ordering, specify the required nominal length; Meggitt will perform internal electrical trimming.



Compatible Monitoring Systems

The output signal from the IQS900 can be directly connected to the following monitoring systems (in Ex applications, must be connected via safety barriers or isolation units):


System SeriesCompatible Modules/DevicesRemarks
VM600 / VM600 Mk2IOC4T, IOC16T, IMC4T, etc.Requires appropriate input modules
VibroSmart®VSM100, VSM101, etc.Distributed monitoring system
GS1127Galvanic Isolation UnitFor safety area isolation
Third-party PLC/DCSAnalog input modulesMust meet input impedance requirements: voltage input ≥ 50 kΩ, current input ≤ 350 Ω, and comply with Ex area requirements




Ordering Information

ComponentModelDescription
Signal ConditionerIQS900 204-900-000-011 A5-B21-C1-H05-I12 mm range, voltage output, no diagnostics, Ex version, H05 housing, I1 interface
Sensor (Ex Version)TQ402-xxx-A2 or TQ412-xxx-A2Select integral cable length (e.g., 1.0 m, 5.0 m, 10.0 m), select mounting type
Extension Cable (Ex Version)EA402-xxx-A2Select length (e.g., 4.5 m, 5.0 m, 9.0 m, etc.)
Mounting AdapterMA130Optional DIN rail mounting

Note: "xxx" in the specific ordering numbers represents cable length. Please consult Parker Meggitt or an authorized distributor for complete ordering codes.



Typical Application Examples

Example 1: Compressor Vibration Monitoring in Oil Refinery

  • Scenario: Critical gas compressors in an oil refinery are located in Zone 2 hazardous areas, requiring real-time monitoring of shaft vibration and axial displacement.

  • Solution: Each compressor is equipped with 4 TQ402-A2 sensors (radial vibration) and 2 TQ412-A2 sensors (axial displacement), connected via EA402-A2 extension cables to IQS900-A5 signal conditioners installed in an explosion-proof cabinet, with output signals connected to the VM600 monitoring system.

  • Result: The system operates stably, successfully providing early warnings for multiple potential failures, avoiding unplanned shutdowns.

Example 2: Gap Monitoring of Offshore Platform Turboexpander

  • Scenario: The rotor-to-casing gap of a turboexpander on an offshore natural gas platform is extremely small, requiring high-precision monitoring, and the platform is classified as a hazardous area.

  • Solution: TQ402-A2 sensors combined with IQS900-A5 (B21 configuration) are used, with the 2 mm range providing 8 mV/μm high sensitivity for precise gap monitoring.

  • Result: Achieved gap measurement at 0.01 mm resolution, ensuring equipment safety.



Safety and Maintenance Recommendations

  1. Before Installation:

    • Verify that the product model and explosion-proof markings meet the site area classification requirements.

    • Inspect the product for external damage and ensure connectors are clean.

  2. During Installation:

    • Strictly follow explosion-proof installation codes, ensuring correct enclosure protection rating and cable entry methods.

    • Hand-tighten coaxial connectors to lock; do not use tools.

    • Terminal block insertion/removal should only be performed with power disconnected.

  3. During Operation:

    • Regularly check enclosure seals and cable glands for tightness.

    • The monitoring system should record IQS900 output signals; if anomalies are detected (e.g., output outside normal range), immediately inspect the measurement chain.

  4. Maintenance:

    • Before maintenance in hazardous areas, obtain work permits and disconnect power.

    • Clean with a dry soft cloth; do not use organic solvents.

    • When replacing components, use identical models and explosion-proof等级 spares.

  5. Disposal:

    • Dispose of products as electronic waste in an environmentally friendly manner; do not discard randomly.


Technical Specifications Overview

General Specifications

ParameterSpecification
Product NameIQS900 Eddy Current Displacement Measurement System Signal Conditioner (Ex Version)
Compatible SensorsTQ402 / TQ412 Series (2 mm range, must use explosion-proof version A2)
Compatible Extension CableEA402 Series (must use explosion-proof version A2)
Measurement PrincipleHigh-frequency Eddy Current
Measurement Range2 mm (Linear range: 0.15 ~ 2.15 mm)
Output TypeVoltage output (3-wire)
Sensitivity8 mV/μm (200 mV/mil)
Output Signal Range-1.6 V ~ -17.6 V (corresponding to min. to max. gap)
Frequency ResponseDC ~ 20 kHz (-3 dB)
LinearityTypical error < ±1% (refer to performance curves)
InterchangeabilityAll system components interchangeable without recalibration

