nyban1
Hic es: Home » Systems » Sensus Ratio » 3300XL 8mm Propinquitas Transducer System » 330101-00-08-10-02-05 Eddy Current Probe
Relinque nobis Nuntius

loading

330101-00-08-10-02-05 Eddy Current Probe

  • Bently Nevada

  • 330101-00-08-10-02-05

  • In Stock

  • T/T

  • Xiamen

Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
telegraphum sharing button
sharethis sharing button

330101-00-08-10-02-05 est Benly Nevada 3300 XL series vexillum currente torrens probe cum tota longitudine 1.0 metri (3.3 pedes) . Hoc exemplar super bases conformationis (stamina 3/8-24 UNF, 0.0‑inch longitudinis, 0,8‑inch causa longitudinis, vexillum ClickLoc iungo et cables vexillum) addendo CSA, ATEX, et IECEx approbationibus ancipitis areae , aptam reddens institutiones in atmosphaeras explosivae.

Hoc specillum typice adhibetur cum 3300 XL area ancipitia probata extensionis funis (eg, 330130-040-00-05) et 3300 XL area ancipitia approximata Sensorem (exempli gratia Eius 1.0 m longitudo tota specimen applicationum est ubi Sensor Proximitor in area tuta vel clausura probata annectitur, dum specillum in Zona 0, Zona 1, vel Zona 2 ancipitia areas inauguratur.

Exemplar Naufragii: 330101-00-08-10-02-05 Configurationis Details

Sequentes Bently Nevada partem numeri systematis coding (referunt ad paginas notas 13-14), agri in hoc exemplari numerum sequentem repraesentant:

Agro

Code

Parameter

Descriptio

Basis Model

330101

3300 XL 8 mm Probe, 3/8-24, UNF filo, sine armis

Compatible cum 3300 XL 8 mm et 3300 5 mm systemata

Longitudo Unthreaded (A)

00

0.0 pollices

Longe a specillo ad apicem usque ad sequelam committitur; brevissimum configuratione

Longitudo altiore Causa (b)

08

0.8 pollices

Tota staminea longitudinis; vexillum causa brevis

Totalis Longitudo Bene (C)

10

1.0 meter (3.3 ft)

Specillum totalis longitudo fune (including iungo)

Connector & Cable Option (D)

02

Minature coaxial ClickLoc iungo vexillum cable

Latin FEP‑insulated funem, inauratum ClickLoc iungo

Agency Approbatio (E)

05

CSA, ATEX, IECEx Periculosam Area Approbationes

Certificavit per se tutum officinae in atmosphaerae explosivae

Clavis Configurationis Nota : Hoc exemplar a differt 330101-00-08-10-02-00 tantum in optione approbationis ( 05 pro 00). Praecipue destinatur locis ancipitia, occurrens ATEX, IECEx, et CSA intrinseca salus requisita ad usum in Zona 0, Zona 1, Zona 2, et Classis I, II, III locorum ancipitia.

Periculosam Area Approvals & Conditionibus Tutus Usus

Ancipitia Area certificaciones

330101-00-08-10-02-05 approbationes ancipites sequentes defert, aptas institutiones in regionibus maioris industrialibus in toto orbe:

Certification

Type

Area Classification

Temperature Classis

ATEX/IECEx

Ex ia IIC T4/T5 Ga

Zona 0, 1, 2

T5 @ Ta = -55°C ad +40°C
T4 @ Ta = -55°C ad +80°C

cNRTLus

Classis I, Zona 0, AEx/Ex ia IIC T4/T5 Ga

Classis I, Societates A, B, C, D,
Classis II, Societates E, F, G
Classis III

Sicut supra

Praeterea specillum etiam tutelae ignitionis cineris ATEX/IECEx occurrit (Ex ia IIIC T90°C ... T280°C Dc). Referre ad schedae Paginae 12 schedula temperatura pro certis classibus temperaturas ambiente temperatura subnixa.

Conditionibus Tutus Usus (Per se Tutus Systems)

Cum ratio intrinsece tuta adhibeatur, condiciones sequentes servari debent;

  • Claustra/Isolatores : Instrui debent per se tuta claustra Zener per Bently Nevada trahentem 141092, vel cum isolatoribus galvanicis.

  • Entity Parameters (cum annexis ad probatum Proximitorem Sensorem);

    • Ui = -28V

    • Ii = 140 mA

    • Pi = 0.91 W

    • Ci = 47 nF

    • Li = 1460 μH

  • Installation Environment : Proximitor Sensor institui debet in area non periculosa vel intra clausuram probationis approbatae explosionis.

  • Systema Integrity : Specillum, funis extensio, sensor proximus, et quilibet protectores iungentium omnes eandem aream ancipitia approbationis rating portare debent. Mixtio non-probatorum partium certificationem evacuabit.

