IS200VAICH1C Analogon Input/Output Board designatus Electric Generalis (GE) ad Mark VI™ Imperium System. Haec tabula prima versio est in serie VAIC (inclusis omnibus versionibus usque ad VAICH1C et inclusis), praesertim in processu analogico signo acquisitionis et output adhibita. Pernecessarium est I/O moduli in gas Turbine et vaporis turbine systematum imperium.


Tabula IS200VAICH1C accipit 20 analogon inputs et imperium 4 analog outputs. Operatur in conjunctione cum duabus TBAI tabulis terminalibus, singulae 10 initibus et 2 outputibus comparantibus. Connexae per funes ad tabulam processus VAIC in eculeo VME positam, signa initus conditionata, multiplex et A/D convertuntur. Transferuntur deinde in backplanum VME ad VCMI tabulam et tandem ad moderatorem. Pro outputs, VAIC valores digitales ad currentes analogos convertit, onera externa per tabulas terminales impellens.


IS200VAICH1C subsidia tam simplicem quam triplicem applicationum modularem redundantem (TMR) sustinet. In configuratione TMR, initus signa in tabula terminali agitata tribus VME tormentis (R, S, T), singula continentes VAIC. Outputationes ad usum ambitum proprietarium impelluntur ubi omnes tres VAICs ad faciendum optatum usum conferunt. Si una tabula defecerit, reliquae duae tabulae ad rectam output venam producendam pergunt.


Ut ultima versio originalis generationis VAIC, IS200VAICH1C ab subsequentibus versionibus (ut VAICH1D) maxime differt facultatem in output depellendi: quando agens 20 mA outputs, maximum onus resistentiae 500 Ω sustinet (utendo 1000 ft of #18 filum). Operationem requirit cum TBAIH1B vel prioribus versionibus tabularum terminalium et etiam compatible cum omnibus emendationibus tabularum terminalium DTAI.


Tabula incorporat functiones diagnosticas comprehensivas, inter input limites compescit, vigilantia output, et status Nullam impedimenta, cum status indication per tabellam LEDs anterius. Accedit, firmware VAIC integumento gasi turbine compressoris equilis detectionis algorithms integrat, praecursores praecursores vigilantia in tempore reali ad 200 Hz scan- sarium et shutdown tutelam excitat intra 30 ms.



II. Praecipua functiones

Munera primaria IS200VAICH1C includunt, sed non limitantur ad sequentia:

1. Analog Input Acquisitionem

Tabula accipit 20 analogon inputs per duas TBAI tabulas terminales. Typi inputationes selectabiles sunt per jumpers in tabula terminali, sustinentes:

  • 4-20 mA current initus

  • ±1 mA input

  • ±5 V dc intentione input

  • ±10 V dc intentione input

Input circulos sonum suppressionis plumae, inter filtra ferraria et columellas configurabiles, columellas humiles transeuntes ad tuendum contra aestus et sonum altum frequentiam. Primae 10 inputationes (per J3 iungo) unum ferramentum colum-polium habent cum frequentia 500 rad/s continuas. Secundae 10 inputationes (per J4 connectoris) ferramenta colum columellae habent cum frequentiis intermissum 72 rad/s et 500 rad/s.

2. Analog Output Control

Tabula outputs praebet 4 analog. Duo figuntur in 4-20 mA, et alia duo configurari possunt pro 4-20 mA vel 0-200 mA. Circuitus output etiam strepitus suppressionis plumae utetur et technicam fabricationem patented redundantem: in systemata TM, unumquodque output per tres VAICs simul agitatur. Vena actualis outputa mensuratur cum seriei resistor, quae intentionem suam unicuique VAIC pascit. Output consequens est valor medianus trium currentium. Si tabula deficit, output eius hians est, et reliquae duae tabulae ad rectam output producendum pergunt.

3. Compressor Stall Deprehensio

Firmware VAIC includit gas turbines compressoris stabuli detectionis functionalitatis, primas quattuor analogas initibus 200 Hz intuens. Duo algorithms selectabiles praesto sunt:

  • Small LM Gas Turbine Algorithmus: Duobus pressionis transducers utitur.

  • Gravis-Officium Gas Turbine Algorithmus: utitur tribus pressionibus transductoribus.