Electrical Specifications

ParameterSpecification
Output Impedance< 100 Ω (DC), < 300 Ω (20 kHz)
Load RequirementMonitoring system input impedance ≥ 50 kΩ (recommended)
Raw Output (RAW)-0.8 V ~ -8.8 V (nominal), output impedance < 15 kΩ (DC)
Test Input (TEST)Input voltage range ±0.1 ~ 4.0 Vp-p, input impedance 500 kΩ
Power Supply Voltage-19 V ~ -30 VDC (voltage output mode)
Power Consumption< 25 mA @ -24 VDC
Overvoltage Protection-33 VDC (typical)
Short-circuit ProtectionOutput short-circuit protection (35 mA current limiting)

Environmental Specifications

ParameterSpecification
Operating Temperature-40°C ~ +85°C (T6 rating: -40°C ~ +70°C; T5 rating: -40°C ~ +85°C)
Storage Temperature-40°C ~ +85°C
Humidity Range0 ~ 95% RH (non-condensing)
Ingress Protection RatingIP20 (Requires installation in enclosure with at least IP54 rating to meet explosion-proof requirements)
Flammability RatingUL94 V-0
Vibration Resistance5 g (10 ~ 500 Hz) according to IEC 60068-2-6
Shock Resistance15 g (11 ms half-sine wave) according to IEC 60068-2-27

Mechanical Specifications

ParameterSpecification
Housing MaterialPainted aluminum alloy
Electrical ConnectionsSensor side: Self-locking miniature coaxial connector; Power/Output side: Plug-in screw terminals (supports 0.2 ~ 1.5 mm² wire)
Mounting MethodTwo M4 screws, or via MA130 adapter for TH 35 rail (according to EN 50022 / IEC 60715)
WeightApprox. 200 g (without adapter)
Dimensions (W × H × D)Approx. 100 mm × 80 mm × 30 mm (excluding connectors)

Compliance Standards


Standard TypeSpecific Standards
Electromagnetic CompatibilityEN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions), EN 61326-1, EN 61326-3-2
Electrical SafetyEN 61010-1
EnvironmentalRoHS 2011/65/EU
Functional SafetyIEC 61508 (SIL 2 capability)
Explosion ProtectionSee Explosion-proof Certification section



Explosion-proof Certification Details

This IQS900 model (A5 option) has passed multiple international explosion-proof certifications and is suitable for potentially explosive atmospheres.

Certification TypeApplicable AreaExplosion Protection MarkingCertificate NumberTemperature ClassAmbient Temperature Range
ATEX (Gas)II 3 G (Zone 2)Ex ec IIC T6/T5 GcLCIE 21 ATEX 1004 XT6-40°C ≤ Tamb ≤ +70°C




T5-40°C ≤ Tamb ≤ +85°C
IECEx (Gas)Ex ec IIC T6/T5 GcEx ec IIC T6/T5 GcIECEx LCIE 21.0005XT6-40°C ≤ Tamb ≤ +70°C




T5-40°C ≤ Tamb ≤ +85°C
CCSAus (Gas)Class I, Division 2, Groups A, B, C, DEx ec IIC T6/T5 GcCCSAus 80084516T6/T5Same as above

Class I, Zone 2, AEx ec IIC T6/T5 Gc



UKEX (Gas)II 3 G (Zone 2)Ex ec IIC T6/T5 GcCML 21 UKEX 4549 XT6-40°C ≤ Tamb ≤ +70°C




T5-40°C ≤ Tamb ≤ +85°C
KGS (Gas)Ex ec IIC T6/T5 GcEx ec IIC T6/T5 GcKGS 21-GA4BO-0355XT6-40°C ≤ Tamb ≤ +70°C




T5-40°C ≤ Tamb ≤ +85°C
EAC (Gas)2Ex e IIC T6/T5 Gc X2Ex e IIC T6/T5 Gc XEA3C RU C-CH.AAD07.B.03744/21T6-40°C ≤ Tamb ≤ +70°C




T5-40°C ≤ Tamb ≤ +85°C

Explosion-proof Installation Requirements:

  • IQS900 (A5) is only suitable for Zone 2 gas hazardous areas and Zone 22 dust hazardous areas.

  • The IQS900 must be installed in an industrial enclosure with at least IP54 ingress protection rating.

  • Cables entering the enclosure must use explosion-proof cable glands (such as SG1xx series).

  • The associated TQ402/TQ412 sensors and EA402 cables must use the A2 intrinsic safety explosion-proof version, suitable for Zone 0/1/2 areas.

  • The special conditions for safe use specified in the corresponding explosion-proof certificates must be strictly followed.

  • Power must be disconnected before any wiring or maintenance operations in hazardous areas.


Previous: 
Next: 

Quick Links

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
 WhatsApp: +8618106906650
 Email: sales2@exstar-automation.com / lily@htechplc.com
 Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.