Maximus : Hoc specillum adhibendum est cum area ancipitia approbata extensionis funis (eg, 330130-040-00-05) et Sensor Proximitoris (eg, 330180-50-05) ad systema tutum intrinsece integrum conservandum.

Applicationem Missiones & Electio Guide

330101-00-08-10-02-05 apta est ad applicationes typicas sequentes:

  1. Vexillum 5‑Meter IS System Configurationis : Paired cum 4.0 m area ancipitia probata extensionis fune (eg, 330130-040-00-05) et 5 m area ancipitia approximata Sensorem (eg, 330180-50-05) formare integram 5‑metri IS vigilantiam, idealem cum Proximitor Sensor in area tutissima et specillum in area ancipitia inauguratur.

  2. Vibratio radialis vigilantia in locis Hazardois : Pro vecte vibrationis mensurae in compressoribus, vaporibus turbines, generantibus, et soleatus in locis Zonae 0/1/2 sita, ut refinerias, plantas petrochemicas et facultates gasi naturales.

  3. Axial Position (Thrust) Monitoring in Area Hazardous : adhiberi potest ut positio axialis metiri rotor et monitor clavum gerens indumentum, occurrens API 670 requisita ad positionem vigilantiam.

  4. Keyphasor / Speed ​​Mensurae in locis Periculosis : Keyphasor potest esse ut specillum praebeat velocitatem signa referentia ad systematum tutelae transeundum (referes ad notas applicationes pertinentes).

  5. Apta IIC Gas Group : Hoc specillum idoneum est in ambitus periculosissimos continentes hydrogenii, acetylenae, carbo disulfidentium, et aliorum IIC coetus gasorum.

Notae selectae :

  • Totalis Longitudo Matching : Probe longitudo + Extensio fune longitudinis = Proximitor Sensor longitudinis totius systematis (5 m vel 9 m). Hoc 1.0 m specillum adhibendum est cum 4.0 m area ancipitia probata extensionis funem ad formandum systema 5 metri IS.

  • Temperature Classis Electio : Elige T4 vel T5 in temperatura ambientium. T5 (-55°C ad +40°C) est pro temperaturis ambientibus inferioribus; T4 (-55°C ad +80°C) latius patet.

  • Thread Installation : 3/8-24 UNF threads. Sequela certaminis longitudo non excedere debet 0.563 digitorum ad institutionem difficultatem vitandam vel damnum explorandum.

  • Longitudo Unthread : Hoc exemplar habet longitudinem 0.0‑inch. Si foramen tuum adscendens umerum internum habet, aut specillum extremum ad certum spatium extendendum opus est, exemplar elige cum longiore prolixiore longitudine.

  • Ambiens Temperature : Latin probe aestimatur +177°C. Si applicatio hanc temperiem excedit, elige ETR summus temperatura ancipitia aream probatam specillum (series 330191/330192 cum approbatione optionis 05).

  • Tutela armata : Si funis subiacebit damno mechanico (contritionis, abrasioni), electo aream ancipitalem ancipitem probatum specillum (eg, 330102-00-08-10-02-05).

  • Connector Praesidium : In locis ancipitibus, protectores connectentes (ordine separatim, ad usum ancipitia areae aptum) enixe commendantur ne oleum caligo vel umor ingressa et intrinsecam salutem signandi integritatem teneant.

Mechanica Dimensiones & Installation

  • Probabile consilium Diametri : 8.0 mm (0.31 in)

  • Thread Specification : 3/8-24 UNF-2A; commendatur lock nucis torques: 11.2 N·m (100 in·lbf)

  • Longitudo altiore casu : 0.8 in (20.3 mm)

  • Longitudo Unthread : 0.0 in

  • Cable diametri exterioris : 3.68 mm (0.145 in) maximum

  • Connector Diameter exterior : 7.24 mm (0.285 in) maximum

  • Radius Bend minimum : 25.4 mm (1.0 in)

  • Installation Drawing : Intrinsecus tutae institutionis systematis stricte sequi debet Bently Nevada drawing 141092, inter impedimentum delectu, fundatio, et exercitia wiring.

  • Apicibus instruitur : Ante institutionem filis foveam inspice ad munditiem et ad profunditatem debitam. Utere nuce suadeo (parte numero 04301007) et adstringe torques certos. Lacunam specillum ad -9 Vdc (approx. 1.27 mm) constitue, quod per Proximitorem Sensorem output intentionis viverra potest. In locis ancipitibus omnes operationes implere debent cum signis praesidiis explosionis pertinentibus (eg, IEC 60079-14).