Algorithmus monitores compressor pressionis emissionis (PS3) eiusque mutationis (dPS3dt), comparans parametris (KPS3 constantibus) ut praesepio immineat determinare. Semel utitur, VAIC signum itineris exit intra 30 ms, moderatorem efficiens ut omnes escas valvulas clausulas intercludant (FSOVs).

4. Input / Output signum condicionibus

Omnes canales input et output instructi sunt insignibus circuitibus condicionibus, incluso eliquatione, amplificatione et solitudine. Initibus utendum est 16-bit A/D convertentis cum solutione 14 frenum, accurate mensuras assequendas melius quam 0.1% plenae scalae. Outputs uti 12 frenum D/A converter cum 0.5% accuratione.

5. Grand Diagnostics et Sui Test

Tabula lineamentorum diagnostica munera comprehendens;

  • Singulis analog initus hardware modum reprimendi habet (praeset non-configurable high/low levels near the ends of the operating range). His limitibus excedens, claudit canalem illum scandentem et terrorem diagnosticam compositam gignit, L3DIAG_VAIC.

  • Uniuscuiusque initus habet modum systematis software configurabile compescendi, qui adhiberi potest ad terrores gignendos et sicut latrunculos vel non latlingos conformatus.

  • In TMR systemata, unumquodque initus signum monitorium est ad declinationem a valore mediano. Praesens modus superans culpam generat, praenuntia praenuntia de canali potentiale difficultates.

  • D/A outputs, excursus outputus, summa currentis, suicidium dispositos, et 20/200 mA dispositos scandendo ad rationem monitores sunt.

  • ID fabrica in tabula terminali ab VAIC interrogetur. A mismatch hardware repugnantia culpa generat.

6. Status indicium

In fronte tabulae notae tres indices duxerunt:

  • RUN (Green): Micat per normalem operationem.

  • FAIL (Red): Stabilis in tabula defectum indicat.

  • STATUS (Orange): stabilis illustrat cum conditio diagnostica terroris existit (normaliter off).



III. Systema Applications

1. Application in Mark VI Imperium System

nucleus IS200VAICH1C est nucleus analogi I/O in tabula processus in Mark VI systematis imperium, late in usu processus turbinis gas turbinis et vaporis ditionis, tutelae et vigilantiae. Partes eius intra systema comprehendunt:

  • Processus Parameter Acquisitionem: Acquirit analoga signa a sensoriis mensurandi temperiem, pressuram, fluxum, velocitatem, etc., convertens eas ad valores digitales ad usum a moderatore.

  • Actuator control: Outputs 4-20 mA vel 0-200 mA annuit ut valvulae positiones pellant, valvulae servo, variae frequentiae impulsus, et alii actuatores.

  • Stall Protection: Monitor compressor pressionis in real-time tempore detegit, praecursores stabuli celeriter detegit, et triggers subitis shutdown ut turbomachinam defendat.

  • Superuacua I/O: In TMR systemata triplicem superuacentem analogum initibus et outputibus praebet, operationis systematis infectis ab uno puncto delictis praestans.

2. Simplex et TMR Ratio configurationum

Simplex System: uno IS200VAICH1C tabula utitur et duabus TBAI tabulis terminalibus. Input signa directe connexa sunt, et outputs ab uno VAIC adiguntur.

Ratio TMR: Utitur tribus tabulis IS200VAICH1C (in R, S, T tormentis respective) et duabus TBAI tabulis terminalibus. Input signa in tabula terminali ad tria tormenta parallelo agitata sunt. Outputs nugationem median-selectae utuntur, cum singulis VAIC portionem hodiernae conferentes. Totalis output est media trium. Si una tabula deficiat, reliqua duo statim praetereantur.

3. Typicam Application missiones

  • Gas Turbine Imperium: Compressor diverticulum rector vane imperium, cibus imperium, temperatura magna vigilantia, stabulum praesidium.

  • Vapor Turbine Imperium: Praefectus valvae imperium, pressura vapor / temperatus vigilantia.

  • Generator Excitatio: Excitatio voltage/current vigilantia.

  • Processus Industrialis Imperium: Acquisitio et Potestatio pressurae, fluxus, gradus, etc.



IV. Detailed interface Description

1. Terminatio Board Interface

IS200VAICH1C coniungit cum duabus TBAI tabulis terminalibus per duas funes 50-pinos connexiones (J3 et J4). Quaelibet tabula terminalis 10 initibus et 2 outputibus praebet. Jumpers in tabula terminali selige input genus (current/voltage) et range output (20/200 mA).

2. Backplane Interface

Tabula communicat cum tabula VCMI et aliis chartis per VME iungo cinematographico, data inputa tradenda et mandata recipienda. Backplanum etiam praebet potestatem 24 V dc transmittendis externis posse (per tabulam terminalem).

3. Front Panel Indicatores

LED Color Normal publica abnormes publicae
RUN Viridis Micans Off vel stabilis in tabula indicat non currit
DELICTUM Red Off Stabilis in tabula defectum indicat
QUID Orange Off Stabilis super indicat diagnostica terror existit

4. Function interface

Delineatio diagnostica enucleata, incluso limite status cuiusque canalis input, output valores currentes, status Nullam et deviationes tmr, legi potest per programmatum Instrumentorum.



V. Diagnostica et sustentationem

1. Functions Diagnostica List

Culpa Code Description possibilis causa
2 CRC defectum memoria mico Firmware programming error (tabula non online)
3 CRC defectum primi ante activae Firmware errorem sed tabula permisit online
16 Ratio modus reprehendo is disabled Ratio reprehendo erret configuratione
17 Tabula ID deficiendi Defecit ID chip in VME I / O tabula
18 J3 ID deficiendi Defecit ID chip in J3 iungo aut funis problema
19 J4 ID defectum Defecit ID chip in J4 iungo aut funis problema
24 Firmware / odio repugnantia Terminatio connexa tabula genus non praebetur
30-31 Mando / IO compat codice mismatch tre lima repugnat firmware
32-65 Analog input [#] pestilens Virtus culpa transducor, malus transducor, apertus vel brevis circuitus
66-69 Output [#] singula vena nimis alta Tabula defectum
70-73 Output [#] summa vena variatur ex reference Tabula defectum vel aperta onus
74-77 Output [#] referat current error D / A convertentis defectum
78-81 Output [#] vena singula insalubris Simplex modus current ex terminis
82-85 Nullam non-muneris suicide Nullam vel ultrices elit
86-89 Output [#] 20/200 mA lectio non-functionalis Configurationis non congruit Nullam feedback
90-93 Output [#] mortem activae TMR systema output unius tabulae disiuncta
94-95 J3/J4 tabula terminali repugnat config Nefas terminus tabula genus
128-223 Signum Logicae [#] suffragii mismatch Signum initus recedit a medianis
224-249 Signum initus # suffragatio mismatch Deviat a mediano plus quam TMR Diff Limit

2. Sustentacionem Commendatione

  • Regulariter reprehendo diagnostica terrores per Toolbox et anomalias oratio prompte.

  • Curare tabulam terminalem jumpers actui generum sensoriis aequare.

  • In TMR systemata, status LEDs in singulis tabulis monitor et tabulas vitiosas prompte substitue.

  • Attende convenientiam cum reponentes tabulas: VAICH1C uti debet TBAIH1B vel ante terminales tabulas.



VI. Compressor Stall Deprehensio

1. Algorithmus Overview

Firmware VAIC duo algorithms deprehensio stabulo includit, quattuor primas initibus 200 Hz intuens:

  • Parvus LM Gas Turbinus Algorithmus: duobus pressionis transducentibus (eg, PS3A, PS3B).

  • Gravis-Officium Gas Turbine Algorithmus: utitur tribus pressionibus transducentibus (eg, PS3A, PS3B, PS3C).

Algorithmus monitores compressor pressionis missionis (PS3) eiusque mutationis (dPS3dt) comparans parametris stabuli configurabilis. Parametri includit:

Variabilis Description
PS3I Coepi PS3 valorem
KPS3_Drop_S Versus ad PS3I versus dPS3dt
KPS3_Drop_I Intercipe lineam pro PS3I versus dPS3dt .
KPS3_DROP_Mn Minimum valorem pro PS3I versus dPS3dt
KPS3_DROP_Mx Maximum valorem pro PS3I versus dPS3dt
KPS3_Delta_S Clivus versus ad PS3I versus Delta PS3 drop
KPS3_Delta_I Intercipe lineam pro PS3I versus Delta PS3 drop
KPS3_Delt_Mx Maximum valorem pro PS3I versus Delta PS3 drop

2. Triggering et Praesidium

Cum algorithmus praecursorem praesepe deprehendit, VAIC signum itineris compressoris praesepii (CompStall) intra 30 ms. Hoc signum moderatori mittitur ut omnes escas valvulas clausulas (FSOVs) intercludant, subitis shutdown foveant. Sensus deprehensionis stabuli per conformationem ambitum adaptari potest.