Related Products & Compatible configurationis

Hoc specillum typice adhibetur cum sequenti area ancipitia probata producta:

Socius Product

Commendatur Model

Descriptio

Extensio Cable

330130-040-00-05

4.0 m vexillum ancipitia area remulco, formas 5 m systematis IS

Proximor Sensor

330180-50-05

V m systema panel‑mons ancipitia area Proximitoria

Lock Nut

04301007

3/8-24 cincinno nut cum salute filum foraminibus (nullum approbatione requiritur)

Adscendens Bracket

137492-01

Aluminium staminea bracket adscendens, stamina 3/8-24 (nulla approbatione requisita)

Connector Protector

40180-02 (vel 40113-02)

Connector protector ornamentum, locis ancipitia commendatur

Ad alias figurationes, refer ad sequentia ancipitia area optiones exploratoria probata;

Exemplar

Thread

Longitudo Unthreaded

Causa Longitudo

Summa Longitudo

Armor

Approbationes

Applicationem

330101-00-08-10-02-05

3/8-24

0.0'

0.8'

1.0 m

No

ATEX/IECEx

Exemplar Current, basic ancipitia area configuratione

330101-00-12-10-02-05

3/8-24

1.2'

0.8'

1.0 m

No

ATEX/IECEx

Ancipitia area, longitudo longior requiritur

330101-00-08-05-02-05

3/8-24

0.0'

0.8'

0.5 m

No

ATEX/IECEx

Tota longitudo brevissima, paria cum fune pro 9 m IS systematis 8.5 m

330102-00-08-10-02-05

3/8-24

0.0'

0.8'

1.0 m

Ita

ATEX/IECEx

Periculosam area cum armato mechanica praesidio

330103-00-??-10-02-05

M10×1

Quod erat faciendum

Quod erat faciendum

1.0 m

No

ATEX/IECEx

Metric linum ancipitia area probe

Matching Extensio Cable : Hoc specillum adhibendum est cum 4.0 m area ancipitia probata extensionis fune (eg, 330130-040-00-05) ad completam 5‑metri IS rationem.

Inquisitionis & Technical Support

330101-00-08-10-02-05 est exemplar areae ancipitiae vulgariter instructum in linea producti Bently Nevada. Nam cursus sapien, tempus plumbi, vel technicae picturae, pete nobis contactum:

  • Online Inquisitionis : 'Place a Quote' button et praebe exemplum numeri promptae responsionis.

  • Technical Support : Si adiumento opus est comprobando an haec configuratione tua ancipitia areae institutionis requisita occurrat, sis anceps area classificationis (Zone/Divisionis), coetus gasi, genus temperatus, et situs temperatus ambiens, et certificationem parametri et systematis integritatem confirmabimus.

Specification

Precium

Probe consilium Diameter

8.0 mm (0.31 in)

Post Specification

3/8-24 UNF-2A

Longitudo Unthreaded

0.0 in (0 mm)

Longitudo altiore Causa

0.8 in (20.3 mm)

Totalis Longitudo (including cable)

1.0 meter (3.3 ft)

Cable Type

75Ω triaxiale, FEP velit, cable vexillum

Connector Type

Miniature coaxial ClickLoc patella iungo (masculum)

Linearibus dolor

2 mm (80 mils), ex approx. 0.25 mm (10 mils) ad 2.3 mm (90 mils)

Output intentione dolor

Proxime. -1 Vdc ad -17 Vdc (super lineari range)

Commendatur aculeis vibrationis Gap Voltage

—9 Vdc [proxime. 1.27 mm (50 mils)]

Incremental Scale Factor (ISF)

7.87 V/mm (200 mV/mil) ± 5% (including vicissitudinem errorum, 0°C ad +45°C)

Digredior a recta linea (DSL)

<±0.025 mm (±1 mil) (0°C ad +45°C, 1 m systematis)

Temperature dolor (Probe)

-52°C ad + 177°C (-62°F ad +350°F)

Probabile consilium Material

Polyphenylene sulfide (PPS)

Probe Casus Material

AISI 303 vel 304 immaculatam ferro

Minimum Target Diameter

15.2 mm (0.6 in) scopo plano

Minimum commendatur Shaft Diameter

76.2 mm (3 in) (vibrationis radialis)

Frequentia Responsio

0 ad 10 kHz, +0, -3 dB (cum usque ad 305 m agri wiring)

Distrahens fortitudo

Probe causa ad cable: 330 N (75 lbf) maximum aestimavit

330101 (3)

Previous: 
Next: 

Velox Vincula

PRODUCTS

OEM

Contact Us

 Telephone: +86-181-0690-6650
whatsapp  : LXXXVI 18106906650
Email  :  sales2@exstar-automation.com / lily@htechplc.com
Oratio  : Locus 1904, Aedificium B, Diamond Coast, No. 96 Lujiang Road, Siming Districtus, Xiamen Fujian, China
Copyright © 2025 Exstar Automation Services Co., Ltd. All Rights Reserved.