VII. Compatibilitas et configurationis

1. Terminatio Board Compatibility

IS200VAICH1C ad generationem originalem VAIC pertinet et cum sequentibus tabulis terminalibus adhiberi debet:

  • TBAIH1B vel antea (eg, TBAIH1A);

  • DTAI aliqua revision

Repugnant tabulae terminales: TBAIH1C et postea (haec destinantur VAICH1D, onera superiora sustinentes).

2. Configurationis Methodi

  • Input genus electum per jumpers in terminalis tabula.

  • Output range (20/200 mA) delecti per tabulas terminales jumpers.

  • Parametri deprehensio stallae, systematis limites, deviationis TMR limites, etc., per programmatum instrumentorum instrumentorum configuratum.

  • Filtrum parametri, terror dat, etc., etiam per programmatum conformatus.

3. Firmware et Hardware eu

Id chip in tabula promptuarium in tabula speciei et informationis revisionis, lege a systemate ad convenientiam hardware curandi. Cum tabulam reponat, exemplar numerus compositus comprobabit et lima configurationem (tre lima) aequare versioni firmware.


Item Specification
Exemplar Number IS200VAICH1C
Product Name Analog Input / Output Board
Compatible System Mark VI™ Gas Turbine/Steam Turbine Control System
Tabula Series VAIC (Analog Input/Output)
Versionem Information Ultima versio generationis originalis (includit VAICH1C et omnes versiones praecedentes)
Summa canales 24 canales (20 inputs + 4 outputs), duos tabulas terminales requirit
Numerus potenti canales 20 (10 per terminal tabula)
Input Genera 4-20 mA, ±1 mA, ±5 V dc, ±10 V dc.
Input Impedimentum 250 Ω (4-20 mA), 5,000 Ω (±1 mA), 500,000 Ω (voltage inputs)
Input Converter 16-bit A/D, 14-bit resolutio
Input Scan Tempus Normalis scan 10 ms (100 Hz); primum IV inputs configurable ad CC Hz scan
Input mensurae Accuracy Melius 0,1% of scale
Sonitus initus suppressio Primum 10 circuitus (J3): ferramenta colum unius poli, D rad/s frange; Secundus circuitus X (J4): ferramenta duo-polus sparguntur, abrumpitur ad 72 et 500 rad/s; Filtrum Software: Configurable duo-polus humilem trans- colum, optiones 0, 0,75, 1.5, 3, 6, 12 Hz
Communis modus reprobationis AC CMR 60 dB @ 60 Hz (modus communis intentionis usque ad V ±); DC CMR 80 dB (modus communis intentionis -5 ad +7 V cacumen)
Communis Modus Voltage Range ±5 V (±2 V pro ± 10 V initibus)
Numerus output canales 4 (2 tabula per terminal)
Output Genera 2 fixum 4-20 mA, 2 selectable 4-20 mA vel 0-200 mA
Output Converter 12-bit D/A, accurate 0.5%
Output Load Capability 4-20 mA output: max D Ω (utendo filum 1000 ft #18); 200 mA output: max 50 Ω
Output dundantia Methodo In systematis TMR, tres VAICs simul concutiunt, output est valor medianus; defecit tabula statim disiungitur
Virtus Consummatio Minus quam XXXI W
Compressor Stall Deprehensio Deprehensio tempus ≤ 30 ms, triggers Nullam output
Culpa Deprehensio functiones Input out-of-limites, output anomaliae, vitia nulla, tmr signum declinationis, ID chip mismatch, etc.
Front Panel LEDs CURSUS (Green mico), FAIL (Red stabilis), STATU (Orange stabilis ad terrorem)
Terminal Boards compatible TBAIH1B vel ante, vel recognitio tabularum terminalium DTAI (non compatitur cum TBAIH1C vel STAI)
Dimensiones 26.04 cm altum 1.99 cm latum × 18.73 cm altum (10.26 in 0,782 in 7.375 in)
Temperature operating 0 ad 60°C (32 ad 140°F)
Adscendens Methodus VME eculeo obturaculum-in card
Testimonia Meets GE Industrial Control Systems standards

Priora: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephono: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
: Email   sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.